A low-cost integrated biosensing platform based on SiN nanophotonics for biomarker detection in urine

被引:41
作者
Martens, D. [1 ,2 ]
Ramirez-Priego, P. [3 ]
Murib, M. S. [1 ,2 ]
Elamin, A. A. [4 ]
Gonzalez-Guerrero, A. B. [3 ]
Stehr, M. [4 ]
Jonas, F. [4 ]
Anton, B. [5 ]
Hlawatsch, N. [5 ]
Soetaert, P. [6 ]
Vos, R. [7 ]
Stassen, A. [7 ]
Severi, S. [7 ]
Van Roy, W. [7 ]
Bockstaele, R. [6 ]
Becker, H. [5 ]
Singh, M. [4 ]
Lechuga, L. M. [3 ]
Bienstman, P. [1 ,2 ]
机构
[1] Univ Ghent, Photon Res Grp, IMEC, Technol Pk Zwijnaarde 15, B-9052 Ghent, Belgium
[2] Univ Ghent, Ctr Nano & Biophoton NB Photon, Ghent, Belgium
[3] CSIC, ICN2, Nanobiosensors & Bioanalyt Applicat Grp, BIST,CIBER BBN, Campus UAB, Barcelona 08193, Spain
[4] LIONEX Diagnost & Therapeut GmbH, Braunschweig, Germany
[5] Microfluid ChipShop GmbH, D-07747 Jena, Germany
[6] Trinean NV, Dulle Grietlaan 17-3, B-9050 Ghent, Belgium
[7] 7 Imec, Kapeldreef 75, B-3001 Leuven, Belgium
关键词
PROTEIN;
D O I
10.1039/c8ay00666k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We present a low-cost integrated nanophotonic lab-on-a-chip platform suitable for point-of-care (POC) biomarker analysis. The sensor chip included in the platform contains multiplexed Mach-Zehnder interferometers with an on-chip optical spectral analyser consisting of an arrayed-waveguide grating. The sensor chip is fabricated in silicon nitride material, which makes it compatible with consumer-electronics-grade sources and detectors, leading to the possibility of low-cost instrumentation. The nanophotonic sensor chip exhibits a detection limit of 6 x 10(-6) RIU (Refractive Index Units), which is in the same order of magnitude as the reported values for state-of-the-art evanescent wave sensors. The sensor chip is biofunctionalised with specific bioreceptors and integrated into a polymer microfluidic cartridge. The POC instrumentation platform contains optical excitation and read-out sub-systems and dedicated on-board software for real-time analysis of patient samples. To demonstrate the versatility of the platform, we present results both on the detection of an antigen related to tuberculosis directly in urine samples using a laboratory prototype and on the detection of a protein biomarker (CRP) related to inflammation using the integrated instrument.
引用
收藏
页码:3066 / 3073
页数:8
相关论文
共 18 条
  • [1] Vernier-cascade label-free biosensor with integrated arrayed waveguide grating for wavelength interrogation with low-cost broadband source
    Claes, Tom
    Bogaerts, Wim
    Bienstman, Peter
    [J]. OPTICS LETTERS, 2011, 36 (17) : 3320 - 3322
  • [2] Rapid Urine LAM Testing Improves Diagnosis of Expectorated Smear-Negative Pulmonary Tuberculosis in an HIV-endemic Region
    Drain, Paul K.
    Gounder, Lilishia
    Sahid, Faieza
    Moosa, Mahomed-Yunus S.
    [J]. SCIENTIFIC REPORTS, 2016, 6
  • [3] Sensitive optical biosensors for unlabeled targets: A review
    Fan, Xudong
    White, Ian M.
    Shopova, Siyka I.
    Zhu, Hongying
    Suter, Jonathan D.
    Sun, Yuze
    [J]. ANALYTICA CHIMICA ACTA, 2008, 620 (1-2) : 8 - 26
  • [4] Last Advances in Silicon-Based Optical Biosensors
    Fernandez Gavela, Adrian
    Grajales Garcia, Daniel
    Ramirez, Jhonattan C.
    Lechuga, Laura M.
    [J]. SENSORS, 2016, 16 (03)
  • [5] Trends in photonic lab-on-chip interferometric biosensors for point-of-care diagnostics
    Gonzalez-Guerrero, A. B.
    Maldonado, J.
    Herranz, S.
    Lechuga, L. M.
    [J]. ANALYTICAL METHODS, 2016, 8 (48) : 8380 - 8394
  • [6] Integrated optical frequency-resolved Mach-Zehnder interferometers for label-free affinity sensing
    Kitsara, Maria
    Misiakos, Konstantinos
    Raptis, Ioannis
    Makarona, Eleni
    [J]. OPTICS EXPRESS, 2010, 18 (08): : 8193 - 8206
  • [7] Klotz IM., 1967, METH ENZYMOL, V11, P576
  • [8] Optical integrated chips with micro and nanostructures for refractive index and SERS-based optical label-free sensing
    Liu, Liu
    Jin, Mingliang
    Shi, Yaocheng
    Lin, Jiao
    Zhang, Yuan
    Jiang, Li
    Zhou, Guofu
    He, Sailing
    [J]. NANOPHOTONICS, 2015, 4 (04) : 419 - 436
  • [9] Comparison between Vernier-cascade and MZI as transducer for biosensing with on-chip spectral filter
    Martens, Daan
    Bienstman, Peter
    [J]. NANOPHOTONICS, 2017, 6 (04) : 703 - 712
  • [10] Optimized Si3N4 grating couplers for relaxed alignment requirements under flood illumination
    Martens, Daan
    Dong, Genghua
    Bienstman, Peter
    [J]. APPLIED OPTICS, 2017, 56 (05) : 1286 - 1290