The Freiburg Visual Acuity test - Automatic measurement of visual acuity

被引:791
|
作者
Bach, M
机构
[1] Universitäts-Augenklinik, Elektrophysiologisches Labor, Freiburg
[2] Universitäts-Augenklinik, Elektrophysiologisches Labor
关键词
visual acuity; computer test; psychometric threshold estimation;
D O I
10.1097/00006324-199601000-00008
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The Freiburg Visual Acuity test is an automated procedure for self-administered measurement of visual acuity. Landolt-Cs are presented on a monitor in one of eight orientations. The subject presses one of eight buttons, which are spatially arranged on a response box according to the eight possible positions of the Landolt-Cs' gap. To estimate the acuity threshold, a best PEST (best Parameter Estimation by Sequential Testing) procedure is used in which a psychometric function having a constant slope on a logarithmic acuity scale is assumed. Measurement terminates after a fixed number of trials. With computer monitors, pixel-discreteness artifacts limit the presentation of small stimuli. By using anti-aliasing, i.e., smoothing of contours by multiple gray levels, the spatial resolution was improved by a factor of four. Thus, even the shape of small Landolt-Cs with oblique gaps is adequate and visual acuities from 5/80 (0.06) up to 5/1.4 (3.6) can be tested at a distance of 5 m.
引用
收藏
页码:49 / 53
页数:5
相关论文
共 50 条
  • [31] Establishing an Objective Measurement of Visual Acuity with a Computerised Optokinetic Nystagmus Suppression Test
    Schwob, Noemie
    Palmowski-Wolfe, Anja
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2020, 237 (04) : 502 - 505
  • [32] Time Controlled Visual Acuity - Repeatability and Its Relation to Conventional Visual Acuity
    Maissa, C. A.
    Guillon, M.
    Wong, S.
    Lebois, C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [33] Estimating visual acuity by character counting using the Snellen visual acuity chart
    Levy, AH
    McCulley, TJ
    Lam, BL
    Feuer, WJ
    EYE, 2005, 19 (06) : 622 - 624
  • [34] Estimating visual acuity by character counting using the Snellen visual acuity chart
    A H Levy
    T J McCulley
    B L Lam
    W J Feuer
    Eye, 2005, 19 : 622 - 624
  • [35] The automatic processing of visual information at different visual acuity levels: An ERP study
    Meng, Huanhuan
    Ji, Mengmeng
    Luo, Bin
    Zhang, Mingyang
    Gao, Yuan
    Ma, Lu
    Shen, Xi
    Luo, Chengliang
    Yang, Xun
    Chen, Xiping
    Tao, Luyang
    INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 2015, 98 (01) : 135 - 142
  • [36] Discrepancy between Visual Acuity and Microperimetry in AMD Patients: Visual Acuity Appears as an Inadequate Parameter to Test Macular Function
    Tran, B. -K.
    Herbort, C. P., Jr.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2015, 232 (04) : 529 - 532
  • [37] Vergleich zweier Visustests in der EinschulungsuntersuchungE‑Haken-Einblickgerät versus Freiburger VisustestComparison of two visual acuity tests in school enrolment examinationsTumbling E test versus Freiburg visual acuity test
    M. Bach
    M. Reuter
    W. A. Lagrèze
    Der Ophthalmologe, 2016, 113 : 684 - 689
  • [38] Visual Acuity, Near Visual Acuity, and Reading Acuity in Young and Old Subjects Under Photopic and Mesopic Illumination
    Johnston, P.
    Byrnes, M. J.
    Saigal, S.
    Sena, D. R. Figueiredo
    Torkildsen, G.
    Ingerman, A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [39] Assessment of Peripheral Visual Acuity in Different Test Conditions
    Belokopytov A.V.
    Rozhkova G.I.
    Gracheva M.A.
    Neuroscience and Behavioral Physiology, 2022, 52 (5) : 747 - 756
  • [40] Validation of a Standardized Home Visual Acuity Test for Teleophthalmology
    Siktberg, Jonathan
    Hamdan, Saif
    Liu, Yuhan
    Chen, Qingxia
    Donahue, Sean P.
    Patel, Shriji N.
    Sternberg, Paul, Jr.
    Robinson, Joshua
    Kammer, Jeffrey A.
    Gangaputra, Sapna S.
    OPHTHALMOLOGY SCIENCE, 2021, 1 (01):