Goldmann Tonometry Correction Factors Based on Numerical Analysis

被引:12
作者
Elsheikh, Ahmed [1 ]
Alhasso, Daad [1 ]
Pye, David [2 ]
机构
[1] Univ Dundee, Div Civil Engn, Dundee DD1 4HN, Scotland
[2] Univ New S Wales, Sch Optometry & Vis Sci, Sydney, NSW 2052, Australia
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2009年 / 131卷 / 11期
关键词
tonometry; intra-ocular pressure; cornea; numerical modeling; CENTRAL CORNEAL THICKNESS; DYNAMIC CONTOUR TONOMETRY; INTRAOCULAR-PRESSURE; APPLANATION TONOMETRY; BIOMECHANICAL PROPERTIES; DIURNAL-VARIATION; KERATOCONUS; COLLAGEN; ASSOCIATION; ORIENTATION;
D O I
10.1115/1.4000112
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
With the world's aging population, it is expected that the number of people affected by glaucoma, the second most common cause of irreversible blindness, will increase considerably. Current knowledge on glaucoma progression relates elevation of the intraocular pressure (IOP) to optic nerve damage and hence visual impairment. For this reason, IOP measurement in tonometry has become an essential part of routine eye examinations needed for the diagnosis and management of the disease. The accuracy of the current reference standard in tonometry, the Goldmann applanation tonometer is known to be affected by the natural variations in corneal thickness, curvature, and material properties. Earlier studies attempted to quantify these effects and produced correction factors that considered the variations in each one of these parameters separately, and no guidance was given as to how to combine the effects of variations in more than one parameter The present research attempted to address this gap by conducting a multidimensional numerical study that considered variations in thickness, curvature, material properties, and IOP and used the results to develop a single correction equation that considered these parameters simultaneously. The results of the analysis and the correction equation were validated successfully against the outcome of earlier clinical and mathematical studies on the effect of individual parameters, and the correction equation was presented in a simple form suitable for clinical application. [DOI: 10.1115/1.4000112]
引用
收藏
页数:9
相关论文
共 42 条
[1]   BIOMECHANICAL PROPERTIES OF KERATOCONUS AND NORMAL CORNEAS [J].
ANDREASSEN, TT ;
SIMONSEN, AH ;
OXLUND, H .
EXPERIMENTAL EYE RESEARCH, 1980, 31 (04) :435-441
[2]   Comparison of dynamic contour tonometry and Goldmann applanation tonometry in glaucoma patients and healthy subjects [J].
Barleon, Lorenz ;
Hoffmann, Esther M. ;
Berres, Manfred ;
Pfeiffer, Norbert ;
Grus, Franz H. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 142 (04) :583-590
[3]  
BRYANT MR, 1994, INVEST OPHTH VIS SCI, V35, P3022
[4]  
Daxer A, 1997, INVEST OPHTH VIS SCI, V38, P121
[5]   Radius and asphericity of the posterior corneal surface determined by corrected Scheimpflug photography [J].
Dubbelman, M ;
Weeber, HA ;
van der Heijde, RGL ;
Völker-Dieben, HJ .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 2002, 80 (04) :379-383
[6]  
EHLERS N, 1975, ACTA OPHTHALMOL, V53, P34
[7]   Numerical modelling of corneal biomechanical behaviour [J].
Elsheikh, Ahmed ;
Wang, Defu .
Computer Methods in Biomechanics and Biomedical Engineering, 2007, 10 (02) :85-95
[8]   Experimental assessment of human corneal hysteresis [J].
Elsheikh, Ahmed ;
Wang, Defu ;
Rama, Paolo ;
Campanelli, Marino ;
Garway-Heath, David .
CURRENT EYE RESEARCH, 2008, 33 (03) :205-213
[9]   Assessment of corneal biomechanical properties and their variation with age [J].
Elsheikh, Ahmed ;
Wang, Defu ;
Brown, Michael ;
Rama, Paolo ;
Campanelli, Marino ;
Pye, David .
CURRENT EYE RESEARCH, 2007, 32 (01) :11-19
[10]   Evaluation of goldmann applanation tonometry using a nonlinear finite element ocular model [J].
Elsheikh, Ahmed ;
Wang, Defu ;
Kotecha, Aachal ;
Brown, Michael ;
Garway-Heath, David .
ANNALS OF BIOMEDICAL ENGINEERING, 2006, 34 (10) :1628-1640