Digital breast tomosynthesis (3D-mammography) screening: A pictorial review of screen-detected cancers and false recalls attributed to tomosynthesis in prospective screening trials

被引:21
作者
Houssami, Nehmat [1 ]
Lang, Kristina [2 ]
Bernardi, Daniela [3 ]
Tagliafico, Alberto [4 ]
Zackrisson, Sophia [2 ]
Skaane, Per [5 ]
机构
[1] Univ Sydney, Sydney Med Sch, Sch Publ Hlth A27, Screening & Test Evaluat Program, Sydney, NSW 2006, Australia
[2] Lund Univ, Translat Med Malmo, Dept Med Radiol, Lund, Sweden
[3] Azienda Prov Serv Sanitari, Osped Trento, Dept Diagnost, UO Senol Clin & Screening Mammog, Trento, Italy
[4] Univ Genoa, Inst Anat, Dept Expt Med, Largo Rosanna Benzi 8, I-16132 Genoa, Italy
[5] Univ Oslo, Oslo Univ Hosp Ullevaal, Dept Radiol, N-0316 Oslo, Norway
关键词
Breast cancer detection; Cancer screening; Digital breast tomosynthesis; False-positive recall; Mammography; Population screening; POSITIVE DETECTION; MAMMOGRAPHY FFDM; 2D-MAMMOGRAPHY; IMPLEMENTATION; PERFORMANCE;
D O I
10.1016/j.breast.2016.01.007
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
This pictorial review highlights cancers detected only at tomosynthesis screening and screens falsely recalled in the course of breast tomosynthesis screening, illustrating both true-positive (TP) and false-positive (FP) detection attributed to tomosynthesis. Images and descriptive data were used to characterise cases of screen-detection with tomosynthesis, sourced from prospective screening trials that performed standard (2D) digital mammography (DM) and tomosynthesis (3D-mammography) in the same screening participants. Exemplar cases from four trials highlight common themes of relevance to screening practice including: the type of lesions frequently made more conspicuous or perceptible by tomosynthesis (spiculated masses, and architectural distortions); the histologic findings (both TP and FP) of tomosynthesis-only detection; and the need to extend breast work-up protocols (additional imaging including ultrasound and MRI, and tomosynthesis-guided biopsy) if tomosynthesis is adopted for primary screening. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:119 / 134
页数:16
相关论文
共 50 条
[41]   Effectiveness of hybrid digital breast tomosynthesis/digital mammography compared to digital mammography in women presenting for routine screening at Maroondah BreastScreen: Study protocol for a co-designed, non-randomised prospective trial [J].
Houssami, Nehmat ;
Lockie, Darren ;
Giles, Michelle ;
Doncovio, Sally ;
Marr, Georgina ;
Taylor, David ;
Li, Tong ;
Nickel, Brooke ;
Marinovich, M. Luke .
BREAST, 2024, 74
[42]   Comparison of interval breast cancers with 2D digital mammography versus 3D digital breast tomosynthesis in a large community-based practice [J].
Winter, Andrea M. ;
Kazmi, Sakina ;
Hardy, Anna K. ;
Bennett, Debbie L. .
BREAST JOURNAL, 2020, 26 (10) :1953-1959
[43]   Not all false positive diagnoses are equal: On the prognostic implications of false-positive diagnoses made in breast MRI versus in mammography / digital tomosynthesis screening [J].
Christiane K. Kuhl ;
Annika Keulers ;
Kevin Strobel ;
Hannah Schneider ;
Nadine Gaisa ;
Simone Schrading .
Breast Cancer Research, 20
[44]   Digital breast tomosynthesis (DBT) plus synthesised two-dimensional mammography (s2D) in breast cancer screening is associated with higher cancer detection and lower recalls compared to digital mammography (DM) alone: results of a systematic review and meta-analysis [J].
Heywang-Koebrunner, Sylvia H. ;
Jaensch, Alexander ;
Hacker, Astrid ;
Weinand, Sina ;
Vogelmann, Tobias .
EUROPEAN RADIOLOGY, 2022, 32 (04) :2301-2312
[45]   Traditional versus modern approaches to screening mammography: a comparison of computer-assisted detection for synthetic 2D mammography versus an artificial intelligence algorithm for digital breast tomosynthesis [J].
Bahl, Manisha ;
Kshirsagar, Ashwini ;
Pohlman, Scott ;
Lehman, Constance D. .
BREAST CANCER RESEARCH AND TREATMENT, 2025, 210 (03) :529-537
[46]   Strategies to Increase Cancer Detection: Review of True-Positive and False-Negative Results at Digital Breast Tomosynthesis Screening [J].
Korhonen, Katrina E. ;
Weinstein, Susan P. ;
McDonald, Elizabeth S. ;
Conant, Emily F. .
RADIOGRAPHICS, 2016, 36 (07) :1954-1965
[47]   THE CURRENT DETECTABILITY OF BREAST-CANCER IN A MAMMOGRAPHIC SCREENING-PROGRAM - A REVIEW OF THE PREVIOUS MAMMOGRAMS OF INTERVAL AND SCREEN-DETECTED CANCERS [J].
VANDIJCK, JAAM ;
VERBEEK, ALM ;
HENDRIKS, JHCL ;
HOLLAND, R .
CANCER, 1993, 72 (06) :1933-1938
[48]   Digital breast tomosynthesis (DBT) plus synthesised two-dimensional mammography (s2D) in breast cancer screening is associated with higher cancer detection and lower recalls compared to digital mammography (DM) alone: results of a systematic review and meta-analysis [J].
Sylvia H. Heywang-Köbrunner ;
Alexander Jänsch ;
Astrid Hacker ;
Sina Weinand ;
Tobias Vogelmann .
European Radiology, 2022, 32 :2301-2312
[49]   Breast cancer screening with tomosynthesis (3D mammography) with acquired or synthetic 2D mammography compared with 2D mammography alone (STORM-2): a population-based prospective study [J].
Bernardi, Daniela ;
Macaskill, Petra ;
Pellegrini, Marco ;
Valentini, Marvi ;
Fanto, Carmine ;
Ostillio, Livio ;
Tuttobene, Paolina ;
Luparia, Andrea ;
Houssami, Nehmat .
LANCET ONCOLOGY, 2016, 17 (08) :1105-1113
[50]   An analysis of screen-detected invasive cancers by grade in the English breast cancer screening programme: are we failing to detect sufficient small grade 3 cancers? [J].
Blanks, R. G. ;
Wallis, M. G. ;
Alison, R. J. ;
Given-Wilson, R. M. .
EUROPEAN RADIOLOGY, 2021, 31 (04) :2548-2558