Focused intravascular ultrasonic probe using dimpled transducer elements

被引:13
作者
Chen, Y. [1 ,2 ]
Qiu, W. B. [3 ]
Lam, K. H. [4 ]
Liu, B. Q. [3 ]
Jiang, X. P. [5 ]
Zheng, H. R. [3 ]
Luo, H. S. [6 ]
Chan, H. L. W. [1 ,2 ]
Dai, J. Y. [1 ,2 ]
机构
[1] Hong Kong Polytech Univ, Shenzhen Res Inst, Shenzhen, Peoples R China
[2] Hong Kong Polytech Univ, Dept Appl Phys, Hong Kong, Hong Kong, Peoples R China
[3] Chinese Acad Sci, Paul C Lauterbur Res Ctr Biomed Imaging, Shenzhen Inst Adv Technol, Inst Biomed & Hlth, Shenzhen, Peoples R China
[4] Hong Kong Polytech Univ, Dept Elect Engn, Hong Kong, Hong Kong, Peoples R China
[5] Jingdezhen Ceram Inst, Dept Mat Sci & Engn, Jingdezhen, Peoples R China
[6] Chinese Acad Sci, Shanghai Inst Ceram, Informat Mat & Devices Res Ctr, Shanghai 200050, Peoples R China
基金
美国国家科学基金会;
关键词
Intravascular ultrasound; Dimple technique; PMN-PT single crystal; Lead-free ceramic;
D O I
10.1016/j.ultras.2014.07.011
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
High-frequency focused intravascular ultrasonic probes were fabricated in this study using dimple technique based on PMN-PT single crystal and lead-free KNN-KBT-Mn ceramic. The center frequency, bandwidth, and insertion loss of the PMN-PT transducer were 34 MHz, 75%, and 22.9 dB, respectively. For the lead-free probe, the center frequency, bandwidth, and insertion loss were found to be 40 MHz, 72%, and 28.8 dB, respectively. The ultrasonic images of wire phantom and vessels with good resolution were obtained to evaluate the transducer performance. The -6 dB axial and lateral resolutions of the PMN-PT probe were determined to be 58 mu m and 131 mu m, respectively. For the lead-free probe, the axial and lateral resolutions were found to be 44 mu m and 125 mu m, respectively. These results suggest that the mechanical dimpling technique has good potential in preparing focused transducers for intravascular ultrasound applications. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:227 / 231
页数:5
相关论文
共 22 条
[1]  
[Anonymous], 1982, J. Ultrasound Med.
[2]   Intravascular Optical-Resolution Photoacoustic Tomography with a 1.1 mm Diameter Catheter [J].
Bai, Xiaosong ;
Gong, Xiaojing ;
Hau, William ;
Lin, Riqiang ;
Zheng, Jiaxiang ;
Liu, Chengbo ;
Zeng, Chengzhi ;
Zou, Xin ;
Zheng, Hairong ;
Song, Liang .
PLOS ONE, 2014, 9 (03)
[3]   Design considerations for piezoelectric polymer ultrasound transducers [J].
Brown, LF .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2000, 47 (06) :1377-1396
[4]   High frequency PMN-PT single crystal focusing transducer fabricated by a mechanical dimpling technique [J].
Chen, Y. ;
Lam, K. H. ;
Zhou, D. ;
Cheng, W. F. ;
Dai, J. Y. ;
Luo, H. S. ;
Chan, H. L. W. .
ULTRASONICS, 2013, 53 (02) :345-349
[5]   High-Frequency Ultrasonic Transducer Fabricated With Lead-Free Piezoelectric Single Crystal [J].
Chen, Yan ;
Jiang, Xiang Ping ;
Luo, Hao Su ;
Dai, Ji Yan ;
Chan, Helen L. W. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2010, 57 (11) :2601-2604
[6]   QUANTITATIVE CORONARY ANGIOGRAPHY TO MEASURE PROGRESSION AND REGRESSION OF CORONARY ATHEROSCLEROSIS - VALUE, LIMITATIONS, AND IMPLICATIONS FOR CLINICAL-TRIALS [J].
DEFEYTER, PJ ;
SERRUYS, PW ;
DAVIES, MJ ;
RICHARDSON, P ;
LUBSEN, J ;
OLIVER, MF .
CIRCULATION, 1991, 84 (01) :412-423
[7]   Advances in ultrasound biomicroscopy [J].
Foster, FS ;
Pavlin, CJ ;
Harasiewicz, KA ;
Christopher, DA ;
Turnbull, DH .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (01) :1-27
[8]   Heart Disease and Stroke Statistics-2013 Update A Report From the American Heart Association [J].
Go, Alan S. ;
Mozaffarian, Dariush ;
Roger, Veronique L. ;
Benjamin, Emelia J. ;
Berry, Jarett D. ;
Borden, William B. ;
Bravata, Dawn M. ;
Dai, Shifan ;
Ford, Earl S. ;
Fox, Caroline S. ;
Franco, Sheila ;
Fullerton, Heather J. ;
Gillespie, Cathleen ;
Hailpern, Susan M. ;
Heit, John A. ;
Howard, Virginia J. ;
Huffman, Mark D. ;
Kissela, Brett M. ;
Kittner, Steven J. ;
Lackland, Daniel T. ;
Lichtman, Judith H. ;
Lisabeth, Lynda D. ;
Magid, David ;
Marcus, Gregory M. ;
Marelli, Ariane ;
Matchar, David B. ;
McGuire, Darren K. ;
Mohler, Emile R. ;
Moy, Claudia S. ;
Mussolino, Michael E. ;
Nichol, Graham ;
Paynter, Nina P. ;
Schreiner, Pamela J. ;
Sorlie, Paul D. ;
Stein, Joel ;
Turan, Tanya N. ;
Virani, Salim S. ;
Wong, Nathan D. ;
Woo, Daniel ;
Turner, Melanie B. .
CIRCULATION, 2013, 127 (01) :E6-E245
[9]   Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: Comparison with intravascular ultrasound [J].
Jang, IK ;
Bouma, BE ;
Kang, DH ;
Park, SJ ;
Park, SW ;
Seung, KB ;
Choi, KB ;
Shishkov, M ;
Schlendorf, K ;
Pomerantsev, E ;
Houser, SL ;
Aretz, HT ;
Tearney, GJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (04) :604-609
[10]   Effects of MnO doping on properties of 0.97K0.5Na0.5NbO3-0.03(Bi0.5K0.5)TiO3 piezoelectric ceramics [J].
Jiang, X. P. ;
Chen, Y. ;
Lam, K. H. ;
Choy, S. H. ;
Wang, J. .
JOURNAL OF ALLOYS AND COMPOUNDS, 2010, 506 (01) :323-326