Tri-axial plantar pressure sensor: Design, calibration and characterization

被引:0
作者
Heywood, EJ [1 ]
Jeutter, DC [1 ]
Harris, GF [1 ]
机构
[1] Marquette Univ, Dept Biomed Engn, Milwaukee, WI 53233 USA
来源
PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7 | 2004年 / 26卷
关键词
capacitor; gait; instrumentation plantar pressure; sensor; shear; transducer;
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A novel tri-axial plantar pressure sensor has been developed. This sensor simultaneously measures vertical plantar pressure and anterior-posterior and medial-lateral shear plantar pressures utilizing a central post, four parallel plates, and a commercial miniature pressure transducer. As a subject walks over the sensor, the central post is deflected and the shear pressures are measured utilizing capacitive sensing technology. The miniature pressure transducer (MPT) is simultaneously loaded to measure the vertical pressure. Each individual tri-axial plantar pressure sensor has the capability of measuring shear forces ranging from 0 to 15 N and vertical pressures ranging from 0 to 28 MPa. The shear component of the tri-axial pressure sensor has a sensitivity of 1.3 mV/g, a non-linearity of 8.3%, and hysteresis of 7.3%. The commercial vertical MPT has a sensitivity of 220 nv/V/psi, a non-linearity of 0.094%, and a hysteresis of 0.567%. An array of individual tri-axial plantar pressure sensors in the form of a platform win be developed to measure plantar pressure in patients. This pressure platform is placed on the surface of a walkway and is suitable for barefoot walking trials.
引用
收藏
页码:2010 / 2013
页数:4
相关论文
共 12 条
  • [1] ABUZZAHAB FS, 1995 IEEE EMBC CMBEC, P1271
  • [2] In-shoe biaxial shear force measurement: The Kent shear system
    Akhlaghi, F
    Pepper, MG
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1996, 34 (04) : 315 - 317
  • [3] VERTICAL FORCES ACTING ON THE FEET OF DIABETIC-PATIENTS WITH NEUROPATHIC ULCERATION
    CTERCTEKO, GC
    DHANENDRAN, M
    HUTTON, WC
    LEQUESNE, LP
    [J]. BRITISH JOURNAL OF SURGERY, 1981, 68 (09) : 608 - 614
  • [4] A device for simultaneous measurement of pressure and shear force distribution on the plantar surface of the foot
    Davis, BL
    Perry, JE
    Neth, DC
    Waters, KC
    [J]. JOURNAL OF APPLIED BIOMECHANICS, 1998, 14 (01) : 93 - 104
  • [5] A study of in-shoe plantar shear in normals
    Hosein, R
    Lord, M
    [J]. CLINICAL BIOMECHANICS, 2000, 15 (01) : 46 - 53
  • [6] KOULAXOUZIDIS AV, 2000, 22 ANN EMBS INT C CH
  • [7] THE DEVELOPMENT OF THE LOW PROFILE LIVERPOOL SHEAR TRANSDUCER
    LAING, P
    DEOGAN, H
    COGLEY, D
    CRERAND, S
    HAMMOND, P
    KLENERMAN, L
    [J]. CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 (02): : 115 - 124
  • [8] Lebar A M, 1996, IEEE Trans Rehabil Eng, V4, P310, DOI 10.1109/86.547932
  • [9] METHOD FOR IN-SHOE SHEAR-STRESS MEASUREMENT
    LORD, M
    HOSEIN, R
    WILLIAMS, RB
    [J]. JOURNAL OF BIOMEDICAL ENGINEERING, 1992, 14 (03): : 181 - 186
  • [10] FORCES UNDER THE FOOT
    POLLARD, JP
    LEQUESNE, LP
    TAPPIN, JW
    [J]. JOURNAL OF BIOMEDICAL ENGINEERING, 1983, 5 (01): : 37 - 40