摘要
There is an increasing trend to have data rapidly ready at the patient's bedside. The general principle behind point-of-care (POC) testing is that "faster is better" (from vein to brain'). The entire process for laboratory testing includes withdrawal of blood into special (pre-labelled) tubes, transportation of the sample to the central laboratory where the plasma is separated from the blood cells by centrifugation, carefully pippeting of a defined volume of plasma that is placed in the analyzer. POC instruments provide us with the potential to do old things in new ways. With the help of portable POC analyzers a variety of laboratory parameters including coagulation parameters, blood gas analysis, electrolytes, markers of organ function can be measured next to the patient's bed thus significantly shorting turnaround-time (TAT). Cost analyses of new monitoring devices are necessary in today's climate of cost savings. It is important to capture all costs and not only costs of the test kits. Direct costs (e.g. test cartridges, costs for the analyzers, cost for quality control) may constitute only a small percentage of the true costs. Hidden costs consist of overhead costs (e.g. transportation) and the consequences of delayed results. The present overview summarizes the available POC systems in Germany and may serve as a decision maker for those who are interested in introducing POC monitoring systems.
引用
收藏
页码:158 / 164
页数:7
相关论文
共 35 条
  • [1] BEDSIDE COAGULATION MONITORING
    AMMAR, T
    REICH, DL
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1995, 9 (04) : 353 - 354
  • [2] MEASUREMENT OF THE ACTIVATED PARTIAL THROMBOPLASTIN TIME FROM A CAPILLARY (FINGERSTICK) SAMPLE OF WHOLE-BLOOD - A NEW METHOD FOR MONITORING HEPARIN-THERAPY
    ANSELL, J
    TIARKS, C
    HIRSH, J
    MCGEHEE, W
    ADLER, D
    WEIBERT, R
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1991, 95 (02) : 222 - 227
  • [3] BLOOD LACTATE LEVELS ARE SUPERIOR TO OXYGEN-DERIVED VARIABLES IN PREDICTING OUTCOME IN HUMAN SEPTIC SHOCK
    BAKKER, J
    COFFERNILS, M
    LEON, M
    GRIS, P
    VINCENT, JL
    [J]. CHEST, 1991, 99 (04) : 956 - 962
  • [4] BEDSIDE COAGULATION MONITORING IN HEPARIN-TREATED PATIENTS WITH ACTIVE THROMBOEMBOLIC DISEASE - A CORONARY-CARE UNIT EXPERIENCE
    BECKER, RC
    CYR, J
    CORRAO, JM
    BALL, SP
    [J]. AMERICAN HEART JOURNAL, 1994, 128 (04) : 719 - 723
  • [5] RETRACTED: Point-of-care (POC) measurement of coagulation after cardiac surgery (Retracted Article)
    Boldt, J
    Walz, G
    Triem, J
    Suttner, S
    Kumle, B
    [J]. INTENSIVE CARE MEDICINE, 1998, 24 (11) : 1187 - 1193
  • [6] RETRACTED: Point-of-care (POC) testing of lactate in the intensive care patient - Accuracy, reliability, and costs of different measurement systems (Retracted article. See vol. 55, pg. 903, 2011)
    Boldt, J
    Kumle, B
    Suttner, S
    Haisch, G
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2001, 45 (02) : 194 - 199
  • [7] CASTRO JH, 1995, AM J CLIN PATHOL S1, V104, pS95
  • [8] CHERNOW B, 1991, CRIT CARE MED, V19, P313
  • [9] DECRESCE RP, 1995, ARCH PATHOL LAB MED, V119, P898
  • [10] DESPOTIS G, 1995, ANESTHESIOLOGY, V80, P338