A study on the dosimetric accuracy of treatment planning for stereotactic body radiation therapy of lung cancer using average and maximum intensity projection images

被引:48
作者
Huang, Long [1 ]
Park, Kwangyoul [1 ]
Boike, Thomas [1 ]
Lee, Pam [1 ]
Papiez, Lech [1 ]
Solberg, Timothy [1 ]
Ding, Chuxiong [1 ]
Timmerman, Robert D. [1 ]
机构
[1] Univ Texas SW Med Ctr Dallas, Dept Radiat Oncol, Dallas, TX 75390 USA
关键词
4DCT; MIP; Stereotactic body radiotherapy; Dosimetry; Lung cancer; INTERNAL TARGET VOLUME; RADIOTHERAPY; MOTION; TUMORS; 4D-CT; SCANS; PHASE; 4DCT; MIP;
D O I
10.1016/j.radonc.2010.04.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To assess the accuracy of current stereotactic body radiation therapy (SBRT) lung treatment planning methodologies on irregular breathing patterns, we have performed a systematic dosimetric evaluation in phantoms by utilizing maximum intensity projection (MIP) and average (AVG) images generated from four dimensional computed tomography (4DCT). Methods: A custom built programmable lung phantom was used to simulate tumor motions due to various breathing patterns of patients. 4DCT scans were obtained in helical mode, and reconstructed AVG and MIP datasets were imported into the Pinnacle 8.0 h treatment planning system. SBRT plans were generated and executed, and delivered doses were measured by radiochromic film for analysis. Results: For targets moving regularly or irregularly within a small range (7.0 +/- 1.8 mm, n = 6), we observed good agreement between the measured and computed dose distributions. However, for targets moving irregularly with a larger range (20.8 +/- 2.6 mm, n = 4), the measured isodose lines were found to be shifted relative to the planned distribution, resulting in an under-dosing (over 10%) in a portion of the PTV. We further observed that the discrepancy between planned and measured dose distribution is due to the inaccurate representation of irregular target motion in the MIP images generated from 4DCT. Conclusions: Caution should be used when planning from 4DCT images in the presence of large and irregular target motion. The inaccuracy inherent in 4DCT MIP and AVG images can be mitigated through the application of methodologies to reduce respiratory motion, such as abdominal compression, and through the use of volumetric image guidance (e.g., cone beam CT - CBCT) to assure precise targeting with minimal shifts. Published by Elsevier Ireland Ltd. Radiotherapy and Oncology 96 (2010) 48-54
引用
收藏
页码:48 / 54
页数:7
相关论文
共 22 条
[1]   Dose calculations accounting for breathing motion in stereotactic lung radiotherapy based on 4D-CT and the internal target volume [J].
Admiraal, Marjan A. ;
Schuring, Danny ;
Hurkmans, Coen W. .
RADIOTHERAPY AND ONCOLOGY, 2008, 86 (01) :55-60
[2]   Comparison of helical, maximum intensity projection (MIP), and averaged intensity (Al) 4D CT imaging for stereotactic body radiation therapy (SBRT) planning in lung cancer [J].
Bradley, Jeffrey D. ;
Nofal, Ahmed N. ;
El Naqa, Issam M. ;
Lu, Wei ;
Liu, Jubei ;
Hubenschmidt, James ;
Low, Daniel A. ;
Drzymala, Robert E. ;
Khullar, Divya .
RADIOTHERAPY AND ONCOLOGY, 2006, 81 (03) :264-268
[3]   Estimation of error in maximal intensity projection-based internal target volume of lung tumors: A simulation and comparison study using dynamic magnetic resonance imaging [J].
Cai, Jing ;
Read, Paul W. ;
Baisden, Joseph M. ;
Larner, James M. ;
Benedict, Stanley H. ;
Sheng, Ke .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03) :895-902
[4]   Four-dimensional treatment planning for stereotactic body radiotherapy [J].
Guckenberger, Matthias ;
Wilbert, Juergen ;
Krieger, Thomas ;
Richter, Anne ;
Baier, Kurt ;
Meyer, Juergen ;
Flentje, Michael .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (01) :276-285
[5]   Four-dimensional computed tomography scan analysis of tumor and organ motion at varying levels of abdominal compression during stereotactic treatment of lung and liver [J].
Heinzerling, John H. ;
Anderson, John F. ;
Papiez, Lech ;
Boike, Thomas ;
Chien, Stanley ;
Zhang, Geoffrey ;
Abdulrahman, Ramzi ;
Timmerman, Robert .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (05) :1571-1578
[6]   Assessment of two novel ventilatory surrogates for use in the delivery of gated/tracked radiotherapy for non-small cell lung cancer [J].
Hughes, Simon ;
McClelland, James ;
Tarte, Segolene ;
Lawrence, David ;
Ahmad, Shahreen ;
Hawkes, David ;
Landau, David .
RADIOTHERAPY AND ONCOLOGY, 2009, 91 (03) :336-341
[7]   Changes in the respiratory pattern during radiotherapy for cancer in the lung [J].
Hugo, G ;
Vargas, C ;
Liang, J ;
Kestin, L ;
Wong, JW ;
Yan, D .
RADIOTHERAPY AND ONCOLOGY, 2006, 78 (03) :326-331
[8]  
[International Commission on Radiation Units and Measurements ICRU Report 62], 1999, 621999 ICRU
[9]   Acquiring 4D thoracic CT scans using a multislice helical method [J].
Keall, PJ ;
Starkschall, G ;
Shukla, H ;
Forster, KM ;
Ortiz, V ;
Stevens, CW ;
Vedam, SS ;
George, R ;
Guerrero, T ;
Mohan, R .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (10) :2053-2067
[10]   A technique for the quantitative evaluation of dose distributions [J].
Low, DA ;
Harms, WB ;
Mutic, S ;
Purdy, JA .
MEDICAL PHYSICS, 1998, 25 (05) :656-661