Voltammetric Determination of 5-Hydroxyindoleacetic Acid at Poly (p-amino benzene sulfonic acid) Modified Sensor

被引:0
|
作者
Yilmaz, Abidin [1 ]
Savan, Ebru Kuyumcu [2 ]
Erdogdu, Gamze [1 ]
机构
[1] Inonu Univ, Fac Sci, Dept Chem, TR-44280 Malatya, Turkey
[2] Inonu Univ, Fac Pharm, Dept Basic Pharmaceut Sci, Div Analyt Chem, TR-44280 Malatya, Turkey
来源
ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY | 2022年 / 14卷 / 04期
关键词
5-Hydroxyindolacetic acid; Serotonin; p-Amino benzene sulfonic acid; Differential pulse voltammetry; Cyclic voltammetry; GLASSY-CARBON ELECTRODE; PERFORMANCE LIQUID-CHROMATOGRAPHY; ASCORBIC-ACID; ELECTROCHEMICAL DETECTION; CEREBROSPINAL-FLUID; ACETIC-ACID; 5-HYDROXYTRYPTAMINE; NEUROTRANSMITTERS; METABOLITES; SEROTONIN;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In this study, the quantitative amount of 5-hydroxyindoleacetic acid (5-HIAA) was determined at poly (p-amino benzene sulfonic acid) (p-ABSA) modified glassy carbon electrode. The redox property of 5-HIAA was investigated by cyclic voltammetry. The cyclic voltammograms showed that the redox reaction of 5-HIAA was irreversible. Scan rate study showed that the redox reaction of 5-HIAA was controlled by both diffusion and adsorption on the poly (p-ABSA) modified sensor. Differential pulse voltammetry technique was used for the quantitative analysis of 5-HIAA in phosphate buffer solution at pH 7.00. The linear working range of the calibration graphs was determined as 1x10(-5)-9x10(-5) M (R-2, 0.9912), and the detection limit was determined as 5.3x10(-7) M. Recovery values in the analysis of urine samples were between 99.4% and 103.0%. The results showed that the modified sensor can be applied to the determination of 5-HIAA in the presence of ascorbic acid. The proposed sensor is promising for routine analysis due to its high selectivity, reproducibility, long-term stability, and high recovery values in biological samples.
引用
收藏
页码:418 / 431
页数:14
相关论文
共 50 条
  • [1] Graphene Nanoribbons/Poly-Bromocresol Green Based Sensor for the Simultaneous Determination of 3,4-Dihydroxyphenylacetic Acid and 5-Hydroxyindoleacetic Acid
    Raj, Mamta
    Goyal, Rajendra N.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (13) : B695 - B703
  • [2] Spectrofluorimetric determination of serotonin and 5-hydroxyindoleacetic acid in urine with different cyclodextrin media
    Guillermo Bracamonte, A.
    Veglia, Alicia V.
    TALANTA, 2011, 83 (03) : 1006 - 1013
  • [3] Investigation of the Voltammetric Behavior of Methyldopa at a Poly (p-Aminobenzene Sulfonic Acid) Modified Sensor
    Erdogdu, Gamze
    Yagci, Sevket Zisan
    Kuyumcu Savan, Ebru
    TURKISH JOURNAL OF PHARMACEUTICAL SCIENCES, 2019, 16 (04) : 450 - 456
  • [4] Voltammetric Determination of UricAcid on Poly(p-Aminobenzene Sulfonic Acid)-Modified Glassy Carbon Electrode
    Sadikoglu, Murat
    Taskin, Gamze
    Demirtas, Fatma Gul
    Selvi, Bedrettin
    Barut, Mustafa
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (11): : 11550 - 11557
  • [5] Poly(para amino benzene sulfonic acid) Modified Glassy Carbon Electrode for the Simultaneous as well as Individual Voltammetric Determination of Guanine, Adenine and Uric Acid
    Jesny, S.
    Kumar, K. Girish
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2018, 165 (14) : B720 - B726
  • [6] Simultaneous analysis of dopamine and 5-hydroxyindoleacetic acid at nanogold modified screen printed carbon electrodes
    Gupta, Pankaj
    Goyal, Rajendra N.
    Shim, Yoon-Bo
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 213 : 72 - 81
  • [7] Thioglycolic acid capped cadmium sulphide quantum dots as a turn-on fluorescence sensor for the determination of 5-hydroxyindoleacetic acid
    Swathy, S.
    Anand, Sanu K.
    Mathew, Manna Rachel
    Kumar, K. Girish
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2021, 409 (409)
  • [8] Voltammetric Determination of Nicotine at Poly(4-Amino-3-Hydroxynaphthalene Sulfonic Acid)-Modified Glassy Carbon Electrode
    Geto, Alemnew
    Amare, Maereg
    Tessema, Merid
    Admassie, Shimelis
    ELECTROANALYSIS, 2012, 24 (03) : 659 - 665
  • [9] Determination of vanillylmandelic, 5-hydroxyindoleacetic and homovanillic acid in urine by isocratic liquid chromatography
    Bonfigli, AR
    Coppa, G
    Testa, R
    Testa, I
    DeSio, G
    EUROPEAN JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1997, 35 (01): : 57 - 61
  • [10] Voltammetric Sensing of Uric Acid and Ascorbic Acid with Poly (p-toluene sulfonic acid) Modified Electrode
    Wang, Liang
    Huang, Pengfei
    Bai, Junyue
    Wang, Hongjing
    Wu, Xiaowei
    Zhao, Yuqing
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2006, 1 (06): : 334 - 342