A vibratory device to accelerate orthodontic tooth movement

被引:0
作者
Ghiasabadi, Mahboubeh [1 ]
Farahani, Abolfazl [2 ]
Farahani, Mohammad Hossein [3 ]
机构
[1] Private Off, Arak, Markazi Provinc, Iran
[2] Univ Tehran Med Sci, Sch Dent, Oral & Maxillofacial Surg, Tehran, Iran
[3] Orthodont Private Off, Karaj, Alborz Province, Iran
来源
PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES | 2021年 / 15卷 / 01期
关键词
respectively; Vibrator; Orthodontic tooth movement; 3D printing; IN-VIVO; BONE; STIMULATION; RESPONSES; FORCE;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aim: Several approaches have been proposed to accelerate orthodontic tooth movements. One of these technologies is vibrating devices, including the Acceledent device. In this research project, a device similar to the Acceledent device has been designed and fabricated. The therapeutic goal of this device is to promote of orthodontic tooth movement by produce determined vibrations. Methods: This device consists of the following components: 1- electronic circuit board 2- the body 3- the oral piece 4- the engine and crank wheel 5- rechargeable battery 6- PID control algorithm (proportional-integralderivative) which calculates the error rate by controlling the output and input values of the process, and corrects the motion and vibration values of the system by sending a signal. Results: In this device, there is a mechanical vibrations with a frequency of 30 Hz and a force of 0.25 N which the patient will use it for 20 minutes daily. These mechanical vibrations are transmitted to the patient through an oral piece. Garter spring as the interface between the oral piece and the body of the device is responsible for transmitting the vibration from the body to the oral piece. The crankshaft attaching to the electromotor produces the vibration by centrifugal rotation. The PTC Creo 6.0 software was used to designing the body, and 3D printing technology to fabricating the body. Conclusion: Th whole process of design and prototype production of the Acceledent device were performed during two years. Laboratory evaluations indicated a frequency and a force of the device equal to 30 Hz and 0.25 N, respectively.
引用
收藏
页码:615 / 619
页数:5
相关论文
共 33 条
[1]   Clinical outcomes for patients finished with the SureSmile™ method compared with conventional fixed orthodontic therapy [J].
Alford, Timothy J. ;
Roberts, W. Eugene ;
Hartsfield, James K., Jr. ;
Eckert, George J. ;
Snyder, Ronald J. .
ANGLE ORTHODONTIST, 2011, 81 (03) :383-388
[2]   Osteogenic Effect of High-frequency Acceleration on Alveolar Bone [J].
Alikhani, M. ;
Khoo, E. ;
Alyami, B. ;
Raptis, M. ;
Salgueiro, J. M. ;
Oliveira, S. M. ;
Boskey, A. ;
Teixeira, C. C. .
JOURNAL OF DENTAL RESEARCH, 2012, 91 (04) :413-419
[3]   Effect of micro-osteoperforations on the rate of tooth movement [J].
Alikhani, Mani ;
Raptis, Markos ;
Zoldan, Billie ;
Sangsuwon, Chinapa ;
Lee, Yoo B. ;
Alyami, Bandar ;
Corpodian, Corey ;
Barrera, Luz M. ;
Alansari, Sarah ;
Khoo, Edmund ;
Teixeira, Cristina .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2013, 144 (05) :639-648
[4]   ROOT RESORPTION AFTER LOCAL INJECTION OF PROSTAGLANDIN-E2 DURING EXPERIMENTAL TOOTH MOVEMENT [J].
BRUDVIK, P ;
RYGH, P .
EUROPEAN JOURNAL OF ORTHODONTICS, 1991, 13 (04) :255-263
[5]   Effects of low-intensity laser therapy on the orthodontic movement velocity of human teeth: A preliminary study [J].
Cruz, DR ;
Kohara, EK ;
Ribeiro, MS ;
Wetter, NU .
LASERS IN SURGERY AND MEDICINE, 2004, 35 (02) :117-120
[6]   ELECTRIC CURRENTS, BONE REMODELING, AND ORTHODONTIC TOOTH MOVEMENT .2. INCREASE IN RATE OF TOOTH MOVEMENT AND PERIODONTAL CYCLIC-NUCLEOTIDE LEVELS BY COMBINED FORCE AND ELECTRIC-CURRENT [J].
DAVIDOVITCH, Z ;
FINKELSON, MD ;
STEIGMAN, S ;
SHANFELD, JL ;
MONTGOMERY, PC ;
KOROSTOFF, E .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1980, 77 (01) :33-47
[7]   Does timing of implant placement affect esthetic results in single-tooth implants? A cohort evaluation based onmPES [J].
Ghahroudi, Amir A. R. ;
Rokn, Amir R. ;
Shamshiri, Ahmad R. ;
Samiei, Nazanin .
JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2020, 32 (07) :715-725
[8]   Effectiveness of non-conventional methods for accelerated orthodontic tooth movement: A systematic review and meta-analysis [J].
Gkantidis, Nikolaos ;
Mistakidis, Ilias ;
Kouskoura, Thaleia ;
Pandis, Nikolaos .
JOURNAL OF DENTISTRY, 2014, 42 (10) :1300-1319
[9]   Mechanical loading stimulates dentin matrix protein 1 (DMP1) expression in osteocytes in vivo [J].
Gluhak-Heinrich, J ;
Ye, L ;
Bonewald, LF ;
Feng, JQ ;
MacDougall, M ;
Harris, SE ;
Pavlin, D .
JOURNAL OF BONE AND MINERAL RESEARCH, 2003, 18 (05) :807-817
[10]  
Graber LW., 2017, Orthodontics: current principles and techniques, VSixth