Development of a rapid and sensitive method for determination of cysteine/cystine ratio in chemically defined media

被引:24
作者
Alwael, Hassan [1 ]
Connolly, Damian
Barron, Leon
Paull, Brett [1 ]
机构
[1] Dublin City Univ, Natl Ctr Sensor Res, Ctr Bioanalyt Sci, Dublin 9, Ireland
关键词
Cysteine; Cystine; Chemically defined media; Monolithic RPLC; LC-ESI-MS; PERFORMANCE LIQUID-CHROMATOGRAPHY; MOLECULAR-MASS THIOLS; HUMAN PLASMA; CAPILLARY-ELECTROPHORESIS; FLUORESCENCE DETECTION; TOTAL HOMOCYSTEINE; ULTRAVIOLET DETECTION; HUMAN URINE; DERIVATIZATION; CYSTEINYLGLYCINE;
D O I
10.1016/j.chroma.2010.04.036
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Two rapid, sensitive and quantitative methods for the determination of the cysteine and cystine ratio in complex defined media feedstock using monolithic reversed-phase liquid chromatography (RPLC) and RPLC-MS are presented. Cysteine is pre-derivatised with purified 2-chloro-1-methylquinolinium tetrafluoroborate (CMQT) and separated from other derivatisation products on a narrow-bore 50 mm x 2 mm I.D. monolithic C-18 column with UV detection at 355 nm. For reversed-phase LC (RPLC) the separation is carried out isocratically using a mobile phase of 50 mM trichloroacetic acid (TCA) adjusted to pH 2.5 with lithium hydroxide (LiOH) and acetonitrile (83:14) pumped at 1.5 mL/min with an elevated column temperature. For RPLC-MS an ammonium acetate and acetonitrile gradient method was developed with a reduced flow rate of 0.3 mL/min. The treatment of the samples consisted of dividing them into two aliquots, the first aliquot is analysed for cysteine and the second aliquot is analysed for cystine after its quantitative reduction to cysteine using tris(2-carboxyethyl)phosphine (TCEP). Both methods are linear, with R-2 > 0.999 for 0.25-500 mu M for cysteine and 0.25-250 mu M for cystine using the LC-UV method, sensitive, with detection limit of 36 nM for cysteine, and precise, with <= 1.1% RSD for both retention time and peak area (n = 6). Samples (n = 31) of an industry standard and supplied chemically defined media feedstock were analysed, finding cysteine ranging from 1.56 to 2.26 mu g/mL and cystine from 1062.02 to 1348.13 mu g/mL (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:3863 / 3870
页数:8
相关论文
共 22 条
[1]   Analysis of plasma thiols by high-performance liquid chromatography with ultraviolet detection [J].
Bald, E ;
Chwatko, G ;
Glowacki, R ;
Kusmierek, K .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1032 (1-2) :109-115
[2]   2-Chloro-1-methylquinolinium tetrafluoroborate as an effective and thiol specific uv-tagging reagent for liquid chromatography [J].
Bald, E ;
Glowacki, R .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2001, 24 (09) :1323-1339
[3]   Liquid chromatographic assessment of total and protein-bound homocysteine in human plasma [J].
Bald, E ;
Kaniowska, E ;
Chwatko, G ;
Glowacki, R .
TALANTA, 2000, 50 (06) :1233-1243
[4]   Simultaneous determination of cysteine, cystine and 18 other amino acids in various matrices by high-performance liquid chromatography [J].
Campanella, L ;
Crescentini, G ;
Avino, P .
JOURNAL OF CHROMATOGRAPHY A, 1999, 833 (02) :137-145
[5]   Determination of different species of homocysteine in human plasma by high-performance liquid chromatography with ultraviolet detection [J].
Chwatko, G ;
Bald, E .
JOURNAL OF CHROMATOGRAPHY A, 2002, 949 (1-2) :141-151
[6]   Determination of biologically active low-molecular-mass thiols in human blood III. Highly sensitive narrow-bore isocratic reversed-phase highperformance liquid chromatography with fluorescence detection [J].
Ivanov, AR ;
Nazimov, IV ;
Baratova, L ;
Lobazov, AP ;
Popovich, GB .
JOURNAL OF CHROMATOGRAPHY A, 2001, 913 (1-2) :315-318
[7]   Determination of biologically active low-molecular-mass thiols in human blood II. High-performance capillary electrophoresis with photometric detection [J].
Ivanov, AR ;
Nazimov, IV ;
Baratova, LA .
JOURNAL OF CHROMATOGRAPHY A, 2000, 895 (1-2) :167-171
[8]   Determination of biologically active low-molecular-mass thiols in human blood I. Fast qualitative and quantitative, gradient and isocratic reversed-phase high-performance liquid chromatography with photometric and fluorescence detection [J].
Ivanov, AR ;
Nazimov, IV ;
Baratova, L .
JOURNAL OF CHROMATOGRAPHY A, 2000, 895 (1-2) :157-166
[9]  
Kang SH, 1997, J PHARMACEUT BIOMED, V15, P1435, DOI 10.1016/S0731-7085(96)02051-1
[10]   Chiral separation of homocysteine by derivatization with 4-aminosulfonyl-7-fluoro-2,1,3-benzoxadiazole followed by capillary electrophoresis using γ-cyclodextrin [J].
Kim, IJ ;
Park, SJ ;
Kim, HJ .
JOURNAL OF CHROMATOGRAPHY A, 2000, 877 (1-2) :217-223