共 23 条
Biomechanical behavior of teeth without remaining coronal structure restored with different post designs and materials
被引:17
作者:
Maroli, Angelica
[1
]
Lotice Hoelcher, Kaue Andreas
[1
]
Reginato, Vagner Flavio
[1
,2
]
Spazzin, Aloisio Oro
[1
]
Caldas, Ricardo Armini
[2
]
Bacchi, Atais
[1
]
机构:
[1] Merid Fac IMED, Sch Dent, Passo Fundo, RS, Brazil
[2] Univ Estadual Campinas, FOP UNICAMP, Piracicaba Dent Sch, Piracicaba, SP, Brazil
来源:
MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS
|
2017年
/
76卷
关键词:
Endodontic treated tooth;
Intracanal post;
Tooth fracture strength;
Tooth FEM analysis;
Prediction of tooth fracture;
FINITE-ELEMENT-ANALYSIS;
RETAINED RESTORATIONS;
FRACTURE-RESISTANCE;
DENTIN;
STRENGTH;
FERRULE;
CROWN;
LENGTH;
SYSTEM;
GLASS;
D O I:
10.1016/j.msec.2017.03.152
中图分类号:
TB3 [工程材料学];
R318.08 [生物材料学];
学科分类号:
0805 ;
080501 ;
080502 ;
摘要:
The aim of this study was to access the biomechanical behavior of teeth without remaining coronal structure when restored with posts of different materials and configurations. Fifty bovine teeth (n = 10 per group) with standard dimensions were restored as follows: cast post and core (CPC), prefabricated metallic post (PFM), parallel glass-fiber post (P-FP), conical glass-fiber post (C-FP) or composite core (no post, CC). The survival rate during thermomechanical challenging (TC), the fracture strength (FS), and failure pattern (FP) were evaluated. Finite element models were realized to evaluate the stress distribution with a 100 N load. All post-containing teeth survived TC, while CC had 30% of failures. CPC and C-FP had the higher fracture strength, but a high number of irreparable fractures (60%), such as PFM (70%). Von Mises analysis has shown the maximum stresses into the canal in groups restored with metallic posts, while glass-fiber posts and CC presented the maximum stresses at load contact point in the crown. CPC led to higher modified von Mises (mvM) stress in the cervical third of dentin. However, mvM values did not reach the dentin fracture limit for any group. Analysis of maximal contact pressure has shown better stress distribution along with the dentin interface in post-containing groups, especially for CPC. (C) 2017 Elsevier B.V. All rights reserved.