Model updating of Masonry courtyard walls of the historical Isabey mosque using ambient vibration measurements

被引:14
作者
Ozcelik, Ozgur [1 ]
Misir, Ibrahim Serkan [1 ]
Yucel, Umut [2 ]
Durmazgezer, Erkan [3 ]
Yucel, Gokhan [4 ]
Amaddeo, Carmen [5 ]
机构
[1] Dokuz Eylul Univ, Civil Engn Dept, TR-35390 Izmir, Turkey
[2] Nevsehir Haci Bektas Veli Univ, Civil Engn Dept, TR-50300 Merkez, Nevsehir, Turkey
[3] Izmir Kavram Vocat Sch, Dept Construct Technol, TR-35230 Izmir, Turkey
[4] Osmaniye Korkut Ata Univ, Civil Engn Dept, TR-80010 Merkez, Osmaniye, Turkey
[5] Linnaeus Univ, Dept Bldg Technol, Hus M, S-3048 Vaxjo, Sweden
关键词
Historical masonry structures; Ambient vibration testing; System identification; Model calibration; Finite element model updating; OPERATIONAL MODAL-ANALYSIS; DAMAGE ASSESSMENT; IDENTIFICATION; COMBINATION; CALIBRATION; BUILDINGS;
D O I
10.1007/s13349-022-00610-3
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Growing interest in the preservation of architectural heritage has revealed a need for tools that are capable to reliably analyze masonry structures. For decades, finite element modeling approach has been commonly used in engineering society to simulate these structures under different conditions; but most of the time, the responses obtained from experiments differ from those of simulations due to the complexity in inherent physical aspects such as material properties, boundary conditions, mass and/or stiffness uncertainties. From this perspective, model updating techniques have the potential to overcome these inaccuracies and become essential tools in developing verified finite element models compatible with experiments. In this paper, sensitivity-based finite element model updating studies of the courtyard walls of the historical Isabey Mosque located in Selcuk/Izmir are presented. Dynamic characteristics of the structure are estimated from two sets of ambient vibration measurements by the EFDD operational modal analysis technique. The initial numerical model of the courtyard walls is constituted by macro modeling strategy. In order to obtain a much better correlation with in situ tests, the uncertain parameters such as mass density, Young's modulus, and boundary conditions of the initial numerical model are updated. Thus, a reliable finite element model that is more representative than the initial one is obtained to be used in future numerical assessment studies. In the presented paper, it is highlighted that the boundary conditions are often the most uncertain parts of a structural system, so they should be included in the updating process for realistic updating results.
引用
收藏
页码:1157 / 1172
页数:16
相关论文
共 40 条
[1]  
Allemang RJ, 2003, SOUND VIB, V37, P14
[2]  
[Anonymous], 2004, Mater Struct, V37, P497, DOI [10.1617/14120, DOI 10.1617/14120]
[3]  
[Anonymous], 2016, ARTEMIS EXTR PRO
[4]  
[Anonymous], 2017, Abaqus
[5]  
[Anonymous], 2017, MATLAB
[6]  
ASTM International, 2004, C119704 ASTM
[7]   Finite element model correlation and calibration of historic masonry monuments: review [J].
Atamturktur, Sezer ;
Laman, Jeffrey A. .
STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2012, 21 (02) :96-113
[8]   Learning from Construction Failures due to the 2009 L'Aquila, Italy, Earthquake [J].
Augenti, N. ;
Parisi, F. .
JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2010, 24 (06) :536-555
[9]   In situ static and dynamic investigations on the "Torre Grossa" masonry tower [J].
Bartoli, Gianni ;
Betti, Michele ;
Giordano, Saverio .
ENGINEERING STRUCTURES, 2013, 52 :718-733
[10]   Ambient vibration-based finite element model updating of an earthquake-damaged masonry tower [J].
Bassoli, Elisa ;
Vincenzi, Loris ;
D'Altri, Antonio Maria ;
de Miranda, Stefano ;
Forghieri, Marianna ;
Castellazzi, Giovanni .
STRUCTURAL CONTROL & HEALTH MONITORING, 2018, 25 (05)