Biomechanical Analysis of Stand-alone Lateral Lumbar Interbody Fusion for Lumbar Adjacent Segment Disease

被引:10
作者
Chioffe, Michael [1 ]
McCarthy, Michael [2 ]
Swiatek, Peter R. [3 ]
Maslak, Joseph P. [4 ]
Voronov, Leonard I. [5 ]
Havey, Robert M. [3 ]
Muriuki, Muturi [6 ]
Patwardhan, Avinash [7 ]
Patel, Alpesh A. [3 ]
机构
[1] Sarah Bush Lincoln Hlth Ctr, Orthopaed Surg, Mattoon, IL 61938 USA
[2] Hosp Special Surg, Orthoped Surg, Spine, 535 E 70th St, New York, NY 10021 USA
[3] Northwestern Mem Hosp, Orthopaed Surg, Chicago, IL 60611 USA
[4] Cleveland Clin, Orthopaed Surg, Spine, Cleveland, OH 44106 USA
[5] Loyola Univ Chicago, Orthopaed Surg, Maywood, IL USA
[6] Edward Hines Jr VA Hosp, Orthopaed Surg, Hines, IL USA
[7] Loyola Univ Med Ctr, Orthopaed Surg, Chicago, IL USA
关键词
interbody fusion; posterior spinal fusion; adjacent segment disease; spondylosis; biomechanics; INDIRECT DECOMPRESSION; SPINE FUSION; DEGENERATION; INSTRUMENTATION; OUTCOMES; STENOSIS;
D O I
10.7759/cureus.6208
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Study design Biomechanical cadaveric study Objective To compare biomechanical properties of a single stand-alone interbody fusion and a single-level pedicle screw construct above a previous lumbar pedicle fusion. Summary of background data Adjacent segment disease (ASD) is spondylosis of adjacent vertebral segments after previous spinal fusion. Despite the consensus that ASD is clinically significant, the surgical treatment of ASD is controversial. Methods Lateral lumbar interbody fusion (LLIF) and posterior spinal fusion (PSF) with pedicle screws were analyzed within a validated cadaveric lumbar fusion model. L3-4 vertebral segment motion was analyzed within the following simulations: without implants (intact), L3- 4 LLIF-only, L3-4 LLIF with previous L4-S1 PSF, L3-4 PSF with previous L4-S1 PSF, and L4-S1 PSF alone. L3-4 motion values were measured during flexion/extension with and without axial load, side bending, and axial rotation. Results L3-4 motion in the intact model was found to be 4.7 +/- 1.2 degrees. L3-4 LLIF-only decreased motion to 1.9 +/- 1.1 degrees. L3-4 LLIF with previous L4-S1 fusion demonstrated less motion in all planes with and without loading (p < 0.05) compared to an intact spine. However, L3-4 motion with flexion/extension and lateral bending was noted to be greater compared to the L3-S1 construct (p < 0.5). The L3-S1 PSF construct decreased motion to less than 1 degrees in all planes of motion with or without loading (p < 0.05). The L3-4 PSF with previous L4-S1 PSF constructs decreased the flexion/extension motion by 92.4% compared to the intact spine, whereas the L3-4 LLIF with previous L4-S1 PSF constructs decreased motion by 61.2%. Conclusions Stand-alone LLIF above a previous posterolateral fusion significantly decreases motion at the adjacent segment, demonstrating its utility in treating ASD without necessitating revision. The stand-alone LLIF is a biomechanically sound option in the treatment of ASD and is advantageous in patient populations who may benefit from less invasive surgical options.
引用
收藏
页数:10
相关论文
共 22 条
[1]  
Abbasi H, 2017, CUREUS J MED SCIENCE, V9, DOI 10.7759/cureus.979
[2]   Minimally invasive lateral retroperitoneal transpsoas interbody fusion for L4-5 spondylolisthesis: clinical outcomes [J].
Ahmadian, Amir ;
Verma, Sean ;
Mundis, Gregory M., Jr. ;
Oskouian, Rod J., Jr. ;
Smith, Donald A. ;
Uribe, Juan S. .
JOURNAL OF NEUROSURGERY-SPINE, 2013, 19 (03) :314-320
[3]   Single-Level Lateral Lumbar Interbody Fusion for the Treatment of Adjacent Segment Disease [J].
Aichmair, Alexander ;
Alimi, Marjan ;
Hughes, Alexander P. ;
Sama, Andrew A. ;
Du, Jerry Y. ;
Hartl, Roger ;
Burket, Jayme C. ;
Lampe, Lukas P. ;
Cammisa, Frank P. ;
Girardi, Federico P. .
SPINE, 2017, 42 (09) :E515-E522
[4]   Radiological and clinical outcomes following extreme lateral interbody fusion [J].
Alimi, Marjan ;
Hofstetter, Christoph P. ;
Cong, Guang-Ting ;
Tsiouris, Apostolos John ;
James, Andrew R. ;
Paulo, Danika ;
Elowitz, Eric ;
Haertl, Roger .
JOURNAL OF NEUROSURGERY-SPINE, 2014, 20 (06) :623-635
[5]   Adjacent segment hypermobility after lumbar spine fusion -: No association with progressive degeneration of the segment 5 years after surgery [J].
Axelsson, Paul ;
Johnsson, Ragnar ;
Stromqvist, Bjorn .
ACTA ORTHOPAEDICA, 2007, 78 (06) :834-839
[6]   Short-term outcomes of lateral lumbar interbody fusion without decompression for the treatment of symptomatic degenerative spondylolisthesis at L4-5 [J].
Campbell, Peter G. ;
Nunley, Pierce D. ;
Cavanaugh, David ;
Kerr, Eubulus ;
Utter, Philip Andrew ;
Frank, Kelly ;
Stone, Marcus .
NEUROSURGICAL FOCUS, 2018, 44 (01)
[7]   Indirect Decompression of Lumbar Stenosis With Transpsoas Interbody Cages and Percutaneous Posterior Instrumentation [J].
Castellvi, Antonio E. ;
Nienke, Thomas W. ;
Marulanda, German A. ;
Murtagh, Ryan D. ;
Santoni, Brandon G. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (06) :1784-1791
[8]   Adjacent segment disease following lumbar/thoracolumbar fusion with pedicle screw instrumentation - A minimum 5-year follow-up [J].
Cheh, Gene ;
Bridwell, Keith H. ;
Lenke, Lawrence G. ;
Buchowski, Jacob M. ;
Daubs, Michael D. ;
Kim, Yongjung ;
Baldus, Christy .
SPINE, 2007, 32 (20) :2253-2257
[9]   Risk factors for adjacent-segment failure following lumbar fixation with rigid instrumentation for degenerative instability [J].
Etebar, S ;
Cahill, DW .
JOURNAL OF NEUROSURGERY, 1999, 90 (04) :163-169
[10]   Biomechanics of lateral lumbar interbody fusion constructs with lateral and posterior plate fixation [J].
Fogel, Guy R. ;
Parikh, Rachit D. ;
Ryu, Stephen I. ;
Turner, Alexander W. L. .
JOURNAL OF NEUROSURGERY-SPINE, 2014, 20 (03) :291-297