Multi-zonal air flow rates in residences in Boston, Massachusetts

被引:25
作者
Dodson, Robin E. [1 ]
Levy, Jonathan I. [1 ]
Shine, James P. [1 ]
Spengler, John D. [1 ]
Bennett, Deborah H. [1 ]
机构
[1] Harvard Univ, Sch Publ Hlth, Dept Environm Hlth, Boston, MA 02115 USA
关键词
attached garages; basement; apartment; mass-balance model; air flow rates;
D O I
10.1016/j.atmosenv.2007.01.035
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In spite of the importance of interzonal air flow for indoor air quality assessment, few studies have characterized these flows. As part of the Boston Exposure Assessment in Microenvironments (BEAM) Study, air flow rates were estimated within 45 residences in the Boston area, most over two seasons. Thirty-five residences had basements, I I of which also had attached garages, and 10 other residences had common apartment hallways. Air flow rates between zones were calculated using tracer gases (PFTs and SF6) and mass-balance models. Mean air flow rates from the basement to the occupied zone were significantly higher in the winter (174 m(3) h(-1)) than in the summer (67 m(3) h(-1)). The mean percent of the total air flow within the occupied zone of the residence from the basement was 26% (SD = 34%) in the summer and 47% (SD = 26%) in the winter while the mean percent from apartment hallways was 22% (SD = 33%). Residences with garages attached to the basement had higher air flow rates to the adjacent zone (means from 50 to 887 m(3) h(-1)) than those with garages attached directly to the occupied zone (means from 1 to 65 m(3) h(-1)). These data provide a basis for modeling the contribution of indoor sources to concentrations in occupied zones. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3722 / 3727
页数:6
相关论文
共 13 条
[1]   Simultaneous measurement of ventilation using tracer gas techniques and VOC concentrations in homes, garages and vehicles [J].
Batterman, S ;
Jia, CR ;
Hatzivasilis, G ;
Godwin, C .
JOURNAL OF ENVIRONMENTAL MONITORING, 2006, 8 (02) :249-256
[2]  
DIAMOND RC, 1996, VENTILATION INFILTRA
[3]  
Dietz RN., 1982, ENVIRON INT, V8, P419, DOI DOI 10.1016/0160-4120(82)90060-5
[4]   Bayesian curve-fitting with free-knot splines [J].
DiMatteo, I ;
Genovese, CR ;
Kass, RE .
BIOMETRIKA, 2001, 88 (04) :1055-1071
[5]  
Emmerich S.J., 2003, Int. J. Vent, V2, P265, DOI DOI 10.1080/14733315.2003.11683670
[6]  
GRAHAM L, 1999, INDOOR AIR SAMPLING
[7]   Indoor climate in interior Alaska: simultaneous measurement of ventilation, benzene and toluene in residential indoor air of two homes [J].
Isbell, MA ;
Stolzberg, RJ ;
Duffy, LK .
SCIENCE OF THE TOTAL ENVIRONMENT, 2005, 345 (1-3) :31-40
[8]   3-DIMENSIONAL SIMULATION OF RADON TRANSPORT INTO HOUSES WITH BASEMENTS UNDER CONSTANT NEGATIVE-PRESSURE [J].
LOUREIRO, CO ;
ABRIOLA, LM ;
MARTIN, JE ;
SEXTRO, RG .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1990, 24 (09) :1338-1348
[9]  
MCGRATH P, 1996, BUILDING SERVICES EN, V17
[10]   RADON TRANSPORT INTO A DETACHED ONE-STORY HOUSE WITH A BASEMENT [J].
NAZAROFF, WW ;
FEUSTEL, H ;
NERO, AV ;
REVZAN, KL ;
GRIMSRUD, DT ;
ESSLING, MA ;
TOOHEY, RE .
ATMOSPHERIC ENVIRONMENT, 1985, 19 (01) :31-46