dispersive liquid-liquid microextraction; experimental design; 2-mercaptobenzimidazole; preconcentration; UV-Vis spectrophotometry; CENTRAL COMPOSITE DESIGN; SIMULTANEOUS SPECTROPHOTOMETRIC DETERMINATION; ULTRASONIC-ASSISTED ADSORPTION; FLOATING ORGANIC DROP; THYREOSTATIC RESIDUES; GAS CHROMATOGRAPHY; ANIMAL TISSUE; SAMPLES; WATER; OPTIMIZATION;
D O I
10.1002/jssc.201601453
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method was developed to determine 2-mercaptobenzimidazole in water and urine samples using dispersive liquid-liquid microextraction technique coupled with ultraviolet-visible spectrophotometry. It was essential to peruse the effect of all parameters that can likely influence the performance of extraction. The influence of parameters, such as dispersive and extraction solvent volume and sample volume, on dispersive liquid-liquid microextraction was studied. The optimization was carried out by the central composite design method. The central composite design optimization method resulted in 1.10 mL dispersive solvent, 138.46 mu L extraction solvent, and 4.46 mL sample volume. Under the optimal terms, the calibration curve was linear over the range of 0.003-0.18 and 0.007-0.18 mu g/mL in water and urine samples, respectively. The limit of detection and quantification of the proposed approach for 2-mercaptobenzimidazole were 0.013 and 0.044 mu g/mL in water samples and 0.016 and 0.052 mu g/mL in urine samples, respectively. The method was successfully applied to determination of 2-mercaptobenzimidazole in urine and water samples.
引用
收藏
页码:2467 / 2473
页数:7
相关论文
共 43 条
[1]   Analysis of thyreostatic drugs in thyroid samples by liquid chromatography tandem mass spectrometry: Comparison of two sample treatment strategies [J].
Abuin, S. ;
Companyo, R. ;
Centrich, F. ;
Rubies, A. ;
Prat, M. D. .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1207 (1-2) :17-23
[2]   Analysis of thyreostatic drugs in thyroid samples by Ultra-Performance Liquid Chromatography tandem mass spectrometry detection [J].
Abuinb, S. ;
Centrich, F. ;
Rubies, A. ;
Companyo, R. ;
Prat, M. D. .
ANALYTICA CHIMICA ACTA, 2008, 617 (1-2) :184-191
[3]   Separation/preconcentration and determination of quercetin in food samples by dispersive liquid-liquid microextraction based on solidification of floating organic drop -flow injection spectrophotometry [J].
Asadollahi, Tahereh ;
Dadfarnia, Shayessteh ;
Shabani, Ali Mohammad Haji ;
Amirkavei, Mooud .
JOURNAL OF FOOD SCIENCE AND TECHNOLOGY-MYSORE, 2015, 52 (02) :1103-1109
[4]   Determination of BTEX Compounds by Dispersive Liquid-Liquid Microextraction with GC-FID [J].
Assadi, Yaghoub ;
Ahmadi, Fardin ;
Hossieni, Mohammad Reza Milani .
CHROMATOGRAPHIA, 2010, 71 (11-12) :1137-1141
[5]   Mixed hemimicelles solid-phase extraction based on sodium dodecyl sulfate (SDS)-coated nano-magnets for the spectrophotometric determination of Fingolomid in biological fluids [J].
Azari, Zhila ;
Pourbasheer, Eslam ;
Beheshti, Abolghasem .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2016, 153 :599-604
[6]   Simultaneous Spectrophotometric Determination of 2-Thiouracil and 2-Mercaptobenzimidazole in Animal Tissue Using Multivariate Calibration Methods: Concerns and Rapid Methods for Detection [J].
Beheshti, Abolghasem ;
Riahi, Siavash ;
Pourbasheer, Eslam ;
Ganjali, Mohammad Reza ;
Norouzi, Parviz .
JOURNAL OF FOOD SCIENCE, 2010, 75 (02) :C135-C139
[7]   Response surface methodology (RSM) as a tool for optimization in analytical chemistry [J].
Bezerra, Marcos Almeida ;
Santelli, Ricardo Erthal ;
Oliveira, Eliane Padua ;
Villar, Leonardo Silveira ;
Escaleira, Luciane Amlia .
TALANTA, 2008, 76 (05) :965-977
[8]   Selenium analysis in water samples by dispersive liquid-liquid microextraction based on piazselenol formation and GC-ECD [J].
Bidari, Araz ;
Hemmatkhah, Payam ;
Jafarvand, Sanaz ;
Hosseini, Mohammad Reza Milani ;
Assadi, Yaghoub .
MICROCHIMICA ACTA, 2008, 163 (3-4) :243-249
[9]   Determination of mercaptobenzimidazol and other thyreostat residues in thyroid tissue and meat using high-performance liquid chromatography-mass spectrometry [J].
De Wasch, K ;
Brabander, HFB ;
Impens, S ;
Vandewiele, M ;
Courtheyn, D .
JOURNAL OF CHROMATOGRAPHY A, 2001, 912 (02) :311-317
[10]  
DEBRABANDER HF, 1992, JPC-J PLANAR CHROMAT, V5, P124