Analysis and removal of the stench emitted from indoor dust

被引:2
作者
Kim, Yeon-Hong [1 ,2 ]
Jung, Hana [1 ,2 ]
Changshin, Sunwoo [3 ]
Kim, Do-Heyoung [1 ,2 ]
机构
[1] Chonnam Natl Univ, Sch Appl Chem Engn, BK Program 21, Ctr Funct Nano Fine Chem,Coll Engn, Kwangju 500757, South Korea
[2] Chonnam Natl Univ, Res Inst Catalyst, Kwangju 500757, South Korea
[3] Chonnam Natl Univ, Sch Biol Sci & Technol, Kwangju 500757, South Korea
关键词
Olfactory Method; Dust; Stench; Odor Measurement; GC-MS; THRESHOLD DILUTION RATIO; ODOR; OLFACTOMETRY; INTENSITY;
D O I
10.1007/s11814-010-0114-x
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The offensive odor produced from indoor dust accumulated inside a vacuum cleaner is quite unpleasant to the user. In this study, the odor of dust samples prepared under various conditions was examined using an olfactory method that employs the human sense of smell. In addition, the odorous compounds were analyzed by GC-MS. The odor intensity of the dust collected inside the vacuum cleaner increased in proportion to not only the humidity and temperature of the dust, but also to the cleaning period of the container where indoor dust was accumulated. GC/MS confirmed aldehydes to be the main odorous compounds. The dilution ratio at which the stench of the indoor dust was not detected was determined by using the triangle odor bag method.
引用
收藏
页码:531 / 535
页数:5
相关论文
共 20 条
[1]   Odor as an Aid to Chemical Safety: Odor Thresholds Compared with Threshold Limit Values and Volatilities for 214 Industrial Chemicals in Air and Water Dilution [J].
Amoore, John E. ;
Hautala, Earl .
JOURNAL OF APPLIED TOXICOLOGY, 1983, 3 (06) :272-290
[2]  
*ASTM INT, 1981, STP, V758
[3]  
*ASTM INT, 1978, D139178 ASTM INT
[4]   Using olfactometry to measure intensity and threshold dilution ratio for evaluating swine odor [J].
Chen, YC ;
Bundy, DS ;
Hoff, SJ .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1999, 49 (07) :847-853
[5]   Development of the relationship between odor intensity and threshold dilution ratio for swine units [J].
Chen, YC ;
Bundy, DS ;
Hoff, SJ .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1999, 49 (09) :1082-1088
[6]  
CHO SH, 2006, SCI TOTAL ENVIRON, V31, P371
[7]   ODOR THRESHOLD MEASUREMENT BY DYNAMIC OLFACTOMETRY - SIGNIFICANT OPERATIONAL VARIABLES [J].
DRAVNIEKS, A ;
JARKE, F .
JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1980, 30 (12) :1284-1289
[8]   CHARACTERIZATION OF ODOR PROPERTIES OF 101 PETROCHEMICALS USING SENSORY METHODS [J].
HELLMAN, TM ;
SMALL, FH .
JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1974, 24 (10) :979-982
[9]   ASSESSMENT OF ODORS FROM LIVESTOCK WASTES BY A PHOTOIONIZATION DETECTOR, AN ELECTRONIC NOSE, OLFACTOMETRY AND GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
HOBBS, PJ ;
MISSELBROOK, TH ;
PAIN, BF .
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1995, 60 (02) :137-144
[10]  
Ishikawa Y., 2000, J ODOR RES ENG, V31, P6