Electrospun Nylon6 Nanofibrous Membrane as SPE Adsorbent for the Enrichment and Determination of Three Estrogens in Environmental Water Samples

被引:60
作者
Xu, Qian [1 ,2 ]
Wu, Shu-Yan [1 ]
Wang, Min [1 ]
Yin, Xue-Yan [1 ]
Wen, Zuo-Yang [2 ]
Ge, Wen-Na [1 ]
Gu, Zhong-Ze [2 ]
机构
[1] Southeast Univ, Sch Publ Hlth, Nanjing 210009, Peoples R China
[2] Southeast Univ, State Key Lab Bioelect, Nanjing 210096, Peoples R China
关键词
Column liquid chromatography-ultraviolet detector; Solid membrane extraction; Water analysis; Electrospinning; Nylon6 nanofibrous membrane; SOLID-PHASE EXTRACTION; POLYMER NANOFIBERS; AQUEOUS-SOLUTION; POLLUTANTS; SORBENT; HEALTH;
D O I
10.1365/s10337-009-1453-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this paper, electrospun Nylon6 nanofibrous membrane was firstly used as adsorbent for solid membrane extraction (SME). The membrane was arranged as a disk in a home-made device, three estrogens-estradiol (E2), ethinylestradiol (EE2) and estrone (E1) in environmental water were extracted and then determined by liquid chromatography-ultraviolet detector (LC-UV). The important parameters affecting extraction efficiency were completely studied and optimized. The experimental results showed that only 1.5 mg Nylon6 nanofibrous membrane could make the maximum sample loading volume up to 50 mL and the target analytes were adsorbed effectively. Under the optimized conditions, the limits of detection (LOD) for E2, EE2, E1 were up to 0.05, 0.08, 0.17 ng mL(-1) respectively and the repeatabilities (RSD%) of intra-membrane and inter-membrane were below 6.0% about spiked samples. The proposed method was subsequently applied to studying water samples from river, rain, pond and tap. Satisfactory spiked recoveries in the range of 85.3-95.9% at 0.25 ng mL(-1) spiked level for the three estrogens were obtained. A comparison with commercial nylon microporous membrane and octadecylsilica (ODS) cartridges was also carried out. All the results showed that electrospun Nylon6 nanofibrous membrane, as a new adsorbent material has great potential for the enrichment of steroid estrogens in the water samples with satisfactory recovery and repeatability.
引用
收藏
页码:487 / 492
页数:6
相关论文
共 25 条
[1]  
AMALIA GP, 2006, ANALYST, V131, P407
[2]   A novel application of nylon membranes to the luminescent determination of benzo[a]pyrene at ultra trace levels in water samples [J].
Bortolato, S. A. ;
Arancibia, J. A. ;
Escandar, G. M. .
ANALYTICA CHIMICA ACTA, 2008, 613 (02) :218-227
[3]   Chemometrics-Assisted Excitation-Emission Fluorescence Spectroscopy on Nylon Membranes. Simultaneous Determination of Benzo[a]pyrene and Dibenz[a,h]anthracene at Parts-Per-Trillion Levels in the Presence of the Remaining EPA PAH Priority Pollutants As Interferences [J].
Bortolato, Santiago A. ;
Arancibia, Juan A. ;
Escandar, Graciela M. .
ANALYTICAL CHEMISTRY, 2008, 80 (21) :8276-8286
[4]   Determination of sixteen polycyclic aromatic hydrocarbons in aqueous and solid samples from an Italian wastewater treatment plant [J].
Busetti, F ;
Heitz, A ;
Cuomo, M ;
Badoer, S ;
Traverso, P .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1102 (1-2) :104-115
[5]   DEVELOPMENTAL EFFECTS OF ENDOCRINE-DISRUPTING CHEMICALS IN WILDLIFE AND HUMANS [J].
COLBORN, T ;
SAAL, FSV ;
SOTO, AM .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1993, 101 (05) :378-384
[6]   ENVIRONMENTAL ESTROGENS - HEALTH IMPLICATIONS FOR HUMANS AND WILDLIFE [J].
COLBORN, T .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1995, 103 :135-136
[7]   Multiresidue analysis of organic pollutants in water by SPE with a C8 and SDVB combined cartridge [J].
Davì, ML ;
Liboni, M ;
Malfatto, MG .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1999, 74 (1-4) :155-166
[8]   Liquid chromatography-(tandem) mass spectrometry of selected emerging pollutants (steroid sex hormones, drugs and alkylphenolic surfactants) in the aquatic environment [J].
de Alda, MJL ;
Díaz-Cruz, S ;
Petrovic, M ;
Barceló, D .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1000 (1-2) :503-526
[9]  
de Alda MJL, 2001, J CHROMATOGR A, V938, P145, DOI 10.1016/S0021-9673(01)01223-7
[10]   Determination of carbamazepine in serum and pharmaceutical preparations using immobilization on a nylon support and fluorescence detection [J].
Escandar, GM ;
Gómez, DG ;
Mansilla, AE ;
de la Peña, AM ;
Goicoechea, HC .
ANALYTICA CHIMICA ACTA, 2004, 506 (02) :161-170