AMS 700™ inflatable penile prosthesis with InhibiZone®

被引:2
作者
McKim, Stephen E. [1 ]
Carson, Culley C., III [1 ]
机构
[1] Univ N Carolina, Div Urol, Chapel Hill, NC 27599 USA
关键词
AMS 700 (TM); biofilm; erectile dysfunction; InhibiZone (R); penile prosthesis; CENTRAL VENOUS CATHETERS; MECHANICAL RELIABILITY; INFECTION; IMPLANTS; EFFICACY; COLONIZATION; MINOCYCLINE; RIFAMPIN; SATISFACTION; MULTICENTER;
D O I
10.1586/ERD.10.6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Inflatable penile prostheses are the definitive therapy for erectile dysfunction refractory to medical therapy. For years mechanical malfunction was the most common cause of device failure, but recent advances in design have largely eliminated this, and now infection is the most significant problem with these implants. Antibiotic-coated medical devices, such as central venous and bladder catheters, have proven effective in reducing bacterial colonization and biofilm formation, leading to decreased rates of infection. In 2001, American Medical Systems (AMS) released its AMS 700 (TM) series penile prosthesis impregnated with a proprietary combination of the antibiotics rifampin and minocycline, called InhibiZone (R). Multiple studies have found that this device significantly reduces infection rates in men receiving penile prostheses. In July 2009, the US FDA approved the AMS 700 with InhibiZone as the only inflatable penile prosthesis with clinical evidence showing significant reduction in the rate of revision surgery due to infection.
引用
收藏
页码:311 / 317
页数:7
相关论文
共 30 条
[1]   Risk of infection with an antibiotic coated penile prosthesis at device replacement for mechanical failure [J].
Abouassaly, Robert ;
Angermeier, Kenneth W. ;
Montague, D. K. .
JOURNAL OF UROLOGY, 2006, 176 (06) :2471-2473
[2]  
Carson CC, 2004, J UROLOGY, V172, P781
[3]   LATE HEMATOGENOUS INFECTION OF PENILE PROSTHESES [J].
CARSON, CC ;
ROBERTSON, CN .
JOURNAL OF UROLOGY, 1988, 139 (01) :50-52
[4]  
CARSON CC, 2010, SE SECT AM UR ASS AN
[5]   Current concepts - Treatment of infections associated with surgical implants [J].
Darouiche, RO .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (14) :1422-1429
[6]   Efficacy of antimicrobial-impregnated bladder catheters in reducing catheter-associated bacteriuria: A prospective, randomized, multicenter clinical trial [J].
Darouiche, RO ;
Smith, JA ;
Hanna, H ;
Dhabuwala, CB ;
Steiner, MS ;
Babaian, RJ ;
Boone, TB ;
Scardino, PT ;
Thornby, JI ;
Raad, II .
UROLOGY, 1999, 54 (06) :976-981
[7]   Efficacy of anti microbial-impregnated silicone sections from penile implants in preventing device colonization in an animal model [J].
Darouiche, RO ;
Mansouri, MD ;
Raad, II .
UROLOGY, 2002, 59 (02) :303-307
[8]   Antimicrobial activity and durability of a novel antimicrobial-impregnated bladder catheter [J].
Darouiche, RO ;
Hampel, OZ ;
Boone, TB ;
Raad, II .
INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 1997, 8 (04) :243-247
[9]   A comparison of two antimicrobial-impregnated central venous catheters [J].
Darouiche, RO ;
Raad, II ;
Heard, SO ;
Thornby, JI ;
Wenker, OC ;
Gabrielli, A ;
Berg, J ;
Khardori, N ;
Hanna, H ;
Hachem, R ;
Harris, RL ;
Mayhall, G .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 340 (01) :1-8
[10]   ANTIBIOTIC SUSCEPTIBILITY OF STAPHYLOCOCCAL ISOLATES FROM PATIENTS WITH VASCULAR CATHETER-RELATED BACTEREMIA - POTENTIAL ROLE OF THE COMBINATION OF MINOCYCLINE AND RIFAMPIN [J].
DAROUICHE, RO ;
RAAD, II ;
BODEY, GP ;
MUSHER, DM .
INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 1995, 6 (01) :31-36