A Robust LESO-based DC-Link Voltage Controller for Variable Speed Hydro-Electric Plants

被引:8
作者
Guo, Baoling [1 ,3 ]
Bacha, Seddik [1 ,3 ]
Alamir, Mazen [2 ,3 ]
Iman-Eini, Hossein [4 ]
机构
[1] Univ Grenoble Alpes, CNRS, Grenoble INP, G2elab, F-38000 Grenoble, France
[2] Univ Grenoble Alpes, CNRS, Grenoble INP, GIPSA Lab, F-38400 St Martin Dheres, France
[3] Univ Grenoble Alpes, Inst Engn, Grenoble, France
[4] Univ Tehran, Coll Engn, Sch Elect & Comp Engn, Tehran 1417466191, Iran
来源
2019 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT) | 2019年
关键词
Hydro-electric plants; DC-link; LESO; robust-ness; disturbance rejection; bandwidth;
D O I
10.1109/ICIT.2019.8754987
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Variable speed technique can improve the hydraulic power profitability and optimise the hydraulic transient process. Permanent magnet synchronous generator equipped with power electronics are widely implemented in the hydraulic context. The robust and efficient control of the DC-link voltage is important in the energy conversion process. However, the DC-link control stability is negatively affected in the presence of hydraulic power variations and various disturbances. In this paper, a Linear Extended State Observer (LESO)-based DC-link voltage controller is implemented in a variable speed hydro-electric plant. Comparative experiments with well-tuned PI controllers are conducted, the results prove its higher robustness and disturbance rejection ability under varying hydraulic conditions.
引用
收藏
页码:361 / 366
页数:6
相关论文
共 20 条
[1]  
Belhadji L., 2011, IECON 2011-37th Annual Conference on IEEE Industrial Electronics Society, P896
[2]   Adaptive MPPT Applied to Variable-Speed Microhydropower Plant [J].
Belhadji, Lakhdar ;
Bacha, Seddik ;
Munteanu, Iulian ;
Rumeau, Axel ;
Roye, Daniel .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2013, 28 (01) :34-43
[3]   Maximum Efficiency Point Tracking (MEPT) for Variable Speed Small Hydropower Plant With Neural Network Based Estimation of Turbine Discharge [J].
Borkowski, Dariusz .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2017, 32 (03) :1090-1098
[4]  
Gao ZQ, 2003, P AMER CONTR CONF, P4989
[5]  
Gaztanaga H, 2006, IEEE IND ELEC, P2813
[6]   Variable speed micro-hydro power plant: modelling, losses analysis, and experiment validation [J].
Guo, Baoling ;
Mohamed, Amgad ;
Bacha, Seddik ;
Alamir, Mazen .
2018 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2018, :1079-1084
[7]  
Guo BL, 2017, IEEE IND ELEC, P1783, DOI 10.1109/IECON.2017.8216302
[8]  
Guo BL, 2017, IEEE IND ELEC, P1747, DOI 10.1109/IECON.2017.8216296
[9]   From PID to Active Disturbance Rejection Control [J].
Han, Jingqing .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (03) :900-906
[10]   Fault Tolerant Control of DC-Link Voltage Sensor for Three-Phase AC/DC/AC PWM Converters [J].
Kim, Soo-Cheol ;
Thanh Hai Nguyen ;
Lee, Dong-Choon ;
Lee, Kyo-Beum ;
Kim, Jang-Mok .
JOURNAL OF POWER ELECTRONICS, 2014, 14 (04) :695-703