Reduction of polyatomic interferences in biological material using dynamic reaction cell ICP-MS

被引:83
作者
Pick, Denis [1 ]
Leiterer, Matthias [2 ]
Einax, Juergen W. [1 ]
机构
[1] Univ Jena, Inst Inorgan & Analyt Chem, Dept Environm Anal, D-07743 Jena, Germany
[2] Agr Inst Invest & Res Thuringia, D-07743 Jena, Germany
关键词
Dynamic reaction cell ICP-MS; Polyatomic interference; Animal feedstuff; Plant material; Methane; Oxygen; INDUCTIVELY-COUPLED PLASMA; MASS-SPECTROMETRY; TOTAL SELENIUM; RESOLUTION; CHROMIUM; SAMPLES; OXIDE; IRON;
D O I
10.1016/j.microc.2010.01.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An analytical method is described for the routine quantification of five elements (As, Cr, Fe, Ni, and Sc) in plants and animal feedstuffs using dynamic reaction cell inductively coupled plasma mass spectrometry (ICP-DRC-MS) after microwave digestion Methane (for Cr. Fe, Ni, and Sc) and oxygen (for As) were used as reaction gases to reduce polyatomic interferences. Optimization of the gas flow rate and the quadrupole dynamic bandpass tuning parameter (RPq) was carried out for the method Detection limits (LOD) were in the range of 003-0 65 mu g L-1 and were significantly lower compared to the standard mode without DRC The trueness of the method was tested using three reference materials from Round robin tests Results were well in accordance with the certified values. Furthermore, DRC data were examined by analyzing the same samples using sector field ICP-MS (SF-ICP-MS) and an ICP-MS equipped with collision cell technology (ICP-CCT-MS) The data obtained were in the confidence range of the reference material, too The investigated method was applied for the analysis of grass and corn silage samples (C) 2010 Elsevier B V. All rights reserved
引用
收藏
页码:315 / 319
页数:5
相关论文
共 25 条
[1]  
[Anonymous], 2008, DIN 32645:2008-11
[2]  
[Anonymous], 2004, Elements and their Compounds in the Environment
[3]   Gas-phase ion-molecule reactions for resolution of atomic isobars: AMS and ICP-MS perspectives [J].
Bandura, Dmitry R. ;
Baranov, Vladimir I. ;
Litherland, A. E. ;
Tanner, Scott D. .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2006, 255 :312-327
[4]   Analysis of Ling Zhi (Ganoderma lucidum) using dynamic reaction cell ICP-MS and ICP-AES [J].
Chan, YY ;
Lo, SCL .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (02) :146-150
[5]   Determination of calcium, iron and zinc in milk powder by reaction cell inductively coupled plasma mass spectrometry [J].
Chen, KL ;
Jiang, SJ .
ANALYTICA CHIMICA ACTA, 2002, 470 (02) :223-228
[6]   Determination of trace elements in serum by dynamic reaction cell inductively coupled plasma mass spectrometry - Developing of a method with a desolvating system nebulizer [J].
D'Ilio, S. ;
Violante, N. ;
Caimi, S. ;
Di Gregorio, M. ;
Petrucci, F. ;
Senofonte, O. .
ANALYTICA CHIMICA ACTA, 2006, 573 :432-438
[7]   Simultaneous quantification of 17 trace elements in blood by dynamic reaction cell inductively coupled plasma mass spectrometry (DRC-ICP-MS) equipped with a high-efficiency sample introduction system [J].
D'Ilio, S. ;
Violante, N. ;
Di Gregorio, M. ;
Senofonte, O. ;
Petrucci, F. .
ANALYTICA CHIMICA ACTA, 2006, 579 (02) :202-208
[8]   Determination of chromium, iron and selenium in foodstuffs of animal origin by collision cell technology, inductively coupled plasma mass spectrometry (ICP-MS), after closed vessel microwave digestion [J].
Dufailly, V ;
Noël, L ;
Guérin, T .
ANALYTICA CHIMICA ACTA, 2006, 565 (02) :214-221
[9]   INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY - A REVIEW [J].
EVANS, EH ;
GIGLIO, JJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (01) :1-18
[10]   Strategies for method development for an inductively coupled plasma mass spectrometer with bandpass reaction cell.: Approaches with different reaction gases for the determination of selenium [J].
Hattendorf, B ;
Günther, D .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (01) :1-13