Electrospray Ionization Mass Spectrometry for the Quantification of Inorganic Cations and Anions

被引:12
作者
Hotta, Hiroki [1 ]
Tsunoda, Kin-ichi [2 ]
机构
[1] Nara Univ Educ, Dept Chem, Nara 6308528, Japan
[2] Gunma Univ, Dept Chem & Chem Biol, Kiryu, Gunma 3768515, Japan
基金
日本学术振兴会;
关键词
Electrospray ionization mass spectrometry; quantification of inorganic ions; ternary complex; METAL-EDTA COMPLEXES; ION SUPPRESSION; ESI-MS; CYANIDE; CHROMATOGRAPHY; SENSITIVITY; EXTRACTION; HALIDES; PLANT; WATER;
D O I
10.2116/analsci.31.7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Recent studies from our laboratory on electrospray ionization mass spectrometry (ESI-MS) for the quantification of inorganic cations and anions are reviewed. Metal ions were determined by ESI-MS in negative-ion mode as monovalent negative ions of their aminopolycarboxylate (APC) complexes, where excess amounts of the APC agents were added to sample solutions. Among the APCs studied, we found trans-1,2-diaminocyclohexane-N,N,N',N'-tetraacetic acid (CyDTA, the chemical forms in a complex were expressed as H(n)cydta(n-4)) as the best chelating agent. A size exclusion column was used for on-line separation of the metal-APC complexes from matrix salts in samples. Total amounts of Al, Ni, Cu, Zn, and Pb in the biological certified reference materials (CRM), Olive Leaves (BCR-062) and Plankton (BCR-414), and in a soil CRM (JSAC-0401) were successfully determined by the proposed method. Halide ions (X- = F-, Cl-, Br- and I-) and cyanide (CN-) were determined by ESI-MS based on the formation of ternary complexes of metals, chelating agents and the analyte anions. Negative ions of the ternary complexes of group 13 elements, nitrilotriacetic acid (NTA, H(n)nta(n-3)), and halides, i.e., [AlF(nta)](-) for F-, and [InX(nta)](-) for other halides, were measured; the limits of detection (LODs) were 10 nmol dm(-3) for F-, 0.31 mu mol dm(-3) for Cl-, 3.8 nmol dm(-3) for Br-, and 1.6 nmol dm(-3) for I-, respectively. In the case of CN-, an LOD of 20 nmol dm(-3) was obtained based on measurements of the ternary complex of Cu-II, CN- and 4-(2-pyridylazo)resorcinol (PAR, H(n)par(n-2)), i.e., [63Cu(II)(CN)(par)](-) (m/z 302). Moreover, quantitative methods for Cr-VI and Cr-III by ESI-MS were developed, where HCrO4- (m/z 117) for Cr-VI and [Cr-III(cydta)](-) for Cr-III were used for measurements.
引用
收藏
页码:7 / 14
页数:8
相关论文
共 52 条
[51]   Amperometric determination of cyanides at the low ppb level by automated preconcentration based on gas diffusion coupled to sequential injection analysis [J].
Zacharis, Constantinos K. ;
Tzanavaras, Paraskevas D. ;
Voulgaropoulos, Anastasios N. ;
Karlberg, Bo .
TALANTA, 2009, 77 (05) :1620-1626
[52]   Cyanide distribution in human tissue, determined by GC/ECD/HS [J].
Zhang, CS ;
Zheng, H ;
Jin, OY ;
Feng, SZ ;
Taes, YEC .
ANALYTICAL LETTERS, 2005, 38 (02) :247-256