A rapid and fully-automated method for the quantitation of tricyclic antidepressants in serum using turbulent-flow liquid chromatography-tandem mass spectrometry

被引:43
作者
Breaud, Autumn R. [1 ]
Harlan, Robert [1 ]
Di Bussolo, Joseph M. [2 ]
McMillin, Gwendolyn A. [3 ]
Clarke, William [1 ]
机构
[1] Johns Hopkins Sch Med, Dept Pathol, Baltimore, MD USA
[2] Thermo Fisher Sci, Franklin, MA USA
[3] Univ Utah, Hlth Sci Ctr, ARUP Labs, Salt Lake City, UT USA
关键词
Antidepressants; Turbulent-flow liquid chromatography-mass spectrometry; HUMAN-PLASMA; SAMPLE PREPARATION; SIMULTANEOUS QUANTIFICATION; ELECTROSPRAY-IONIZATION; GAS-CHROMATOGRAPHY; ISOTOPE-DILUTION; DRUGS; HPLC; NORTRIPTYLINE; EXTRACTION;
D O I
10.1016/j.cca.2010.02.067
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: We describe a fully-automated turbulent-flow liquid chromatography-tandem mass spectrometry method for the detection of tricyclic antidepressant drugs (amitriptyline, desipramine, imipramine, and nortriptyline) in serum. Methods: Human serum and an internal standard were injected directly onto a Cyclone-P online solid-phase extraction (SPE) column (0.5 x 50 mm). Following removal of serum proteins and other components the analytes were transferred to a Hypersil Gold C-18 (50 x 3 mm) analytical column. Elution occurred with a gradient of water and acetonitrile each with 0.1% formic acid. Analytes were ionized and detected over a 3.5 min analysis time by electrospray-ionization mass spectrometry with selected reaction monitoring (SRM). Matrix effects were well-characterized and carryover, precision, linearity, recovery and limits of detection and quantitation were evaluated. Results: The simple and complex precision CVs for all compounds were <= 16%. The limits of detection and quantitation for all drugs were <= 3 ng/ml and <20 ng/ml, respectively. Recoveries were between 97 and 114%. Slopes for method comparison plots were all >0.96. Proficiency testing materials had values within 2 SDI of peer group means for all drugs. Conclusion: Based on validation data, this is a specific, sensitive fully-automated method for rapid quantitation of tricyclic antidepressants in serum. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:825 / 832
页数:8
相关论文
共 41 条
[1]   Analysis of tricyclic antidepressant drugs in plasma by means of solid-phase microextraction-liquid chromatography-mass spectrometry [J].
Alves, Claudete ;
Santos-Neto, Alvaro J. ;
Fernandes, Christian ;
Rodrigues, Jose C. ;
Lancas, Fernando M. .
JOURNAL OF MASS SPECTROMETRY, 2007, 42 (10) :1342-1347
[2]  
[Anonymous], 2004, CLSI Document EP5-A2
[3]  
[Anonymous], 2004, EP17A NCCLS
[4]   Sensitive and rapid method for the simultaneous quantification of five antidepressants with their respective metabolites in plasma using high-performance liquid chromatography with diode-array detection [J].
Aymard, G ;
Livi, P ;
Pham, YT ;
Diquet, B .
JOURNAL OF CHROMATOGRAPHY B, 1997, 700 (1-2) :183-189
[5]  
Ayrton J, 1997, RAPID COMMUN MASS SP, V11, P1953, DOI 10.1002/(SICI)1097-0231(199712)11:18<1953::AID-RCM102>3.0.CO
[6]  
2-Z
[7]  
Bonfiglio R, 1999, RAPID COMMUN MASS SP, V13, P1175, DOI 10.1002/(SICI)1097-0231(19990630)13:12<1175::AID-RCM639>3.0.CO
[8]  
2-0
[9]  
Bose Devasish, 2005, Journal of Pharmacological and Toxicological Methods, V52, P323, DOI 10.1016/j.vascn.2005.04.015
[10]   A rapid and reliable method for the quantitation of tricyclic antidepressants in serum using HPLC-MS/MS [J].
Breaud, Autumn R. ;
Harlan, Robert ;
Kozak, Marta ;
Clarke, William .
CLINICAL BIOCHEMISTRY, 2009, 42 (12) :1300-1307