摘要
Recent studies from our laboratory on electrospray ionization mass spectrometry (ESI-MS) for the quantification of inorganic cations and anions are reviewed. Metal ions were determined by ESI-MS in negative-ion mode as monovalent negative ions of their aminopolycarboxylate (APC) complexes, where excess amounts of the APC agents were added to sample solutions. Among the APCs studied, we found trans-1,2-diaminocyclohexane-N,N,N',N'-tetraacetic acid (CyDTA, the chemical forms in a complex were expressed as H(n)cydta(n-4)) as the best chelating agent. A size exclusion column was used for on-line separation of the metal-APC complexes from matrix salts in samples. Total amounts of Al, Ni, Cu, Zn, and Pb in the biological certified reference materials (CRM), Olive Leaves (BCR-062) and Plankton (BCR-414), and in a soil CRM (JSAC-0401) were successfully determined by the proposed method. Halide ions (X- = F-, Cl-, Br- and I-) and cyanide (CN-) were determined by ESI-MS based on the formation of ternary complexes of metals, chelating agents and the analyte anions. Negative ions of the ternary complexes of group 13 elements, nitrilotriacetic acid (NTA, H(n)nta(n-3)), and halides, i.e., [AlF(nta)](-) for F-, and [InX(nta)](-) for other halides, were measured; the limits of detection (LODs) were 10 nmol dm(-3) for F-, 0.31 mu mol dm(-3) for Cl-, 3.8 nmol dm(-3) for Br-, and 1.6 nmol dm(-3) for I-, respectively. In the case of CN-, an LOD of 20 nmol dm(-3) was obtained based on measurements of the ternary complex of Cu-II, CN- and 4-(2-pyridylazo)resorcinol (PAR, H(n)par(n-2)), i.e., [63Cu(II)(CN)(par)](-) (m/z 302). Moreover, quantitative methods for Cr-VI and Cr-III by ESI-MS were developed, where HCrO4- (m/z 117) for Cr-VI and [Cr-III(cydta)](-) for Cr-III were used for measurements.
引用
收藏
页码:7 / 14
页数:8
相关论文
共 52 条
[21]   Quantification of Trace Elements in Natural Samples by Electrospray Ionization Mass Spectrometry with a Size-Exclusion Column Based on the Formation of Metal-Aminopolycarboxylate Complexes [J].
Hotta, Hiroki ;
Mori, Takayuki ;
Takahashi, Akira ;
Kogure, Yuta ;
Johno, Keita ;
Umemura, Tomonari ;
Tsunoda, Kin-ichi .
ANALYTICAL CHEMISTRY, 2009, 81 (15) :6357-6363
[22]  
Jessome LL, 2006, LC GC N AM, V24, P498
[23]   A review of recent trends in electrospray ionisation-mass spectrometry for the analysis of metal-organic ligand complexes [J].
Keith-Roach, Miranda J. .
ANALYTICA CHIMICA ACTA, 2010, 678 (02) :140-148
[24]  
Kragten J., 1978, Atlas of metal-ligand equilibria in aqueous solution
[25]   Combating matrix effects in LC/ESI/MS: The extrapolative dilution approach [J].
Kruve, Anneli ;
Leito, Ivo ;
Herodes, Koit .
ANALYTICA CHIMICA ACTA, 2009, 651 (01) :75-80
[26]   Ionization enhancement in atmospheric pressure chemical ionization and suppression in electrospray ionization between target drugs and stable-isotope-labeled internal standards in quantitative liquid chromatography/tandem mass spectrometry [J].
Liang, HR ;
Foltz, RL ;
Meng, M ;
Bennett, P .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (24) :2815-2821
[27]   Recent developments in cyanide detection: A review [J].
Ma, Jian ;
Dasgupta, Purnendu K. .
ANALYTICA CHIMICA ACTA, 2010, 673 (02) :117-125
[28]   Ternary complexes of Al3+ and F- with a third ligand [J].
Martin, RB .
COORDINATION CHEMISTRY REVIEWS, 1996, 149 :23-32
[29]   Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS [J].
Matuszewski, BK ;
Constanzer, ML ;
Chavez-Eng, CM .
ANALYTICAL CHEMISTRY, 2003, 75 (13) :3019-3030
[30]   Simultaneous derivatization and extraction of free cyanide in biological samples with home-made hollow fiber-protected headspace liquid-phase microextraction followed by capillary electrophoresis with UV detection [J].
Meng, Liang ;
Liu, Xin ;
Wang, Bin ;
Shen, Guijun ;
Wang, Zhengqiao ;
Guo, Ming .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (29) :3645-3651