Evaluation of the motion of lung tumors during stereotactic body radiation therapy (SBRT) with four-dimensional computed tomography (4DCT) using real-time tumor-tracking radiotherapy system (RTRT)

被引:51
作者
Harada, Keiichi [1 ]
Katoh, Norio [2 ,3 ]
Suzuki, Ryusuke [2 ]
Ito, Yoichi M. [4 ]
Shimizu, Shinichi [3 ,5 ]
Onimaru, Rikiya [1 ]
Inoue, Tetsuya [2 ]
Miyamoto, Naoki [2 ]
Shirato, Hiroki [1 ,3 ]
机构
[1] Hokkaido Univ, Grad Sch Med, Dept Radiat Med, Kita Ku, North 15 West 7, Sapporo, Hokkaido 0608638, Japan
[2] Hokkaido Univ Hosp, Dept Radiat Oncol, Kita Ku, North 14 West 5, Sapporo, Hokkaido 0608638, Japan
[3] Hokkaido Univ, Grad Sch Med, Global Stn Med Sci & Engn, Global Inst Collaborat Res & Educ,Kita Ku, North 15 West 7, Sapporo, Hokkaido 0608638, Japan
[4] Hokkaido Univ, Grad Sch Med, Dept Biostat, Kita Ku, North 15 West 7, Sapporo, Hokkaido 0608638, Japan
[5] Hokkaido Univ, Grad Sch Med, Dept Radiat Oncol, Kita Ku, North 15 West 7, Sapporo, Hokkaido 0608638, Japan
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2016年 / 32卷 / 02期
关键词
Four-dimensional computed tomography; Stereotactic body radiation therapy; Real-time tumor-tracking radiotherapy; Organ motion; IMAGE-GUIDED RADIOTHERAPY; INTERNAL TARGET VOLUME; GATED RADIOTHERAPY; CANCER;
D O I
10.1016/j.ejmp.2015.10.093
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We investigated the usefulness of four-dimensional computed tomography (4DCT) performed before stereotactic body radiation therapy (SBRT) in determining the internal margins for peripheral lung tumors. Methods and Materials: The amplitude of the movement of a fiducial marker near a lung tumor measured using the maximum intensity projection (MIP) method in 4DCT imaging was acquired before the SBRT (Amp(CT)) and compared with the mean amplitude of the marker movement during SBRT (Amp(mean)) and with the maximum amplitude of the marker movement during SBRT (Amp(max)) using a real-time tumortracking radiotherapy (RTRT) system with 22 patients. Results: There were no significant differences between the means of the Amp(mean) and the means of the Amp(CT) in all directions (LR, P = 0.45; CC, P = 0.80; AP, P = 0.65). The means of the Amp(max) were significantly larger than the means of the Amp(CT) in all directions (LR, P < 0.01; CC, P = 0.03; AP, P < 0.01). In the lower lobe, the mean difference of the Amp(CT) from the mean of the Amp(max) was 5.7 +/- 8.0 mm, 12.5 +/- 16.7 mm, and 6.8 +/- 8.5 mm in the LR, CC, and AP directions, respectively. Conclusions: Acquiring 4DCT MIP images before the SBRT treatment is useful to establish the mean amplitude for a patient during SBRT but it underestimates the maximum amplitude during actual SBRT. Caution must be paid to determine the margin with the 4DCT especially for tumors at the lower lobe where it is of the potentially greatest benefit. (C) 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd.
引用
收藏
页码:305 / 311
页数:7
相关论文
共 29 条
  • [1] Irregular breathing during 4DCT scanning of lung cancer patients: Is the midventilation approach robust?
    Aznar, Marianne C.
    Persson, Gitte F.
    Kofoed, Inger M.
    Nygaard, Ditte E.
    Korreman, Stine S.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (01): : 69 - 75
  • [2] Residual motion of lung tumors in end-of-inhale respiratory gated radiotherapy based on external surrogates
    Berbeco, Ross I.
    Nishioka, Seiko
    Shirato, Hiroki
    Jiang, Steve B.
    [J]. MEDICAL PHYSICS, 2006, 33 (11) : 4149 - 4156
  • [3] Is abdominal compression useful in lung stereotactic body radiation therapy? A 4DCT and dosimetric lobe-dependent study
    Bouilhol, Gauthier
    Ayadi, Myriam
    Rit, Simon
    Thengumpallil, Sheeba
    Schaerer, Joel
    Vandemeulebroucke, Jef
    Claude, Line
    Sarrut, David
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2013, 29 (04): : 333 - 340
  • [4] Estimation of error in maximal intensity projection-based internal target volume of lung tumors: A simulation and comparison study using dynamic magnetic resonance imaging
    Cai, Jing
    Read, Paul W.
    Baisden, Joseph M.
    Larner, James M.
    Benedict, Stanley H.
    Sheng, Ke
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : 895 - 902
  • [5] Determination of patient-specific internal gross tumor volumes for lung cancer using four-dimensional computed tomography
    Ezhil, Muthuveni
    Vedam, Sastry
    Balter, Peter
    Choi, Bum
    Mirkovic, Dragan
    Starkschall, George
    Chang, Joe Y.
    [J]. RADIATION ONCOLOGY, 2009, 4
  • [6] CLINICAL ACCURACY OF THE RESPIRATORY TUMOR TRACKING SYSTEM OF THE CYBERKNIFE: ASSESSMENT BY ANALYSIS OF LOG FILES
    Hoogeman, Mischa
    Prevost, Jean-Briac
    Nuyttens, Joost
    Poell, Johan
    Levendag, Peter
    Heijmen, Ben
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (01): : 297 - 303
  • [7] Imura M, 2008, INT J RADIAT ONCOL, V70, P382
  • [8] Imura M, 2005, INT J RADIAT ONCOL, V63, P1442
  • [9] Stereotactic body radiotherapy using gated radiotherapy with real-time tumor-tracking for stage I non-small cell lung cancer
    Inoue, Tetsuya
    Katoh, Norio
    Onimaru, Rikiya
    Shimizu, Shinichi
    Tsuchiya, Kazuhiko
    Suzuki, Ryusuke
    Sakakibara-Konishi, Jun
    Shinagawa, Naofumi
    Oizumi, Satoshi
    Shirato, Hiroki
    [J]. RADIATION ONCOLOGY, 2013, 8
  • [10] The impact of respiratory gating on lung dosimetry in stereotactic body radiotherapy for lung cancer
    Jang, Seong Soon
    Huh, Gil Ja
    Park, Suk Young
    Yang, Po Song
    Cho, Eun Youn
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (06): : 682 - 689