Composite photopolymerization with diode laser

被引:19
作者
Knezevic, A.
Ristic, M.
Demoli, N.
Tarle, Z.
Music, S.
Negovetic Mandic, V.
机构
[1] Univ Zagreb, Dept Endodont & Restorat Dent, Sch Dent Med, Zagreb 41000, Croatia
[2] Rudjer Boskovic Inst, Zagreb, Croatia
[3] Inst Phys, Zagreb, Croatia
关键词
D O I
10.2341/06-79
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Under clinical conditions, the time needed for the proper light curing of luting composites or the multi-incremental buildup of a large restoration with halogen curing units is quite extensive. Due to the development of high power curing devices, such as argon lasers and plasma arc lights and, in order to decrease curing time, halogen and LED devices have developed a high intensity polymerization mode. This study compared the degree of conversion using Fourier Transform Infrared Spectroscopy (FT-IR) of two composite materials: Tetric Ceram and Tetric EvoCeram. polymerized with three polymerization modes (high, low and soft mode) of a Bluephase 16i LED curing unit and blue diode laser intensity of 50 mW on the output of the laser beam and 35 mW/cm(2) on the resin composite sample. Descriptive statistic, t-test, ANOVA, Pearson Correlation and Tukey Post hoe tests were used for statistical analyses. The results show a higher degree of conversion for the polymerization of composite samples with all photopolymerization modes of the LED curing unit. However, there is no significant difference in the degree of conversion between the LED unit and 50-second polymerization with the blue diode laser. Tetric EvoCeram. shows a lower degree of conversion regardless of the polymerization mode (or light source) used.
引用
收藏
页码:279 / 284
页数:6
相关论文
共 21 条
[1]   Digital interferometry for measuring of the resin composite thickness variation during blue light polymerization [J].
Demoli, N ;
Knezevic, A ;
Tarle, Z ;
Meniga, A ;
Sutalo, J ;
Pichler, G .
OPTICS COMMUNICATIONS, 2004, 231 (1-6) :45-51
[2]  
Fleming M G, 1999, J Can Dent Assoc, V65, P447
[3]   Depth of cure and compressive strength of dental composites cured with blue light emitting diodes (LEDs) [J].
Jandt, KD ;
Mills, RW ;
Blackwell, GB ;
Ashworth, SH .
DENTAL MATERIALS, 2000, 16 (01) :41-47
[4]   Photopolymerization of composite resins with plasma light [J].
Knezevic, A ;
Tarle, Z ;
Meniga, A ;
Sutalo, J ;
Pichler, G ;
Ristic, M .
JOURNAL OF ORAL REHABILITATION, 2002, 29 (08) :782-786
[5]   Degree of conversion and temperature rise during polymerization of composite resin samples with blue diodes [J].
Knezevic, A ;
Tarle, Z ;
Meniga, A ;
Sutalo, J ;
Pichler, G ;
Ristic, M .
JOURNAL OF ORAL REHABILITATION, 2001, 28 (06) :586-591
[6]  
Knezevic A, 2005, ACTA STOMATOL CROAT, V39, P427
[7]   Hardness evaluation of a dental composite polymerized with experimental LED-based devices [J].
Kurachi, C ;
Tuboy, AM ;
Magalhaes, DV ;
Bagnato, VS .
DENTAL MATERIALS, 2001, 17 (04) :309-315
[8]  
Loney RW, 2001, OPER DENT, V26, P516
[9]   Pulsed blue laser curing of hybrid composite resins [J].
Meniga, A ;
Tarle, Z ;
Ristic, M ;
Sutalo, J ;
Pichler, G .
BIOMATERIALS, 1997, 18 (20) :1349-1354
[10]  
Obici Andresa Carla, 2004, Braz. Dent. J., V15, P199, DOI 10.1590/S0103-64402004000300007