Automatic Cardiac Self-Gating of Small-Animal PET Data

被引:4
作者
Herraiz, Joaquin L. [1 ,2 ]
Herranz, Elena [3 ,4 ]
Cal-Gonzalez, Jacobo [5 ]
Vaquero, Juan J. [6 ,7 ]
Desco, Manuel [6 ,7 ,8 ]
Cusso, Lorena [6 ,7 ,8 ]
Udias, Jose M. [2 ]
机构
[1] MIT, Madrid MIT M Vis Consortium, 77 Massachusetts Ave, Cambridge, MA 02139 USA
[2] Univ Complutense Madrid, CEI Moncloa, Grp Fis Nucl, Madrid, Spain
[3] Massachusetts Gen Hosp, AA Martinos Ctr Biomed Imaging, Charlestown, MA USA
[4] Harvard Univ, Sch Med, Boston, MA 02115 USA
[5] Med Univ Vienna, Ctr Med Phys & Biomed Engn, Vienna, Austria
[6] Univ Carlos III Madrid, Dept Ingn Biomed & Ingn Aerosp, Leganes, Spain
[7] Inst Invest Sanitaria Gregorio Maranon, Madrid, Spain
[8] Ctr Invest Biomed Red Salud Mental CIBERSAM, Barcelona, Spain
关键词
List-mode; PET; Small animal; Cardiac gating; Self-gating; GATED PET; RECONSTRUCTION; TOMOGRAPHY; SOFTWARE; SCANNER; 1ST;
D O I
10.1007/s11307-015-0868-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The cardiac gating signal (CGS) in positron emission tomography (PET) studies is usually obtained from an electrocardiography (ECG) monitor. In this work, we propose a method to obtain the CGS in small-animal PET using the acquired list-mode data without using any hardware or end-user input. Procedures: The CGS was obtained from the number of coincidences over time acquired in the lines-of-response connected with the cardiac region. This region is identified in the image as its value changes with frequencies in the range of 3 to 12 Hz. The procedure was tested in a study with 29 Wistar rats and 6 mice injected with 2-deoxy-2-[F-18]fluoro-D-glucose, which underwent a 45-min single-bed list-mode PET scan of the heart syncronized with an ECG. The estimated signals and the reconstructed images using eight-gated frames were compared with the ones obtained using the ECG signal from the monitor. Results: The differences of the PET-based CGS with respect to the ECG relative to the duration of the heartbeats were 5.6 % in rats and 11.0 % in mice. The reconstructed gated images obtained from the proposed method do not differ qualitatively with respect to the ones obtained with the ECG. The quantitative analysis of both set of images were performed measuring the volume of the left ventricle (LV) of the rats in the end-of-systole and end-of-diastole phase. The differences found in these parameters between both methods were below 12.1 % in the ESV and 9.3 % in the EDV with a 95 % confidence interval, which are comparable to the accuracy (7 %) of the method used for segmenting the LV. Conclusion: The proposed method is able to provide a valid and accurate CGS in small-animal PET list-mode data.
引用
收藏
页码:109 / 116
页数:8
相关论文
共 20 条
[11]   FIRST:: Fast Iterative Reconstruction Software for (PET) tomography [J].
Herraiz, J. L. ;
Espana, S. ;
Vaquero, J. J. ;
Desco, M. ;
Udias, J. M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (18) :4547-4565
[12]   Fully 3D GPU PET reconstruction [J].
Herraiz, J. L. ;
Espana, S. ;
Cal-Gonzalez, J. ;
Vaquero, J. J. ;
Desco, M. ;
Udias, J. M. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 :S169-S171
[13]   LOR-OSEM: statistical PET reconstruction from raw line-of-response histograms [J].
Kadrmas, DJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (20) :4731-4744
[14]   A new fast and fully automated software based algorithm for extracting respiratory signal from raw PET data and its comparison to other methods [J].
Kesner, Adam Leon ;
Kuntner, Claudia .
MEDICAL PHYSICS, 2010, 37 (10) :5550-5559
[15]   Respiratory Gated PET Derived in a Fully Automated Manner From Raw PET Data [J].
Kesner, Adam Leon ;
Bundschuh, Ralph Alexander ;
Detorie, Nicole Christine ;
Dahlbom, Magnus ;
Ziegler, Sibylle Ilsa ;
Czernin, Johannes ;
Silverman, Daniel Hillel .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) :677-686
[16]   4D-PET data sorting into different number of phases: a NEMA IQ phantom study [J].
Mancosu, Pietro ;
Sghedoni, Roberto ;
Bettinardi, Valentino ;
Fioroni, Federica ;
Aquilina, Mark A. ;
Grassi, Elisa ;
Fazio, Ferruccio ;
Borasi, Giovanni ;
Gilardi, Maria C. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2009, 10 (04) :220-231
[17]   FAST CALCULATION OF THE EXACT RADIOLOGICAL PATH FOR A 3-DIMENSIONAL CT ARRAY [J].
SIDDON, RL .
MEDICAL PHYSICS, 1985, 12 (02) :252-255
[18]  
Wang YC, 2006, J NUCL MED, V47, P1891
[19]   Positron emission tomography imaging of cardiac reporter gene expression in living rats [J].
Wu, JC ;
Inubushi, M ;
Sundaresan, G ;
Schelbert, HR ;
Gambhir, SS .
CIRCULATION, 2002, 106 (02) :180-183
[20]   Cardiac PET imaging in mice with simultaneous cardiac and respiratory gating [J].
Yang, YF ;
Rendig, S ;
Siegel, S ;
Newport, DF ;
Cherry, SR .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (13) :2979-2989