Differential pulse voltammetric determination of fenobucarb at the glassy carbon electrode, after its alkaline hydrolysis to a phenolic product

被引:11
作者
Cabanillas, AG [1 ]
Diaz, TG [1 ]
Salinas, F [1 ]
Ortiz, JM [1 ]
Kauffmann, JM [1 ]
机构
[1] FREE UNIV BRUSSELS,LAB INSTRUMENTAL ANAL & BIOELECTROCHEM,INST PHARMACEUT,ULB 205 6,B-1050 BRUSSELS,BELGIUM
关键词
fenobucarb; pesticides; differential pulse voltammetry;
D O I
10.1002/elan.1140091218
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A differential pulse voltammetric method for the determination of fenobucarb is proposed. This N-methylcarbamate pesticide is hydrolyzed in alkaline medium (0.02 M NaOH during ten min), and the resulting product 2 sec-butylphenol is oxidized at the glassy carbon electrode giving rise to a peak at a potential near 750 mV (pH 3.5). The linear relationship between I-p and fenobucarb concentration was established up to 1.00 x 10(-4) M concentration, the detection limit was 3.68 x 10(-6) M. The RSD is 3.74 % for a 1.0 x 10(-5) M concentration (n = 11, p = 0.05). The method has been satisfactorily applied to the analysis of water samples spiked with the pesticide.
引用
收藏
页码:952 / 955
页数:4
相关论文
共 21 条
[1]   DETERMINATION OF NONVOLATILE ORGANIC-COMPOUNDS IN AQUEOUS ENVIRONMENTAL-SAMPLES USING LIQUID CHROMATOGRAPHY/MASS SPECTROMETRY [J].
BELLAR, TA ;
BUDDE, WL .
ANALYTICAL CHEMISTRY, 1988, 60 (19) :2076-2083
[2]   DETERMINATION OF METHYL CARBAMATE RESIDUES USING ONLINE COUPLING OF HPLC WITH A POST COLUMN FLUOROMETRIC LABELING TECHNIQUE [J].
BLASS, W .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1991, 339 (06) :340-343
[3]   DETECTION LIMITS WITH SPECIFIED ASSURANCE PROBABILITIES [J].
CLAYTON, CA ;
HINES, JW ;
ELKINS, PD .
ANALYTICAL CHEMISTRY, 1987, 59 (20) :2506-2514
[4]  
DEKOK A, 1992, J CHROMATOGR, V623, P265
[5]   MICELLAR FLUORESCENCE ENHANCEMENT OF CARBAMATE PESTICIDES [J].
DELAGUARDIA, M ;
HERNANDEZ, ML ;
SANCENON, S ;
CARRION, JL .
COLLOIDS AND SURFACES, 1990, 48 (1-3) :57-64
[6]   FLOW-THROUGH SENSOR FOR THE DIRECT DETERMINATION OF PESTICIDE MIXTURES WITHOUT CHROMATOGRAPHIC-SEPARATION [J].
FERNANDEZBAND, B ;
LINARES, P ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1672-1675
[7]   DETERMINATION OF CARBARYL IN PESTICIDE FORMULATIONS BY FOURIER-TRANSFORM INFRARED SPECTROMETRY WITH FLOW-ANALYSIS [J].
GALLIGNANI, M ;
GARRIGUES, S ;
MARTINEZVADO, A ;
DELAGUARDIA, M .
ANALYST, 1993, 118 (08) :1043-1048
[8]   INDIRECT VOLTAMMETRIC DETERMINATION OF CARBARYL AND CARBOFURAN USING PARTIAL LEAST-SQUARES CALIBRATION [J].
GUIBERTEAU, A ;
DIAZ, TG ;
SALINAS, F ;
ORTIZ, JM .
ANALYTICA CHIMICA ACTA, 1995, 305 (1-3) :219-226
[9]   SIMPLE, RAPID AND SIMULTANEOUS MEASUREMENT OF 8 DIFFERENT TYPES OF CARBAMATE PESTICIDES IN SERUM USING LIQUID-CHROMATOGRAPHY ATMOSPHERIC-PRESSURE CHEMICAL-IONIZATION MASS-SPECTROMETRY [J].
KAWASAKI, S ;
NAGUMO, F ;
UEDA, H ;
TAJIMA, Y ;
SANO, M ;
TADANO, J .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 620 (01) :61-71
[10]  
KRAUSE RT, 1989, J ASSOC OFF ANA CHEM, V67, P1114