Application of chloromethylated polystyrene functionalized with N,N-bis(naphthylideneimino)diethylenetriamine in an on-line preconcentration system for the determination of cadmium by FAAS

被引:40
作者
Chamjangali, M. Arab [1 ]
Farooji, S. Talebzadeh [1 ]
Bahramian, B. [1 ]
机构
[1] Shahrood Univ Technol, Coll Chem, Shahrood, Iran
关键词
Atomic absorption spectrometry; On-line preconcentration; Polystyrene; Cadmium(II); ATOMIC-ABSORPTION-SPECTROMETRY; SOLID-PHASE EXTRACTION; KNOTTED REACTOR; ENVIRONMENTAL-SAMPLES; SORBENT EXTRACTION; COMPLEXING AGENT; HEAVY-METALS; OPTIMIZATION; LEAD; CD;
D O I
10.1016/j.jhazmat.2009.09.130
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A simple and sensitive on-line preconcentration procedure was developed for the determination of trace levels of cadmium(II) by flame atomic absorption spectrometry. A mini-column packed with a chloromethylated polystyrene functionalized with N,N-bis(naphthylideneimino)diethylenetriamine (NAPdein) was used for the on-line enrichment of cadmium(II) at pH 7.0. All chemical and flow injection variables were optimized for the quantitative preconcentration and determination of cadmium(II). Under the optimum conditions, the calibration graph obtained was linear over the concentration rang of 1.00-30.0 mu g L-1. The detection limit (DL) and enrichment factor were 0.25 mu g L-1 and 50-fold, respectively. The relative standard deviations for 7 replicate determinations of cadmium(II) at the 2.0 and 20 mu g L-1 levels were 5.1% and 2.2%, respectively. The effect of the presence of various species commonly associated with real samples was also investigated. The accuracy of the proposed method was demonstrated by analyzing different water samples. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:843 / 850
页数:8
相关论文
共 33 条
[1]   1,10-phenanthroline as a complexing agent for on-line sorbent extraction preconcentration for flow injection-flame atomic absorption spectrometry [J].
Ali, A ;
Yin, XF ;
Shen, H ;
Ye, YX ;
Gu, X .
ANALYTICA CHIMICA ACTA, 1999, 392 (2-3) :283-289
[2]  
ALI A, 2007, J HAZARD MATER, V148, P319
[4]  
Benabdallah T, 2004, S AFR J CHEM-S-AFR T, V57, P33
[5]   Development of a flow system for the determination of cadmium in fuel alcohol using vermicompost as biosorbent and flame atomic absorption spectrometry [J].
Bianchin, Joyce Nunes ;
Martendal, Edmar ;
Mior, Renata ;
Alves, Vanessa Nunes ;
Tavares Araujo, Cleide Sandra ;
Melo Coelho, Nivia Maria ;
Carasek, Eduardo .
TALANTA, 2009, 78 (02) :333-336
[6]   Determination of cadmium by flame-atomic absorption Spectrometry after preconcentration on silica gel modified with cupferron [J].
Bortoleto, GG ;
Macarovscha, GT ;
Cadore, S .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2004, 15 (02) :313-317
[7]  
Bruhn CG, 1999, BOL SOC CHIL QUIM, V44, P321
[8]   Solid phase extraction of trace elements [J].
Camel, V .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (07) :1177-1233
[9]   Optimization of the preconcentration system of cadmium with 1(2-thiazolylazo)-p-cresol using a knotted reactor and flame atomic absorption spectrometric detection [J].
Cerutti, S ;
Ferreira, SLC ;
Gásquez, JA ;
Olsina, RA ;
Martinez, LD .
JOURNAL OF HAZARDOUS MATERIALS, 2004, 112 (03) :279-283
[10]   ELECTROCHEMICAL STUDIES OF MANGANESE(II) COMPLEXES CONTAINING PENTADENTATE LIGANDS WITH O2N3, O3N2, AND O2SN2 DONOR SETS [J].
COLEMAN, WM ;
BOGGESS, RK ;
HUGHES, JW ;
TAYLOR, LT .
INORGANIC CHEMISTRY, 1981, 20 (03) :700-706