共 50 条
Conduction Disturbance, Pacemaker Rates, and Hospital Length of Stay Following Transcatheter Aortic Valve Implantation with the Sapien 3 Valve
被引:2
作者:
Isogai, Toshiaki
[1
]
Shekhar, Shashank
[1
]
Saad, Anas M.
[1
]
Abdelfattah, Omar M.
[1
]
Tarakji, Khaldoun G.
[1
]
Wazni, Oussama M.
[1
]
Kalra, Ankur
[1
]
Yun, James J.
[1
]
Krishnaswamy, Amar
[1
]
Reed, Grant W.
[1
]
Kapadia, Samir R.
[1
]
Puri, Rishi
[1
]
机构:
[1] Cleveland Clin, Dept Cardiovasc Med, Heart Vasc & Thorac Inst, 9500 Euclid Ave,J2-3, Cleveland, OH 44195 USA
来源:
STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM
|
2022年
/
6卷
/
03期
关键词:
Complete heart block;
Length of stay;
Permanent pacemaker;
Temporary pacemaker;
Transcatheter aortic valve implantation;
NEXT-DAY-DISCHARGE;
CLINICAL-OUTCOMES;
REPLACEMENT;
PREDICTORS;
ELECTROCARDIOGRAM;
MANAGEMENT;
CARDIOLOGY;
PATHWAY;
TRENDS;
BLOCK;
D O I:
10.1016/j.shj.2022.100019
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
Background: In the absence of randomized data, an expert panel recently proposed an algorithm for conduction disturbance management in transcatheter aortic valve implantation (TAVI) recipients. However, external vali-dations of its recommendations are limited. Methods: We retrospectively identified 808 patients without a pre-existing pacing device who underwent trans -femoral TAVI with the Sapien 3 valve at our institution in 2018-2019. Patients were grouped based on pre-existing conduction disturbance and immediate post-TAVI electrocardiogram. Timing of temporary pacemaker (TPM) removal and hospital discharge were compared with those of the expert panel recommendations to evaluate the associated risk of TPM reinsertion and permanent pacemaker (PPM) implantation. Results: In most group 1 patients (no electrocardiogram changes without pre-existing right bundle branch block), the timing of TPM removal and discharge were concordant with those of the expert panel recommendations, with low TPM reinsertion (0.8%) and postdischarge PPM (0.8%) rates. In the majority of group 5 patients (procedural high-degree/complete atrioventricular block), TPM was maintained, followed by PPM implantation, compatible with the expert panel recommendations. In contrast, in groups 2-4 (pre-existing/new conduction disturbances), earlier TPM removal than recommended by the expert panel (mostly, immediately after procedure) was feasible in 97.5%-100% of patients, with a low TPM reinsertion rate (0.0%-1.8%); earlier discharge was also feasible in 50.0%-65.5%, with a low 30-day postdischarge PPM rate (0.0%-2.8%) and no 30-day death. Conclusions: Early TPM removal and discharge after TAVI appear safe and feasible in the majority of cases. These data may provide a framework for an early, streamlined hospital discharge plan for TAVI recipients, optimizing both cost savings and patient safety.
引用
收藏
页数:10
相关论文
共 50 条