Influence of electrode configuration on energy utilization for SO2 removal in flue gas with pulsed corona plasma

被引:0
作者
Dong, BY [1 ]
Li, GF [1 ]
Wu, Y [1 ]
Li, J [1 ]
机构
[1] Dalian Univ Technol, Inst Electrostat & Special Power, Dalian 16024, Peoples R China
来源
CONFERENCE RECORD OF THE 2004 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-4: COVERING THEORY TO PRACTICE | 2004年
关键词
pulsed plasma; DeSO(2) of flue gas; reactor; electrode configuration; pulsed energy;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The reactor design is a critical factor for the power cost. In this paper, research has been focused on determining the optimization of the reactor design for improving pulsed streamer energy utilization efficiency and reducing power cost. The influence of electrode configuration on energy utilization efficiency of wire-plate DeSO(2) reactor has been studied. The experimental results show that energy utilization efficiency of reactor improves when increase the number of discharge wire or decrease the wire-to-plate spacing under same conditions such as the parameters of power supply circuit and DC high voltage, and the optimization wire-to-wire spacing is 0.6-1 times the size of the wire-to-plate spacing.
引用
收藏
页码:250 / 253
页数:4
相关论文
empty
未找到相关数据