Parametric study and optimization of a solar chimney passive ventilation system coupled with an earth-to-air heat exchanger

被引:59
作者
Serageldin, Ahmed A. [1 ,2 ]
Abdelrahman, Ali K. [2 ]
Ookawara, Shinichi [3 ]
机构
[1] Benha Univ, Shoubra Fac Engn, Banha, Egypt
[2] E JUST, Alexandria, Egypt
[3] Tokyo Inst Technol, Tokyo, Japan
关键词
Earth-air heat exchanger; Solar chimney; Parametric study; Numerical simulation; Optimization; THERMAL PERFORMANCE; NATURAL VENTILATION; COOLING SYSTEM; GREENHOUSE; BUILDINGS;
D O I
10.1016/j.seta.2018.10.010
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A parametric analysis and optimization method for passive heating and ventilation systems are developed, using the computational fluid dynamics (CFD) ANSYS design exploration and optimization tool. Moreover, a three-dimensional, quasi-steady CFD Fluent simulation is performed and validated against experimental results. For comparison, the thermal performance of a small-scale wooden room fitted with a solar chimney and an earth-toair heat exchanger (EAHE) was experimentally evaluated in the cold season in Egypt, in March 14-22, 2016. A good agreement has been found between the experimental and simulated results, with error, correlation coefficient, and coefficient of determination average values of 7.3%, 96.5%, and 94%, respectively. Moreover, a parametric study is conducted to maximize the ventilation rate, using eight parameters for solar chimney configuration (width, length, air gap, inclination angle, and position) and EAHE design (pipe diameter, inlet position, and inlet height). It is found that the EAHE pipe diameter is the most sensitive parameter, followed by chimney height, and EAHE inlet height and position; the solar chimney inclination angle, width, and gap have also noticeable impacts. The optimum chimney inclination angle, length, width, and gap ranges are 30-35 degrees, 1.94-1.97 m, 0.92-0.97 m, and 0.19-0.23 m, respectively.
引用
收藏
页码:263 / 278
页数:16
相关论文
共 29 条
[1]   A model for integrating passive and low energy airflow components into low rise buildings [J].
Alemu, Alemu T. ;
Saman, Wasim ;
Belusko, Martin .
ENERGY AND BUILDINGS, 2012, 49 :148-157
[2]   Experimental and numerical studies of solar chimney for natural ventilation in Iraq [J].
Amori, Karima E. ;
Mohammed, Saif Watheq .
ENERGY AND BUILDINGS, 2012, 47 :450-457
[3]  
ANSYS Inc, 2013, DES EXPL US GUID
[4]  
Ansys Inc, 2015, ANSYS FLUENT theory guide
[5]  
ANSYS Inc. Design of Experiments (DOE), 2013, DES EXP DOE INTR ANS, P1
[6]   The effect of solar chimney layout on ventilation rate in buildings [J].
Asadi, Somaye ;
Fakhari, Maryam ;
Fayaz, Rima ;
Mandaviparsa, Akram .
ENERGY AND BUILDINGS, 2016, 123 :71-78
[7]   Application of passive cooling systems in the hot and humid climate: The case study of solar chimney and wetted roof in Thailand [J].
Chungloo, Sudaporn ;
Limmeechokchai, Bundit .
BUILDING AND ENVIRONMENT, 2007, 42 (09) :3341-3351
[8]  
de Aguiar Peixoto R., 2005, REP SAFEGUARDING OZO, P269, DOI [10.2277/0521682061, DOI 10.2277/0521682061]
[9]   CFD analysis for solar chimney power plants [J].
Fasel, Hermann F. ;
Meng, Long ;
Shams, Ehsan ;
Gross, Andreas .
SOLAR ENERGY, 2013, 98 :12-22
[10]   Effects of "wall angularity of atrium" on "buildings natural ventilation and thermal performance" and CFD model [J].
Fini, Ali Shafiei ;
Moosavi, Ali .
ENERGY AND BUILDINGS, 2016, 121 :265-283