A mechanical comparison and review of transverse, step-cut, and sigmoid osteotomies

被引:29
作者
Cascio, BM
Thomas, KA
Wilson, SC
机构
[1] Johns Hopkins Univ, Sch Med, Dept Orthopaed Surg, Baltimore, MD USA
[2] Macropore Inc, San Diego, CA USA
[3] Tulane Univ, Sch Med, Dept Orthopaed Surg, New Orleans, LA 70112 USA
关键词
D O I
10.1097/01.blo.0000069895.31220.e8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Successful incorporation of massive allografts for the treatment of bone deficiency demands maximizing biologic and mechanical factors. These factors have yet to be mastered, as evidenced by the 8% to 17% nonunion and the 5% to 20% fracture rate. The current study addresses the allograft incorporation process by examining the three construct geometries: transverse, step-cut, and sigmoid. Specimens were plated and mounted on a mechanical testing machine. A rotational displacement was applied, and torsional stiffness (N-m/degrees), maximum torque (N-m), and maximum displacement (degrees) were calculated. The sigmoid osteotomies had a torsional stiffness of 1.90+/-0.68 N-m/degrees and maximum torque of 18.85+/-6.63 N-m versus 0.99+/-N-m/degrees and 14.48+/-2.15 N-m for the transverse osteotomies; and a maximum angular displacement of 11.60degrees+/-1.78degrees versus 5.73degrees+/-1.6degrees for the step-cut osteotomies. The step-cut osteotomies consistently failed at the step-cut corners, which acted as stress risers. Computer-aided solid modeling of the contact surfaces showed that the step and sigmoid osteotomy areas were 74% and 44%, respectively, larger than the transverse osteotomy. The sigmoid osteotomy, created with a template and pneumatic drill, seems to offer a mechanical advantage over the transverse and step-cut osteotomies by increasing stability and contact surface area relative to the transverse osteotomy but reducing the stress-riser effect of the step-cut osteotomy.
引用
收藏
页码:296 / 304
页数:9
相关论文
共 23 条
[1]  
Aro H T, 1991, J Orthop Trauma, V5, P351, DOI 10.1097/00005131-199109000-00016
[2]  
ARO HT, 1993, CLIN ORTHOP RELAT R, P8
[3]   FRACTURES OF ALLOGRAFTS - FREQUENCY, TREATMENT, AND END-RESULTS [J].
BERREY, BH ;
LORD, CF ;
GEBHARDT, MC ;
MANKIN, HJ .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (06) :825-833
[4]   Influence of size and stability of the osteotomy gap on the success of fracture healing [J].
Claes, L ;
Augat, P ;
Suger, G ;
Wilke, HJ .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1997, 15 (04) :577-584
[5]   The use of allografts in orthopaedic surgery part I: The use of allografts in musculoskeletal oncology [J].
Dion, N ;
Sim, FH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (04) :644-654
[6]   TORSIONAL STRENGTH REDUCTION DUE TO CORTICAL DEFECTS IN BONE [J].
EDGERTON, BC ;
AN, KN ;
MORREY, BF .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1990, 8 (06) :851-855
[7]   Retrieved human allografts - A clinicopathological study [J].
Enneking, WE ;
Campanacci, DA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (07) :971-986
[8]   Long-term follow-up of patients with osteochondral allografts - A correlation between immunologic responses and clinical outcome [J].
Friedlander, GE ;
Strong, DM ;
Tomford, WW ;
Mankin, HJ .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 1999, 30 (04) :583-+
[9]   EFFECTS OF INSTABILITY ON BONE HEALING - FEMORAL OSTEOTOMIES STUDIED IN RATS [J].
GRUNDNES, O ;
REIKERAS, O .
ACTA ORTHOPAEDICA SCANDINAVICA, 1993, 64 (01) :55-58
[10]  
Hornicek FJ, 2001, CLIN ORTHOP RELAT R, P87