Simultaneous determination of 2-nitrophenol and 4-nitrophenol based on the multi-wall carbon nanotubes nafion-modified electrode

被引:116
作者
Huang, WS [1 ]
Yang, CH [1 ]
Zhang, SH [1 ]
机构
[1] Hubei Inst Natl, Dept Chem, Hubei 445000, Peoples R China
关键词
carbon nanotubes; nafion; chemically modified electrodes; 2-nitrophenol; 4-nitrophenol;
D O I
10.1007/s00216-002-1745-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, multi-wall carbon nanotubes (MWNT) were conveniently dispersed into Nafion-ethanol solution, and the MWNT-Nafion-modified glassy carbon electrode (GCE) was described for the simultaneous determination of 2-nitrophenol and 4-nitrophenol. At pH 4.0 phosphate buffer, the reduction peak currents of 2-nitrophenol (at -0.8 V) and 4-nitrophenol (at -1.0 V) increase significantly at the MWNT-Nafion-modified GCE, in comparison with that at the Nafion-modified GCE and the bare GCE. The experimental parameters, such as solution pH of phosphate buffer, accumulation potential and time, and the amounts of MWNT-Nafion onto the GCE surface, were optimized. The reduction peak currents are linear with the concentration of 2-nitrophenol from 5x10(-8) to 1x10(-5) mol L-1 and with that of 4-nitrophenol from 1x10(-7) to 1x10(-5) mol L-1. The detection limits after 3-min accumulation are 1x10(-8)moI L-1 for 2-nitrophenol and for 4x10(-8) mol L-1 for 4-nitrophenol. This modified electrode was applied to direct determination of 2-nitrophenol and 4-nitrophenol in lake water samples.
引用
收藏
页码:703 / 707
页数:5
相关论文
共 15 条
[1]   Carbon nanotube electrode for oxidation of dopamine [J].
Britto, PJ ;
Santhanam, KSV ;
Ajayan, PM .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1996, 41 (01) :121-125
[2]  
Cordero-Rando MD, 1999, MIKROCHIM ACTA, V132, P7
[3]   Protein electrochemistry at carbon nanotube electrodes [J].
Davis, JJ ;
Coles, RJ ;
Hill, HAO .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1997, 440 (1-2) :279-282
[4]   VOLTAMMETRIC DETERMINATION OF METHYL PARATHION, ORTHO, META AND PARA NITROPHENOL WITH A CARBON PASTE ELECTRODE MODIFIED WITH C-18 [J].
HERNANDEZ, L ;
HERNANDEZ, P ;
VICENTE, J .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 345 (11) :712-715
[5]   Voltammetric determination of 4-nitrophenol at a sodium montmorillonite-anthraquinone chemically modified glassy carbon electrode [J].
Hu, SS ;
Xu, CL ;
Wang, GP ;
Cui, DF .
TALANTA, 2001, 54 (01) :115-123
[6]   HELICAL MICROTUBULES OF GRAPHITIC CARBON [J].
IIJIMA, S .
NATURE, 1991, 354 (6348) :56-58
[7]   Investigation of the electrochemical and electrocatalytic behavior of single-wall carbon nanotube film on a glassy carbon electrode [J].
Luo, HX ;
Shi, ZJ ;
Li, NQ ;
Gu, ZN ;
Zhuang, QK .
ANALYTICAL CHEMISTRY, 2001, 73 (05) :915-920
[8]   Voltammetric determination of 2-nitrophenol at a bentonite-modified carbon paste electrode [J].
Rodriguez, IN ;
Zamora, MB ;
Salvador, JMB ;
Leyva, JAM ;
HernandezArtiga, MP ;
deCisneros, JLHH .
MIKROCHIMICA ACTA, 1997, 126 (1-2) :87-92
[9]   Use of a carbon paste modified electrode for the determination of 2-nitrophenol in a flow system by differential pulse voltammetry [J].
Rodriguez, IN ;
Leyva, JAM ;
deCisneros, JLHH .
ANALYTICA CHIMICA ACTA, 1997, 344 (03) :167-173
[10]   High-performance liquid chromatographic determination of phenol, 4-nitrophenol, beta-naphthol and a number of their glucuronide and sulphate conjugates in organ perfusate [J].
Thompson, MJ ;
Ballinger, LN ;
Cross, SE ;
Roberts, MS .