Analysis of fault current contribution of Doubly-Fed Induction Generator Wind Turbines during unbalanced grid faults

被引:23
作者
El-Naggar, Ahmed [1 ]
Erlich, Istvan [1 ]
机构
[1] Duisburg Essen Univ, D-47057 Duisburg, Germany
关键词
Wind turbine; Doubly-fed induction generator; Short-circuit current; Unbalanced fault; Negative sequence;
D O I
10.1016/j.renene.2016.01.045
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The fault current contribution of the Doubly-Fed Induction Generator Wind Turbines (DFIG-WTs) under unbalanced grid faults did not draw researchers' attention due to the absence of any related requirements in the former grid codes. However, in 2015 new requirements were established dictating the DFIG-WT/generating unit to remain connected to the grid during phase-to-phase short-circuit and to perform reactive power provision. Thereupon, the knowledge of the fault current magnitude as well as the dynamic response of the DFIG-WT are crucial for the power system component design and for the validation of its commitment to the grid codes requirements. There are concrete control objectives regarding negative sequence control that cannot be fulfilled simultaneously but rather set according to the owner's preferences. Therefore, in this paper, a detailed analysis of the negative sequence current response under each control objective were carried out, considering all the controller parameters. The influence of each controller structure on the short-circuit quantities is investigated and based on it an approximated mathematical models of the short-circuit quantities and currents were proposed. Finally, a brief analysis, due to space limitation, of the response during the voltage limitation period is also performed where the influences of voltage limitation on the negative sequence current were shown. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:137 / 146
页数:10
相关论文
共 29 条
  • [21] He YK, 2008, ICEMS 2008: PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1- 8, P2331
  • [22] Klein F., 1888, LECT IKOSAHEDRON SOL
  • [23] LE TN, 1989, ETZ ARCHIV, V11, P249
  • [24] Feedforward Transient Compensation Control for DFIG Wind Turbines During Both Balanced and Unbalanced Grid Disturbances
    Liang, Jiaqi
    Howard, Dustin F.
    Restrepo, Jose A.
    Harley, Ronald G.
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2013, 49 (03) : 1452 - 1463
  • [25] Rotor Voltage Dynamics in the Doubly Fed Induction Generator During Grid Faults
    Lima, Francisco K. A.
    Luna, Alvaro
    Rodriguez, Pedro
    Watanabe, Edson H.
    Blaabjerg, Frede
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2010, 25 (01) : 118 - 130
  • [26] Martinez J., 2011, POWER SYSTEMS C EXPO, P1
  • [27] Short-circuit current of wind turbines with doubly fed induction generator
    Morren, Johan
    de Haan, Sjoerd W. H.
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (01) : 174 - 180
  • [28] Ride-through analysis of doubly fed induction wind-power generator under unsymmetrical network disturbance
    Seman, Slavomir
    Niiranen, Jouko
    Arkkio, Antero
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2006, 21 (04) : 1782 - 1789
  • [29] Yasa Y, 2013, APPL POWER ELECT CO, P2953, DOI 10.1109/APEC.2013.6520718