Energy Efficiency and Environmental Impact Analyses of Supermarket Refrigeration Systems

被引:0
作者
Fricke, Brian A. [1 ]
Bansal, Pradeep K. [1 ]
Zha, Shitong [2 ]
机构
[1] Oak Ridge Natl Lab, Energy & Transportat Sci Div, Oak Ridge, TN 37830 USA
[2] Hill Phoenix, Refrigerat Syst Div, Covington, GA USA
来源
2013 ASHRAE ANNUAL CONFERENCE | 2013年
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents energy and die cycle climate performance (LCCP) analyses of a variety of supermarket refrigeration systems to identify designs that exhibit low environmental impact and high energy efficiency. EnergyPlus was used to model refrigeration systems in a variety of climate zones across the United States. The refrigeration systems that were modeled include the traditional multiplex DX system, cascade systems with secondary loops and the transcritical CO2 system. Furthermore, a variety of refrigerants were investigated, including R-32, R-134a, R-404A, R-1234yf, R-717 , and R-744. LCCP analysis was used to determine the direct and indirect carbon dioxide emissions resulting from the operation of the various refrigeration systems over their lifetimes. Our analysis revealed that high-efficieng supermarket referigeration systems may result in up to 44% less energy consumption and 78% reduced carbon dioxide emissions compared to the baseline multiplex DX system. This is an encouraging result for legislators, policy makers and supermarket owners to select low emission, high-efficieng commercial refrigeration system designs for future retrofit and new projects.
引用
收藏
页数:8
相关论文
共 11 条
[1]  
[Anonymous], 2010, 2010 INT S NEXT GEN
[2]  
ASHRAE SI, 2009, ASHRAE HDB FUND
[3]  
Deru M., 2007, NRELTP55038617, P1, DOI DOI 10.2172/884990
[4]  
Hafner A., 2004, MOBILE AIR CONDITION
[5]  
Johnson C, 2004, 15 ANN EARTH TECHN F
[6]   GREEN-MAC-LCCP: A Tool for Assessing the Life Cycle Climate Performance of MAC Systems [J].
Papasavva, Stella ;
Hill, William R. ;
Andersen, Stephen O. .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2010, 44 (19) :7666-7672
[7]  
Spatz M., 2008, 2008 SAE ALT REFR SY
[8]   An evaluation of options for replacing HCFC-22 in medium temperature refrigeration systems [J].
Spatz, MW ;
Motta, SFY .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (05) :475-483
[9]  
USDOE, 2010, HIGH PERF HOM TECHN
[10]  
USDOE, 2012, ENERGYPLUS