Contact-cooled U-monochromators for high heat load x-ray beamlines

被引:0
|
作者
Khounsary, A
Yun, W
Trakhtenberg, E
Xu, S
Assoufid, L
Lee, WK
机构
关键词
monochromator; x-ray; thermal management; contact cooled;
D O I
10.1117/12.259880
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
This paper describes the design, expected performance, and preliminary test results of a contact-cooled monochromator for use on high heat load x-ray beamlines. The monochromator has a cross section in the shape of the letter U. This monochromator should be suitable for handing heat fluxes up to 5 W/mm(2). As such,for the present application, it is compatible with the best internally cooled silicon crystal monochromators operating at room temperature. There are three key features in the design of this monochromator. First, it is contact cooled, thereby eliminating fabrication of cooling channels, bonding, and undesirable strains in the monochromator due to coolant-manifold-to-crystal-interface. Second, by illuminating the entire length of the crystal and extracting the central part of the reflected beam, sharp slope changes in the beam profile and thus slope errors ate avoided. Last, by selecting appropriate crystal geometry and cooling locations, tangential slope error can be substantially reduced.
引用
收藏
页码:258 / 265
页数:8
相关论文
共 50 条
  • [41] Are X-ray clusters cooled by heat conduction to the surrounding intergalactic medium?
    Loeb, A
    NEW ASTRONOMY, 2002, 7 (06): : 279 - 282
  • [42] THERMAL-STRESS ANALYSIS AND DIFFRACTION SIMULATION OF A STANDARD AND INCLINED GALLIUM-COOLED HIGH-HEAT-LOAD X-RAY MONOCHROMATOR
    ROGERS, CS
    MACRANDER, AT
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 335 (03): : 561 - 568
  • [43] THE POTENTIAL OF CRYOGENIC SILICON AND GERMANIUM X-RAY MONOCHROMATORS FOR USE WITH LARGE SYNCHROTRON HEAT LOADS
    BILDERBACK, DH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3): : 434 - 436
  • [44] Water cooled first crystal as a solution for high-heat-load problem at the SPring-8 undulator beamlines
    Ishikawa, T
    Yamazaki, H
    Tamasaku, K
    Yabashi, M
    Kuroda, M
    Goto, S
    CRYSTAL AND MULTILAYER OPTICS, 1998, 3448 : 2 - 10
  • [45] Performances of synchrotron X-ray monochromators under heat load. Part 2. Application of the Takagi-Taupin diffraction theory
    Mocella, V
    Ferrero, C
    Freund, AK
    Hoszowska, J
    Zhang, L
    Epelboin, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 414 - 417
  • [46] Calculations and surface quality measurements of high-asymmetry angle x-ray crystal monochromators for advanced x-ray imaging and metrological applications
    Zaprazny, Zdenko
    Korytar, Dusan
    Jergel, Matej
    Siffalovic, Peter
    Dobrocka, Edmund
    Vagovic, Patrik
    Ferrari, Claudio
    Mikulik, Petr
    Demydenko, Maksym
    Mikloska, Marek
    OPTICAL ENGINEERING, 2015, 54 (03)
  • [47] A water-cooled high-voltage x-ray tube
    Coolidge, W. D.
    Moore, C. N.
    AMERICAN JOURNAL OF ROENTGENOLOGY AND RADIUM THERAPY, 1923, 10 : 884 - 890
  • [48] HIGH-PERFORMANCE, THERMOELECTRICALLY COOLED X-RAY AND GAMMA-RAY DETECTORS
    HUBER, AC
    PANTAZIS, JA
    JORDANOV, V
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1995, 99 (1-4): : 665 - 668
  • [49] A high-precision X-ray beam-position and profile monitor for synchrotron beamlines
    van Silfhout, RG
    JOURNAL OF SYNCHROTRON RADIATION, 1999, 6 : 1071 - 1075
  • [50] An initial evaluation of high quality synthetic diamond single crystals for synchrotron x-ray monochromators
    Freund, AK
    Hoszowska, J
    Sellschop, JPF
    Burns, R
    Rebak, M
    SYNCHROTRON RADIATION INSTRUMENTATION, 2000, 521 : 242 - 246