Contact-cooled U-monochromators for high heat load x-ray beamlines

被引:0
|
作者
Khounsary, A
Yun, W
Trakhtenberg, E
Xu, S
Assoufid, L
Lee, WK
机构
关键词
monochromator; x-ray; thermal management; contact cooled;
D O I
10.1117/12.259880
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
This paper describes the design, expected performance, and preliminary test results of a contact-cooled monochromator for use on high heat load x-ray beamlines. The monochromator has a cross section in the shape of the letter U. This monochromator should be suitable for handing heat fluxes up to 5 W/mm(2). As such,for the present application, it is compatible with the best internally cooled silicon crystal monochromators operating at room temperature. There are three key features in the design of this monochromator. First, it is contact cooled, thereby eliminating fabrication of cooling channels, bonding, and undesirable strains in the monochromator due to coolant-manifold-to-crystal-interface. Second, by illuminating the entire length of the crystal and extracting the central part of the reflected beam, sharp slope changes in the beam profile and thus slope errors ate avoided. Last, by selecting appropriate crystal geometry and cooling locations, tangential slope error can be substantially reduced.
引用
收藏
页码:258 / 265
页数:8
相关论文
共 50 条
  • [21] Liquid nitrogen cooled Si crystal monochromator: X-ray focusing by controlled heat load
    Zhang, L.
    del Rio, M. Sanchez
    Monaco, G.
    11TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI 2012), 2013, 425
  • [22] PRESERVING THE HIGH FINESSE OF X-RAY UNDULATOR BEAMS FROM PERFECT WATER-JET-COOLED DIAMOND MONOCHROMATORS
    BERMAN, LE
    HART, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 334 (2-3): : 617 - 620
  • [23] Monochromators for small cross-section x-ray beams for high heat flux synchrotron sources
    Ice, G
    Riemer, B
    Khounsary, A
    OPTICS FOR HIGH-BRIGHTNESS SYNCHROTRON RADIATION BEAMLINES II, 1996, 2856 : 226 - 235
  • [24] DESIGN AND THERMAL-STRESS ANALYSIS OF HIGH-POWER X-RAY MONOCHROMATORS COOLED WITH LIQUID-NITROGEN
    ROGERS, CS
    ASSOUFID, L
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02): : 2200 - 2202
  • [25] Water-cooled first crystals for the SPring-8 x-ray undulator beamlines
    Yamazaki, H
    Kimura, H
    Kagaya, I
    Yamashita, C
    Ishikawa, T
    X-RAY OPTICS DESIGN, PERFORMANCE, AND APPLICATIONS, 1999, 3773 : 21 - 29
  • [26] Diamond channel-cut crystals for high-heat-load beam-multiplexing narrow-band X-ray monochromators
    Shvyd'ko, Yuri
    Terentyev, Sergey
    Blank, Vladimir
    Kolodziej, Tomasz
    JOURNAL OF SYNCHROTRON RADIATION, 2021, 28 : 1720 - 1728
  • [27] PERFORMANCE ANALYSIS OF HIGH-POWER SYNCHROTRON X-RAY MONOCHROMATORS
    KHOUNSARY, AM
    CHRZAS, JJ
    MILLS, DM
    VICCARO, PJ
    OPTICAL ENGINEERING, 1990, 29 (10) : 1273 - 1280
  • [28] X-RAY MONOCHROMATORS FOR HIGH-POWER SYNCHROTRON RADIATION SOURCES
    HART, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 297 (1-2): : 306 - 311
  • [29] A thermal deformation optimization method for cryogenically cooled silicon crystal monochromators under high heat load
    Liu, Jiayin
    Ji, Zhan
    Fan, Yichen
    Yan, Xinxin
    Wang, Miaomiao
    Qin, Hongliang
    JOURNAL OF SYNCHROTRON RADIATION, 2024, 31 (Pt 2) : 260 - 267
  • [30] NOVEL ADAPTIVE DIRECTLY WATER-COOLED MONOCHROMATOR CRYSTAL FOR HIGH HEAT LOAD WIGGLER BEAMLINES
    SCHULTESCHREPPING, H
    MATERLIK, G
    HEUER, J
    TEICHMANN, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02): : 2217 - 2219