Quantification of piperazine phosphate in human plasma by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry employing precolumn derivatization with dansyl chloride

被引:19
作者
Lin, Hui [1 ,2 ]
Tian, Yuan [1 ,2 ]
Zhang, Zunjian [1 ,2 ]
Wu, Lili [3 ,4 ]
Chen, Yun [3 ,4 ]
机构
[1] China Pharmaceut Univ, Ctr Instrumental Anal, Nanjing 210009, Peoples R China
[2] China Pharmaceut Univ, Key Lab Drug Qual Control & Pharmacovigilance, Minist Educ, Nanjing 210009, Peoples R China
[3] Chinese Acad Med Sci, Inst Dermatol, Nanjing 210042, Peoples R China
[4] Perking Union Med Coll, Nanjing 210042, Peoples R China
关键词
Piperazine phosphate; Derivatization; Liquid chromatography-tandem mass spectrometry; Bioequivalence;
D O I
10.1016/j.aca.2010.02.003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes a novel method that combines dansyl chloride (DNS-CL) derivatization with high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS) for the sensitive and selective determination of piperazine phosphate in human plasma. After addition of ondansetron hydrochloride as internal standard (IS), piperazine phosphate was derivatized and then extracted with ethyl acetate. After being evaporated and reconstituted, the sample was analyzed using LC-ESI/MS/MS. Separation was achieved using an Agilent ZORBAX SB-C-18 (150 mm x 2.1 mm I.D., 3.5 mu m) column and isocratic elution with 10 mM ammonium acetate solution (pH 3.0)-methanol (50: 50, v/v). Detection was performed on a triple-quadrupole mass spectrometer utilizing electrospray ionization (ESI) interface operating in positive ion and selected reaction monitoring (SRM) mode with the precursor to product ion transitions m/z 320 -> 171 for DNS-CL-piperazine phosphate and m/z 294 170 for the IS. The method was fully validated for its selectivity, sensitivity, linearity, precision, accuracy, recovery, matrix effect and stability. The coefficient (r) of piperazine phosphate with a linear range of 0.1-15 mu g mL(-1) was 0.9974-0.9995. The limit of detection and lower limit of quantification in human plasma were 0.01 and 0.1 mu g mL(-1), respectively. The validated LC-ESI/MS/MS method has been successfully applied to a bioequivalence study of piperazine phosphate trochiscus in Chinese healthy male volunteers. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:40 / 48
页数:9
相关论文
共 29 条
[1]  
ABOUOUF AM, 1979, J ASSOC OFF ANA CHEM, V5, P1138
[2]  
BAGGI TR, 1974, J ASSOC OFF ANA CHEM, V5, P1144
[3]  
BELAL S, 1981, J PHARM SCI, V2, P127
[4]  
BOND GR, 1960, ANAL CHEM, V10, P1332
[5]  
DESSOUKY YM, 1974, ANALYST, V181, P482
[6]  
ELSHABOURI SR, 1987, TALANTA, V11, P968
[7]  
GOODWIN LG, 1958, BRIT MED J, V5063, P131
[8]  
GOODWIN LG, 1958, BRIT MED J, V5063, P135
[9]  
GOODWIN LG, 1958, BRIT MED J, V5063, P133
[10]  
HANNA S, 1973, J PHARM SCI, V12, P2024