Blood plasma separation and extraction from a minute amount of blood using dielectrophoretic and capillary forces

被引:93
作者
Nakashima, Yuta [1 ]
Hata, Sakiko [1 ]
Yasuda, Takashi [1 ]
机构
[1] Kyushu Inst Technol, Grad Sch Life Sci & Syst Engn, Wakamatsu Ku, Fukuoka 8080196, Japan
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2010年 / 145卷 / 01期
关键词
Dielectrophoresis; Blood separation; Blood plasma extraction; Capillary force; CELL-SEPARATION; WHOLE-BLOOD; PARTICLE SEPARATION; AC ELECTROKINETICS; CHIP; FLOW; SYSTEM;
D O I
10.1016/j.snb.2009.11.070
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper presents a microfluidic device that can separate and extract blood plasma from several microliters of blood without external mechanical driving sources such as a centrifugal machine and a syringe pump. This device consists of a main-channel, many side-channels, a reservoir, and two electrodes. After blood was automatically injected into the main-channel by capillary force, blood cells blocked the side-channel entrances and prevented blood plasma from entering them. Next, when AC voltage application between the two electrodes separated blood into cells and plasma by dielectrophoresis (DEP), cells were removed from the side-channel entrances. This permitted plasma to be injected into the side-channels connecting to the reservoir. Experiments using diluted blood samples (dilution 1:9) showed that blood cell removal and blood plasma extraction were affected by channel geometry and magnitude/frequency of applied AC voltage. In case of applied AC voltage of 10 V and 1 MHz, blood cells were removed by about 97%, and blood plasma of about 300 nL was extracted from 5 mu L. blood. Moreover, we found that optimal dimension of the side-channels for blood plasma extraction is 5 mu m wide and 2 mu m deep. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:561 / 569
页数:9
相关论文
共 41 条
[1]  
ALTENDORF E, 1998, P MICROTAS BANFF CAN
[2]  
[Anonymous], 1978, CAMBRIDGE MONOGRAPHS
[3]   Quantitative assessment of dielectrophoresis as a micro fluidic retention and separation technique for beads and human blood erythrocytes [J].
Auerswald, J ;
Knapp, HF .
MICROELECTRONIC ENGINEERING, 2003, 67-8 :879-886
[4]  
BLATTERT C, 2006, P MICROTAS TOK JAP N
[5]  
BRENNER T, 2004, P MICROTAS MALM SWED
[6]  
Chen DF, 2007, SENSOR ACTUAT A-PHYS, V133, P329, DOI 10.1016/j.sna.2006.06.029
[7]   Microfluidic chip for blood cell separation and collection based on crossflow filtration [J].
Chen, Xing ;
Cui, Da Fu ;
Liu, Chang Chun ;
Li, Hui .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 130 (01) :216-221
[8]   Microfluidic system for dielectrophoretic separation based on a trapezoidal electrode array [J].
Choi, S ;
Park, JK .
LAB ON A CHIP, 2005, 5 (10) :1161-1167
[9]   Isolation of plasma from whole blood using planar microfilters for lab-on-a-chip applications [J].
Crowley, TA ;
Pizziconi, V .
LAB ON A CHIP, 2005, 5 (09) :922-929
[10]   A continuous cell separation chip using hydrodynamic dielectrophoresis (DEP) process [J].
Doh, I ;
Cho, YH .
SENSORS AND ACTUATORS A-PHYSICAL, 2005, 121 (01) :59-65