Contact-cooled U-monochromators for high heat load x-ray beamlines

被引:0
|
作者
Khounsary, A
Yun, W
Trakhtenberg, E
Xu, S
Assoufid, L
Lee, WK
机构
关键词
monochromator; x-ray; thermal management; contact cooled;
D O I
10.1117/12.259880
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
This paper describes the design, expected performance, and preliminary test results of a contact-cooled monochromator for use on high heat load x-ray beamlines. The monochromator has a cross section in the shape of the letter U. This monochromator should be suitable for handing heat fluxes up to 5 W/mm(2). As such,for the present application, it is compatible with the best internally cooled silicon crystal monochromators operating at room temperature. There are three key features in the design of this monochromator. First, it is contact cooled, thereby eliminating fabrication of cooling channels, bonding, and undesirable strains in the monochromator due to coolant-manifold-to-crystal-interface. Second, by illuminating the entire length of the crystal and extracting the central part of the reflected beam, sharp slope changes in the beam profile and thus slope errors ate avoided. Last, by selecting appropriate crystal geometry and cooling locations, tangential slope error can be substantially reduced.
引用
收藏
页码:258 / 265
页数:8
相关论文
共 50 条
  • [1] Contact-cooled U-monochromators for high heat load x-ray beamlines
    Khounsary, A
    Yun, W
    Trakhtenberg, E
    Xu, S
    Assoufid, L
    Lee, WK
    HIGH HEAT FLUX ENGINEERING III, 1996, 2855 : 232 - 239
  • [2] Experimental results with cryogenically cooled, thin, silicon crystal x-ray monochromators on high-heat-flux beamlines
    Rogers, CS
    Mills, DM
    Lee, WK
    Fernandez, PB
    Graber, T
    HIGH HEAT FLUX ENGINEERING III, 1996, 2855 : 170 - 179
  • [3] Performance of an optimally contact-cooled high-heat-load mirror at the APS
    Khounsary, A
    Yun, W
    McNulty, I
    Cai, Z
    Lai, B
    ADVANCES IN MIRROR TECHNOLOGY FOR SYNCHROTRON X-RAY AND LASER APPLICATIONS, 1998, 3447 : 81 - 91
  • [4] Limitations of Liquid Nitrogen Cooling of High Heat Load X-Ray Monochromators
    Khounsary, Ali
    Strons, Philip
    Kujala, Naresh
    Macrander, Albert
    ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS VII, 2012, 8502
  • [5] Thermal management of next-generation contact-cooled synchrotron x-ray mirrors
    Khounsary, A
    X-RAY OPTICS DESIGN, PERFORMANCE, AND APPLICATIONS, 1999, 3773 : 78 - 87
  • [6] UNDULATOR HEAT LOADING STUDIES ON X-RAY MONOCHROMATORS COOLED WITH LIQUID GALLIUM
    BILDERBACK, DH
    HENDERSON, C
    WHITE, J
    SMITHER, RK
    FORSTER, GA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 1973 - 1976
  • [7] High heat flux x-ray monochromators: What are the limits?
    Rogers, CS
    HIGH HEAT FLUX AND SYNCHROTRON RADIATION BEAMLINES, 1997, 3151 : 201 - 207
  • [8] Bonding techniques for the fabrication of internally cooled X-ray monochromators
    Smolenski, KW
    Conolly, C
    Doing, P
    Kiang, B
    Shen, Q
    HIGH HEAT FLUX ENGINEERING III, 1996, 2855 : 220 - 231
  • [9] WATER COOLED SILICON-CRYSTALS FOR X-RAY MONOCHROMATORS
    WAHL, R
    SHAH, R
    JACKSON, K
    TONNESSEN, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 318 (1-3): : 908 - 913
  • [10] Bonding techniques for the fabrication of internally cooled X-ray monochromators
    Smolenski, KW
    Conolly, C
    Doing, P
    Kiang, B
    Shen, Q
    OPTICS FOR HIGH-BRIGHTNESS SYNCHROTRON RADIATION BEAMLINES II, 1996, 2856 : 246 - 257