Interharmonic Differential Relay With a Soft Current Limiter for the Protection of Inverter-Based Islanded Microgrids
被引:22
作者:
El-Sayed, Wael T.
论文数: 0引用数: 0
h-index: 0
机构:
Khalifa Univ, EECS Dept, Adv Power & Energy Ctr, Abu Dhabi 31757, U Arab EmiratesKhalifa Univ, EECS Dept, Adv Power & Energy Ctr, Abu Dhabi 31757, U Arab Emirates
El-Sayed, Wael T.
[1
]
El-Saadany, Ehab F.
论文数: 0引用数: 0
h-index: 0
机构:
Khalifa Univ, EECS Dept, Adv Power & Energy Ctr, Abu Dhabi 31757, U Arab EmiratesKhalifa Univ, EECS Dept, Adv Power & Energy Ctr, Abu Dhabi 31757, U Arab Emirates
El-Saadany, Ehab F.
[1
]
Zeineldin, Hatem H.
论文数: 0引用数: 0
h-index: 0
机构:
Cairo Univ, Fac Engn, Giza 12624, EgyptKhalifa Univ, EECS Dept, Adv Power & Energy Ctr, Abu Dhabi 31757, U Arab Emirates
Zeineldin, Hatem H.
[2
]
机构:
[1] Khalifa Univ, EECS Dept, Adv Power & Energy Ctr, Abu Dhabi 31757, U Arab Emirates
Current limiters;
Fault currents;
Microgrids;
Resistance;
Bandwidth;
Protective relaying;
Microgrid;
inverter-interfaced distributed generator;
current limiter;
differential protection;
interharmonics;
FAULT-DETECTION;
SCHEME;
D O I:
10.1109/TPWRD.2020.3006791
中图分类号:
TM [电工技术];
TN [电子技术、通信技术];
学科分类号:
0808 ;
0809 ;
摘要:
Inverter-interfaced distributed generators (IIDGs) introduce a major challenge for the protection of inverter-based islanded microgrids (IBIMs) due to their limited fault current contribution. This paper proposes a new strategy for the protection of IBIMs, founded on two novel aspects including a soft current limiter and an interharmonic differential relay. In addition to limiting the fault current, the proposed current limiter performs an amplitude modulation of the output fault current from the IIDG which occurs only during fault conditions. This modulation produces interharmonic currents with specific signatures that flow towards the fault. The process of injecting interharmonics is spontaneously initiated by a subset of the IIDGs upon the fault occurrence without a need for a fault detection scheme. Thereafter, based on the locally detected interharmonics, an interharmonic differential relay requiring low bandwidth communication is proposed to identify and isolate the fault. The proposed strategy has been validated using PSCAD/EMTDC. The results confirm the ability of the proposed protection strategy to protect IBIMs considering different fault types, locations, and values of the fault resistance without the need for additional fault detection components or high-bandwidth communication which may constraint the applicability and reliability of the protection schemes.