Baseline heart rate-adjusted electrocardiographic triggering for coronary artery electron-beam CT angiography

被引:4
|
作者
Lu, B
Zhuang, N
Mao, SS
Child, J
Carson, S
Budoff, MJ
机构
[1] Peking Union Med Coll, Dept Radiol, Cardiovasc Inst, Beijing 100037, Peoples R China
[2] Peking Union Med Coll, FuWaiu Hosp, Beijing 100037, Peoples R China
[3] Chinese Acad Med Sci, Beijing 100037, Peoples R China
[4] Univ Calif Los Angeles, Harbor Med Ctr, Dept Med, Div Cardiol, Torrance, CA 90509 USA
[5] St Johns Cardiovasc Res Ctr, Torrance, CA 90509 USA
关键词
computed tomography (CT); angiography; electron beam; image quality; coronary vessels; stenosis or obstruction;
D O I
10.1148/radiol.2332030953
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Conventional electrocardiographic (ECG) triggering (group 1, 53 patients) was compared with baseline heart rate-adjusted ECG triggering (group 2, 54 patients) for coronary artery electron-beam computed tomographic (CT) angiography. CT angiographic data sets were compared blindly with conventional angiograms according to segment. Nonassessability of coronary artery segments was reduced from 35% in group 1 to 13% in group 2 (P <.001). More motionfree coronary artery images were obtained in group 2 than in group 1, especially in the right coronary artery (95% vs 67%, P <.001). Overall sensitivity and specificity for luminal stenosis ( greater than or equal to 50%) were 69% and 82% (group 1) and 76% and 92% (group 2) (P >.05 and P <.001, respectively). Baseline heart rate-adjusted ECG triggering improves image quality at coronary artery CT angiography for detection of coronary artery disease. (C) RSNA, 2004.
引用
收藏
页码:590 / 595
页数:6
相关论文
共 50 条
  • [31] Diagnostic accuracy of dual-source CT coronary angiography with prospective ECG-triggering on different heart rate patients
    Sun, Ming-li
    Lu, Bin
    Wu, Run-ze
    Johnson, Laura
    Han, Lei
    Liu, Gang
    Yu, Fang-Fang
    Hou, Zhi-hui
    Gao, Yang
    Wang, Hong-yu
    Jiang, Shiliang
    Yang, Yue-jin
    Qiao, Shu-bin
    EUROPEAN RADIOLOGY, 2011, 21 (08) : 1635 - 1642
  • [32] Improved image quality at 256-slice coronary CT angiography in patients with a high heart rate and coronary artery disease: comparison with 64-slice CT imaging
    Oda, Seitaro
    Katahira, Kazuhiro
    Utsunomiya, Daisuke
    Takaoka, Hiroko
    Honda, Keiichi
    Noda, Katsuo
    Oshima, Shuichi
    Yuki, Hideaki
    Namimoto, Tomohiro
    Yamashita, Yasuyuki
    ACTA RADIOLOGICA, 2015, 56 (11) : 1308 - 1314
  • [33] Dual energy for material differentiation in coronary arteries using electron-beam CT
    Sengupta, S
    Jha, S
    Walter, D
    Du, YF
    Tkaczyk, EJ
    Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 1306 - 1316
  • [34] Effect of Heart Rate and Coronary Calcification on the Diagnostic Accuracy of the Dual-Source CT Coronary Angiography in Patients with Suspected Coronary Artery Disease
    Meng, Lingdong
    Cui, Lianqun
    Cheng, Yuntao
    Wu, Xiaoyan
    Tang, Yuansheng
    Wang, Yong
    Xu, Fayun
    KOREAN JOURNAL OF RADIOLOGY, 2009, 10 (04) : 347 - 354
  • [35] Coronary microvascular functional reserve:: Quantification of long-term changes with electron-beam CT -: Preliminary results in a porcine model
    Möhlenkamp, S
    Behrenbeck, TR
    Lerman, A
    Lerman, LO
    Pankratz, VS
    Sheedy, PF
    Weaver, AL
    Ritman, EL
    RADIOLOGY, 2001, 221 (01) : 229 - 236
  • [36] MRI OF THE CORONARY-ARTERIES - POSSIBILITIES AND LIMITATIONS - A COMPARISON WITH CORONARY ANGIOGRAPHY, ECHO CARDIOGRAPHY, AND ELECTRON-BEAM TOMOGRAPHY
    STEHLING, MK
    VONSMEKAL, A
    REISER, M
    RADIOLOGE, 1994, 34 (08): : 462 - 468
  • [37] Dual-source CT coronary angiography: Image quality, mean heart rate, and heart rate variability
    Matt, David
    Scheffel, Hans
    Leschka, Sebastian
    Flohr, Thomas G.
    Marincek, Borut
    Kaufmann, Philipp A.
    Alkadhi, Hatem
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (03) : 567 - 573
  • [38] Dual-source CT coronary angiography without heart rate or rhythm control in comparison with conventional coronary angiography
    Xiang Ming Fang
    Hong Wei Chen
    Xiao Yun Hu
    Jian Bao
    Yin Chen
    Zhen Yu Yang
    Orla Buckley
    Xiao Qing Wu
    The International Journal of Cardiovascular Imaging, 2010, 26 : 323 - 331
  • [39] DETECTION OF HEART CALCIFICATION WITH ELECTRON-BEAM CT - INTEROBSERVER AND INTRAOBSERVER RELIABILITY FOR SCORING QUANTIFICATION
    KAUFMANN, RB
    SHEEDY, PF
    BREEN, JF
    KELZENBERG, JR
    KRUGER, BL
    SCHWARTZ, RS
    MOLL, PP
    RADIOLOGY, 1994, 190 (02) : 347 - 352
  • [40] Step and shoot coronary CT angiography using 256-slice CT: effect of heart rate and heart rate variability on image quality
    Muenzel, D.
    Noel, P. B.
    Dorn, F.
    Dobritz, M.
    Rummeny, E. J.
    Huber, A.
    EUROPEAN RADIOLOGY, 2011, 21 (11) : 2277 - 2284