The Freiburg Visual Acuity test - Automatic measurement of visual acuity

被引:791
|
作者
Bach, M
机构
[1] Universitäts-Augenklinik, Elektrophysiologisches Labor, Freiburg
[2] Universitäts-Augenklinik, Elektrophysiologisches Labor
关键词
visual acuity; computer test; psychometric threshold estimation;
D O I
10.1097/00006324-199601000-00008
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The Freiburg Visual Acuity test is an automated procedure for self-administered measurement of visual acuity. Landolt-Cs are presented on a monitor in one of eight orientations. The subject presses one of eight buttons, which are spatially arranged on a response box according to the eight possible positions of the Landolt-Cs' gap. To estimate the acuity threshold, a best PEST (best Parameter Estimation by Sequential Testing) procedure is used in which a psychometric function having a constant slope on a logarithmic acuity scale is assumed. Measurement terminates after a fixed number of trials. With computer monitors, pixel-discreteness artifacts limit the presentation of small stimuli. By using anti-aliasing, i.e., smoothing of contours by multiple gray levels, the spatial resolution was improved by a factor of four. Thus, even the shape of small Landolt-Cs with oblique gaps is adequate and visual acuities from 5/80 (0.06) up to 5/1.4 (3.6) can be tested at a distance of 5 m.
引用
收藏
页码:49 / 53
页数:5
相关论文
共 50 条
  • [1] The automatic 'Freiburg Visual Acuity Test' used before and after cataract surgery
    Rover, J
    Bornkessel, HC
    Nisius, A
    Bach, M
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1996, 209 (05) : 315 - 316
  • [2] Visual acuity testing in diabetic subjects: the decimal progression chart versus the Freiburg visual acuity test
    Lars Loumann Knudsen
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2003, 241 : 615 - 618
  • [3] Visual acuity testing in diabetic subjects: the decimal progression chart versus the Freiburg visual acuity test
    Knudsen, LL
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2003, 241 (08) : 615 - 618
  • [4] Visual acuity measured via the Freiburg Visual Acuity Test (FVT), Bailey Lovie Chart and Landolt Ring Chart
    Wesemann, W
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2002, 219 (09) : 660 - 667
  • [5] Comparison of two visual acuity tests in school enrolment examinations. Tumbling E test versus Freiburg visual acuity test
    Bach, M.
    Reuter, M.
    Lagreze, W. A.
    OPHTHALMOLOGE, 2016, 113 (08): : 684 - 689
  • [6] Resolving the clinical acuity categories "hand motion" and "counting fingers" using the Freiburg Visual Acuity Test (FrACT)
    Lange, C.
    Feltgen, N.
    Junker, B.
    Schulze-Bonsel, K.
    Bach, M.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2009, 247 (01) : 137 - 142
  • [7] Resolving the clinical acuity categories “hand motion” and “counting fingers” using the Freiburg Visual Acuity Test (FrACT)
    C. Lange
    N. Feltgen
    B. Junker
    K. Schulze-Bonsel
    M. Bach
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2009, 247 : 137 - 142
  • [8] Repeatability of visual acuity measurement
    Raasch, TW
    Bailey, IL
    Bullimore, MA
    OPTOMETRY AND VISION SCIENCE, 1998, 75 (05) : 342 - 348
  • [9] Validation of the DYOP visual acuity test
    Gantz, Liat
    Paritzky, Dinah
    Wunch, Inbar
    Kageyama, Andrew H.
    Wolf, Nadav
    Cherny, Christina
    Rosen, Mark
    JOURNAL OF OPTOMETRY, 2023, 16 (04) : 268 - 276
  • [10] A test of the visual acuity of the locust eye
    Catton, WT
    JOURNAL OF INSECT PHYSIOLOGY, 1998, 44 (12) : 1145 - 1148