Automatic Cardiac Self-Gating of Small-Animal PET Data

被引:4
作者
Herraiz, Joaquin L. [1 ,2 ]
Herranz, Elena [3 ,4 ]
Cal-Gonzalez, Jacobo [5 ]
Vaquero, Juan J. [6 ,7 ]
Desco, Manuel [6 ,7 ,8 ]
Cusso, Lorena [6 ,7 ,8 ]
Udias, Jose M. [2 ]
机构
[1] MIT, Madrid MIT M Vis Consortium, 77 Massachusetts Ave, Cambridge, MA 02139 USA
[2] Univ Complutense Madrid, CEI Moncloa, Grp Fis Nucl, Madrid, Spain
[3] Massachusetts Gen Hosp, AA Martinos Ctr Biomed Imaging, Charlestown, MA USA
[4] Harvard Univ, Sch Med, Boston, MA 02115 USA
[5] Med Univ Vienna, Ctr Med Phys & Biomed Engn, Vienna, Austria
[6] Univ Carlos III Madrid, Dept Ingn Biomed & Ingn Aerosp, Leganes, Spain
[7] Inst Invest Sanitaria Gregorio Maranon, Madrid, Spain
[8] Ctr Invest Biomed Red Salud Mental CIBERSAM, Barcelona, Spain
关键词
List-mode; PET; Small animal; Cardiac gating; Self-gating; GATED PET; RECONSTRUCTION; TOMOGRAPHY; SOFTWARE; SCANNER; 1ST;
D O I
10.1007/s11307-015-0868-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The cardiac gating signal (CGS) in positron emission tomography (PET) studies is usually obtained from an electrocardiography (ECG) monitor. In this work, we propose a method to obtain the CGS in small-animal PET using the acquired list-mode data without using any hardware or end-user input. Procedures: The CGS was obtained from the number of coincidences over time acquired in the lines-of-response connected with the cardiac region. This region is identified in the image as its value changes with frequencies in the range of 3 to 12 Hz. The procedure was tested in a study with 29 Wistar rats and 6 mice injected with 2-deoxy-2-[F-18]fluoro-D-glucose, which underwent a 45-min single-bed list-mode PET scan of the heart syncronized with an ECG. The estimated signals and the reconstructed images using eight-gated frames were compared with the ones obtained using the ECG signal from the monitor. Results: The differences of the PET-based CGS with respect to the ECG relative to the duration of the heartbeats were 5.6 % in rats and 11.0 % in mice. The reconstructed gated images obtained from the proposed method do not differ qualitatively with respect to the ones obtained with the ECG. The quantitative analysis of both set of images were performed measuring the volume of the left ventricle (LV) of the rats in the end-of-systole and end-of-diastole phase. The differences found in these parameters between both methods were below 12.1 % in the ESV and 9.3 % in the EDV with a 95 % confidence interval, which are comparable to the accuracy (7 %) of the method used for segmenting the LV. Conclusion: The proposed method is able to provide a valid and accurate CGS in small-animal PET list-mode data.
引用
收藏
页码:109 / 116
页数:8
相关论文
共 20 条
[1]  
[Anonymous], 2007, CARDIAC PET PETCT IM, DOI DOI 10.1007/978-0-387-38295-1_2
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Erroneous cardiac ECG-gated PET list-mode trigger events can be retrospectively identified and replaced by an offline reprocessing approach: first results in rodents [J].
Boening, Guido ;
Todica, Andrei ;
Vai, Alessandro ;
Lehner, Sebastian ;
Xiong, Guoming ;
Mille, Erik ;
Ilhan, Harun ;
la Fougere, Christian ;
Bartenstein, Peter ;
Hacker, Marcus .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (22) :7937-7959
[4]   List Mode-Driven Cardiac and Respiratory Gating in PET [J].
Buether, Florian ;
Dawood, Mohammad ;
Stegger, Lars ;
Wuebbeling, Frank ;
Schaefers, Michael ;
Schober, Otmar ;
Schaefers, Klaus P. .
JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (05) :674-681
[5]  
Croteau E, 2003, J NUCL MED, V44, P1655
[6]  
Cusso L, 2013, WORLD MOL IMAG CONG, P79
[7]  
Cusso L, 2009, ABSTRACT EUR SOC MOL, P104
[8]  
Dineley J, 2010, FULLY AUTOMATED GATI
[9]   A Novel Method for Respiratory Motion Gated With Geometric Sensitivity of the Scanner in 3D PET [J].
He, Jianfeng ;
O'Keefe, Graeme J. ;
Gong, Sylvia Jie ;
Jones, Gareth ;
Saunder, Tim ;
Scott, Andrew M. ;
Geso, Moshi .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (05) :2557-2565
[10]   Design and validation of Segment - freely available software for cardiovascular image analysis [J].
Heiberg E. ;
Sjögren J. ;
Ugander M. ;
Carlsson M. ;
Engblom H. ;
Arheden H. .
BMC Medical Imaging, 10 (1)