Simultaneous voltammetric detection of ammonium and nitrite from groundwater at silver-electrodecorated carbon nanotube electrode

被引:43
作者
Baciu, Anamaria [1 ]
Manea, Florica [1 ]
Pop, Aniela [1 ]
Pode, Rodica [1 ]
Schoonman, Loop [2 ]
机构
[1] Politehn Univ Timisoara, Pta Victoriei 2, Timisoara 300006, Romania
[2] Delft Univ Technol, Dept Chem Engn, Mat Energy Convers & Storage, Julianalaan 136, NL-2626 BL Delft, Netherlands
关键词
Ammonium; Nitrite; Simultaneous voltammetric detection; Silver-electrodecorated carbon nanotubes-epoxy composite electrode; Electrochemical techniques; Groundwater; INJECTION SPECTROPHOTOMETRIC DETERMINATION; ELECTROCHEMICAL DETERMINATION; COMPOSITE ELECTRODES; NITRATE; WATER; NITROGEN; SAMPLES;
D O I
10.1016/j.psep.2016.05.006
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Ammonium and nitrite are listed by Water Framework Directive as core parameters that should be monitored for the groundwater as drinking water source. This work describes the sensitive protocols for the simultaneous detection of ammonium and nitrite in water at a new silver-electrodecorated carbon nanotubes-epoxy composite electrode (Ag-CNT) using advanced voltammetric technique. A carbon nanotubes-epoxy composite electrode obtained by two -roll mill procedure was decorated electrochemically with silver nanopartides. This new electrode displays excellent electrocatalytic activity towards the direct oxidation of ammonium and nitrite at well separated less potential values (+0.15 V/SCE for ammonium and +0.7 V/SCE for nitrite). Very good detection sensitivities (0.613 mA mM(-1) for ammonium and 0.980 mAmM(-1) for nitrite) and the lowest limits of detection (1 p.,M for ammonium and 0.7 p,M for nitrite) were achieved by differential -pulsed voltammetry (DPV) under optimum operating conditions of 0.05 V step potential, 0.2 V modulation amplitude and the scan rate of 0.05 Vs(-1). This detection protocol was successfully applied to the simultaneous determination of ammonium and nitrite in groundwater samples, and the results were found to be consistent with the values obtained by the standardized spectrophotometry methods. (C) 2016 Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:18 / 25
页数:8
相关论文
共 39 条
[1]   Simultaneous Voltammetric/Amperometric Determination of Sulfide and Nitrite in Water at BDD Electrode [J].
Baciu, Anamaria ;
Ardelean, Magdalena ;
Pop, Aniela ;
Pode, Rodica ;
Manea, Florica .
SENSORS, 2015, 15 (06) :14526-14538
[2]  
Baciu A, 2010, ENVIRON ENG MANAG J, V9, P1555
[3]   New electrochemical sensors for detection of nitrites and nitrates [J].
Badea, M ;
Amine, A ;
Palleschi, G ;
Moscone, D ;
Volpe, G ;
Curulli, A .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 509 (01) :66-72
[4]   Ammonium transport and reaction in contaminated groundwater:: Application of isotope tracers and isotope fractionation studies [J].
Böhlke, JK ;
Smith, RL ;
Miller, DN .
WATER RESOURCES RESEARCH, 2006, 42 (05)
[5]  
Chou SS, 2003, J FOOD DRUG ANAL, V11, P233
[6]  
da Silva SM, 1998, ELECTROANAL, V10, P1200, DOI 10.1002/(SICI)1521-4109(199811)10:17<1200::AID-ELAN1200>3.0.CO
[7]  
2-5
[8]   Electrochemical detection of nitrate and nitrite at a copper modified electrode [J].
Davis, J ;
Moorcroft, MJ ;
Wilkins, SJ ;
Compton, RG ;
Cardosi, MF .
ANALYST, 2000, 125 (04) :737-741
[9]   Cyclic voltammetric studies of nitrate and nitrite ion reduction at the surface of iridium-modified carbon fiber electrode [J].
De, D ;
Englehardt, JD ;
Kalu, EE .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2000, 147 (11) :4224-4228
[10]   Current strategies in nitrite detection and their application to field analysis [J].
Dutt, J ;
Davis, J .
JOURNAL OF ENVIRONMENTAL MONITORING, 2002, 4 (03) :465-471