A Magnetic Resonance Compatible Soft Wearable Robotic Glove for Hand Rehabilitation and Brain Imaging

被引:84
作者
Yap, Hong Kai [1 ]
Kamaldin, Nazir [2 ]
Lim, Jeong Hoon [3 ]
Nasrallah, Fatima A. [4 ]
Goh, James Cho Hong [1 ]
Yeow, Chen-Hua [1 ,5 ,6 ]
机构
[1] Natl Univ Singapore, Dept Biomed Engn, Singapore 117583, Singapore
[2] Natl Univ Singapore, Dept Elect & Comp Engn, Singapore 117583, Singapore
[3] Natl Univ Singapore, Natl Univ Hosp, Yong Loo Lin Sch Med, Dept Med, Singapore 119228, Singapore
[4] Univ Queensland, Queensland Brain Inst, Brisbane, Qld 4072, Australia
[5] Singapore Inst Neurotechnol, Singapore, Singapore
[6] Adv Robot Ctr, Singapore, Singapore
关键词
Magnetic resonance compatible devices; magnetic resonance compatible soft actuators; magnetic resonance imaging; rehabilitation robotics; soft wearable robotics; MULTICENTER FMRI; NOISE-RATIO; DESIGN; STROKE; EXOSKELETON; ACTIVATION; ACTUATION; OPTIMIZATION; RECOVERY; THERAPY;
D O I
10.1109/TNSRE.2016.2602941
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this paper, we present the design, fabrication and evaluation of a soft wearable robotic glove, which can be used with functional Magnetic Resonance imaging (fMRI) during the hand rehabilitation and task specific training. The soft wearable robotic glove, called MR-Glove, consists of two major components: a) a set of soft pneumatic actuators and b) a glove. The soft pneumatic actuators, which are made of silicone elastomers, generate bending motion and actuate finger joints upon pressurization. The device is MR-compatible as it contains no ferromagnetic materials and operates pneumatically. Our results show that the device did not cause artifacts to fMRI images during hand rehabilitation and task-specific exercises. This study demonstrated the possibility of using fMRI and MR-compatible soft wearable robotic device to study brain activities and motor performances during hand rehabilitation, and to unravel the functional effects of rehabilitation robotics on brain stimulation.
引用
收藏
页码:782 / 793
页数:12
相关论文
共 57 条
[1]   An index finger exoskeleton with series elastic actuation for rehabilitation: Design, control and performance characterization [J].
Agarwal, Priyanshu ;
Fox, Jonas ;
Yun, Youngmok ;
O'Malley, Marcia K. ;
Deshpande, Ashish D. .
INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH, 2015, 34 (14) :1747-1772
[2]   The Effect of Lunate Morphology on the 3-Dimensional Kinematics of the Carpus [J].
Bain, Gregory I. ;
Clitherow, Harry D. S. ;
Millar, Stuart ;
Fraysse, Francois ;
Costi, John J. ;
Eng, Kevin ;
McGuire, Duncan T. ;
Thewlis, Dominic .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (01) :81-U294
[3]   Neural Plasticity After Acquired Brain Injury: Evidence from Functional Neuroimaging [J].
Chen, Haiwen ;
Epstein, Jane ;
Stern, Emily .
PM&R, 2010, 2 (12) :S306-S312
[4]   A Pneumatic Glove and Immersive Virtual Reality Environment for Hand Rehabilitative Training After Stroke [J].
Connelly, Lauri ;
Jia, Yicheng ;
Toro, Maria L. ;
Stoykov, Mary Ellen ;
Kenyon, Robert V. ;
Kamper, Derek G. .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2010, 18 (05) :551-559
[5]   FBG Sensing Glove for Monitoring Hand Posture [J].
da Silva, Alexandre Ferreira ;
Goncalves, Anselmo Filipe ;
Mendes, Paulo Mateus ;
Correia, Jose Higino .
IEEE SENSORS JOURNAL, 2011, 11 (10) :2442-2448
[6]  
Desborough L., 2002, AIChE Symposium Series, P169
[7]   Finite Element Analysis and Design Optimization of a Pneumatically Actuating Silicone Module for Robotic Surgery Applications [J].
Elsayed, Yahya ;
Vincensi, Augusto ;
Lekakou, Constantina ;
Geng, Tao ;
Saaj, C. M. ;
Ranzani, Tommaso ;
Cianchetti, Matteo ;
Menciassi, Arianna .
SOFT ROBOTICS, 2014, 1 (04) :255-262
[8]  
Erwin A, 2015, INT C REHAB ROBOT, P187, DOI 10.1109/ICORR.2015.7281197
[9]   Intraoperative magnetic resonance imaging-conditional robotic devices for therapy and diagnosis [J].
Fisher, Taylor ;
Hamed, Abbi ;
Vartholomeos, Panagiotis ;
Masamune, Ken ;
Tang, Guoyi ;
Ren, Hongliang ;
Tse, Zion T. H. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2014, 228 (03) :303-318
[10]  
Flueckiger M, 2005, IEEE IND APPLIC SOC, P2075