Long-Term Evaluation of the Controlled Pressure Method for Assessment of the Vapor Intrusion Pathway

被引:30
作者
Holton, Chase [1 ]
Guo, Yuanming [1 ]
Luo, Hong [1 ,2 ]
Dahlen, Paul [1 ]
Gorder, Kyle [3 ]
Dettenmaier, Erik [3 ]
Johnson, Paul C. [1 ]
机构
[1] Arizona State Univ, Sch Sustainable Engn & Built Environm, Ira A Fulton Sch Engn, Tempe, AZ 85287 USA
[2] Chevron Energy Technol Co, Houston, TX 77042 USA
[3] Hill AFB, Restorat Installat Support Team, Hill AFB, UT 84056 USA
关键词
VARIABILITY; TRANSPORT; HOUSE; SOIL;
D O I
10.1021/es5052342
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Vapor intrusion (VI) investigations often require sampling of indoor air for evaluating occupant risks, but can be confounded by temporal variability and the presence of indoor sources. Controlled pressure methods (CPM) have been proposed as an alternative, but temporal variability of CPM results and whether they are indicative of impacts under natural conditions have not been rigorously investigated. This study is the first involving a long-term CPM test at a house having a multiyear high temporal resolution indoor air data set under natural conditions. Key observations include (a) CPM results exhibited low temporal variability, (b) false-negative results were not obtained, (c) the indoor air concentrations were similar to the maximum concentrations under natural conditions, and (d) results exceeded long-term average concentrations and emission rates under natural conditions by 1-2 orders of magnitude. Thus, the CPM results were a reliable indicator of VI occurrence and worst-case exposure regardless of day or time of year of the CPM test.
引用
收藏
页码:2091 / 2098
页数:8
相关论文
共 18 条
[1]  
American Petroleum Institute, 2005, PRACT STRAT ASS SUBS
[2]  
[Anonymous], 2012, FLUCT IND RAD VOC CO
[3]   On-Site Gas Chromatography/Mass Spectrometry (GC/MS) Analysis to Streamline Vapor Intrusion Investigations [J].
Beckley, Lila ;
Gorder, Kyle ;
Dettenmaier, Erik ;
Rivera-Duarte, Ignacio ;
McHugh, Thomas .
ENVIRONMENTAL FORENSICS, 2014, 15 (03) :234-243
[4]  
California Department of Toxic Substances Control, 2011, GUID EV MIT SUBS VAP
[5]  
Department of Defense, 2009, VAP INTR HDB
[6]  
DiGuilio D. C., 2006, ASSESSMENT VAPOR INT
[7]   Observed Spatial and Temporal Distributions of CVOCs at Colorado and New York Vapor Intrusion Sites [J].
Folkes, David ;
Wertz, William ;
Kurtz, Jeffrey ;
Kuehster, Theodore .
GROUND WATER MONITORING AND REMEDIATION, 2009, 29 (01) :70-80
[8]   Portable GC/MS Methods to Evaluate Sources of cVOC Contamination in Indoor Air [J].
Gorder, Kyle A. ;
Dettenmaier, Erik M. .
GROUND WATER MONITORING AND REMEDIATION, 2011, 31 (04) :113-119
[9]   Temporal Variability of Indoor Air Concentrations under Natural Conditions in a House Overlying a Dilute Chlorinated Solvent Groundwater Plume [J].
Holton, Chase ;
Luo, Hong ;
Dahlen, Paul ;
Gorder, Kyle ;
Dettenmaier, Erik ;
Johnson, Paul C. .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2013, 47 (23) :13347-13354
[10]  
ITRC, 2007, Vapor Intrusion Pathway: A Practical Guideline