Development of large area gamma-ray camera with GSO(Ce) scintillator arrays and PSPMTs

被引:23
作者
Nishimura, H.
Hattori, K.
Kabuki, S.
Kubo, H.
Miuchi, K.
Nagayoshi, T.
Okada, Y.
Orito, R.
Sekiya, H.
Takada, A.
Takeda, A.
Tanimori, T.
Ueno, K.
机构
[1] Kyoto Univ, Grad Sch Sci, Dept Phys, Sakyo Ku, Kyoto 6068802, Japan
[2] Waseda Univ, Adv Res Inst Sci & Engn, Shinjuku Ku, Tokyo 1620044, Japan
[3] Kobe Univ, Grad Sch Sci & Technol, Dept Phys, Kobe, Hyogo 6578501, Japan
[4] Univ Tokyo, ICRR, Kamioka Observ, Hida Shi, Gifu 5061205, Japan
基金
日本科学技术振兴机构;
关键词
GSO(Ce); gamma-ray camera; PSPMTs; FLAT-PANEL PMT; PERFORMANCE; DETECTOR;
D O I
10.1016/j.nima.2006.11.029
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have developed a position-sensitive scintillation camera with a large area as an absorber of an advanced Compton gamma-ray camera. At first we tested GSO(Ce) crystals. We compared light output from the GSO(Ce) crystals under various conditions: the method of surface polishing, the concentration of Ce, and co-doping Zr. As a result, we chose the GSO(Ce) crystals doped only 0.5 mol% Ce, surface of which was polished by chemical etching for the scintillator of our camera. We also made a 16 x 16 cm? scintillation camera which consisted of nine position-sensitive PMTS (PSPMTs Hamamatsu flat-panel H8500), the each of which had 8 x 8 anodes with a pitch of 6 mm and coupled to 8 x 8 arrays of pixelated 6 x 6 x 13 mm(3) GSO(Ce) scintillators. For the readout system of 576 anodes of the PMTS, we used chained resistors to reduce the number of readout channels down to 48 for saving power consumption. The camera has the position resolution of less than 6 mm and a typical energy resolution of 10.5% (FWHM) at 662 keV at each pixel in a large area of 16 x 16 cm(2). Furthermore, we constructed a 16 x 16 array of 3 x 3 x 13 mm(3) pixelated GSO(Ce) scintillators, and glued it to a PMT H8500. This camera had the position resolution of less than 3 mm in area of 5 x 5 cm(2), except for some of edge pixels; the energy resolution was typically 13% (FWHM) at 662 keV. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:115 / 118
页数:4
相关论文
共 10 条
  • [1] [Anonymous], 2005, HAMAMATSU TECHNICAL
  • [2] Medium field of view multiflat panel-based portable gamma camera
    Giménez, M
    Benlloch, JM
    Cerdá, J
    Escat, B
    Fernández, M
    Giménez, EN
    Lerche, CW
    Martínez, JD
    Mora, FJ
    Pavón, N
    Sánchez, F
    Sebastià, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 525 (1-2) : 298 - 302
  • [3] A comparison of the imaging performance of different PSPMTs for PET applications
    Herbert, D
    Belcari, N
    Camarda, M
    Del Guerra, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 518 (1-2) : 399 - 400
  • [4] *HITACHI, 2005, 4413 HITACHI
  • [5] Performance of 256ch flat panel PS-PMT with small crystals for a DOI PET detector
    Inadama, N
    Murayama, H
    Watanabe, M
    Omura, T
    Yamashita, T
    Kawai, H
    Orita, N
    Tsuda, T
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (01) : 15 - 20
  • [6] Surface polishing of GSO scintillator using chemical process
    Kurashige, K
    Kurata, Y
    Ishibashi, H
    Susa, K
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 522 - 524
  • [7] Imaging detector designs based on flat panel PMT
    Pani, R
    Pellegrini, R
    Cinti, MN
    Trotta, C
    Bennati, P
    Cusanno, F
    Garibaldi, F
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 527 (1-2) : 54 - 57
  • [8] A novel compact gamma camera based on flat panel PMT
    Pani, R
    Pellegrini, R
    Cinti, MN
    Trotta, C
    Trotta, G
    Scafè, R
    Betti, M
    Cusanno, F
    Montani, L
    Iurlaro, G
    Garibaldi, F
    Del Guerra, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 513 (1-2) : 36 - 41
  • [9] Studies of the performance of different front-end systems for flat-panel multi-anode PMTs with CsI(T1) scintillator arrays
    Sekiya, H
    Hattori, K
    Kubo, H
    Miuchi, K
    Nagayoshi, T
    Nishimura, H
    Okada, Y
    Orito, R
    Takada, A
    Takeda, A
    Tanimori, T
    Ueno, K
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 563 (01) : 49 - 53
  • [10] Development of an advanced Compton camera with gaseous TPC and scintillator
    Takada, A
    Hattori, K
    Kubo, H
    Miuchi, K
    Nagayoshi, T
    Nishimura, H
    Okada, Y
    Orito, R
    Sekiya, H
    Tada, A
    Tanimori, T
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 546 (1-2) : 258 - 262