A survey of physics and dosimetry practice of permanent prostate brachytherapy in the United States

被引:35
作者
Prete, JJ
Prestidge, BR
Bice, WS
Friedland, JL
Stock, RG
Grimm, PD
机构
[1] Wilford Hall USAF Med Ctr, Radiat Oncol PSRT, Dept Radiat Oncol, Lackland AFB, TX 78236 USA
[2] Univ Texas, Hlth Sci Ctr, Dept Radiol, Div Radiol Sci, San Antonio, TX 78284 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1998年 / 40卷 / 04期
关键词
prostate brachytherapy; physics and dosimetry practice; survey;
D O I
10.1016/S0360-3016(97)00901-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To obtain data with regard to current physics and dosimetry practice in transperineal interstitial permanent prostate brachytherapy (TIPPB) in the U.S. by conducting a survey of institutions performing this procedure with the greatest frequency. Methods and Materials: Seventy brachytherapists with the greatest volume of TIPPB cases in 1995 in the U.S. were surveyed. The four-page comprehensive questionnaire included questions on both clinical and physics and dosimetry practice. Individuals not responding initially were sent additional mailings and telephoned. Physics and dosimetry practice summary statistics are reported. Clinical practice data is reported separately. Results: Thirty-five (50%) surveys were returned. Participants included 29 (83%) from the private sector and 6 (17%) from academic programs. Among responding clinicians, I-125 (89%) is used with greater frequency than Pd-103 (83%). Many use both (71%). Most brachytherapists perform preplans (86%), predominately employing ultrasound imaging (85%). Commercial treatment planning systems are used more frequently (75%) than in-house systems (25%). Preplans take 2.5 h (avg.) to perform and are most commonly performed by a physicist (69%). A wide range of apparent activities (mCi) is used for both I-125 (0.16-1.00, avg. 0.41) and Pd-103 (0.50-1.90, avg. 1.32). Of those assaying sources (71%), the range in number assayed (1 to all) and maximum accepted difference from vendor stated activity (2-20%) varies greatly. Most respondents feel that the manufacturers criteria for source activity are sufficiently stringent (88%); however, some report that vendors do not always meet their criteria (44%). Most postimplant dosimetry imaging occurs on day 1 (41%) and consists of conventional x-rays (83%), CT (63%), or both (46%). Postimplant dosimetry is usually performed by a physicist (72%), taking 2 h (avg.) to complete, Calculational formalisms and parameters vary substantially. At the time of the survey, few institutions have adopted AAPM TG-43 recommendations (21%). Only half (50%) of those not using TG-43 indicated an intent to do so in the future. Calculated doses at 1 cm from a single 1 mCi apparent activity source permanently implanted varied significantly. For I-125, doses calculated ranged from 13.08-40.00 Gy and for Pd-103, from 3.10 to 8.70 Gy. Conclusion: While several areas of current physics and dosimetry practice are consistent among institutions, treatment planning and dose calculation techniques vary considerably. These data demonstrate a relative lack of consensus with regard to these practices. Furthermore, the wide variety of calculational techniques and benchmark data lead to calculated doses which vary by clinically significant amounts. It is apparent that the lack of standardization with regard to treatment planning and dose calculation practice in TIPPB must be addressed prior to performing any meaningful comparison of clinical results between institutions.
引用
收藏
页码:1001 / 1005
页数:5
相关论文
共 16 条
  • [1] [Anonymous], 1987, ENDOCURIETHER HYPERT
  • [2] BICE WS, IN PRESS INT J RAD O
  • [3] Blasko, 1993, Semin Radiat Oncol, V3, P240, DOI 10.1016/S1053-4296(05)80121-3
  • [4] PROSTATE-SPECIFIC ANTIGEN BASED DISEASE-CONTROL FOLLOWING ULTRASOUND-GUIDED (125)IODINE IMPLANTATION FOR STAGE T1/T2 PROSTATIC-CARCINOMA
    BLASKO, JC
    WALLNER, K
    GRIMM, PD
    RAGDE, H
    [J]. JOURNAL OF UROLOGY, 1995, 154 (03) : 1096 - 1099
  • [5] Pd-103 brachytherapy and external beam irradiation for clinically localized, high-risk prostatic carcinoma
    Dattoli, M
    Wallner, K
    Sorace, R
    Koval, J
    Cash, J
    Acosta, R
    Brown, C
    Etheridge, J
    Binder, M
    Brunelle, R
    Kirwan, N
    Sanchez, S
    Stein, D
    Wasserman, S
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (05): : 875 - 879
  • [6] TRANSPERINEAL I125 SEED IMPLANTATION IN PROSTATIC-CANCER GUIDED BY TRANS-RECTAL ULTRASONOGRAPHY
    HOLM, HH
    JUUL, N
    PEDERSEN, JF
    HANSEN, H
    STROYER, I
    [J]. JOURNAL OF UROLOGY, 1983, 130 (02) : 283 - 286
  • [7] TREATMENT-RELATED SYMPTOMS DURING THE 1ST YEAR FOLLOWING TRANSPERINEAL I-125 PROSTATE IMPLANTATION
    KLEINBERG, L
    WALLNER, K
    ROY, J
    ZELEFSKY, M
    ARTERBERY, VE
    FUKS, Z
    HARRISON, L
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (04): : 985 - 990
  • [8] TRANSPERINEAL PALLADIUM-103 PROSTATE BRACHYTHERAPY - ANALYSIS OF MORBIDITY AND SEED MIGRATION
    NAG, S
    SCAPEROTH, DD
    BADALAMENT, R
    HALL, SA
    BURGERS, J
    [J]. UROLOGY, 1995, 45 (01) : 87 - 92
  • [9] DOSIMETRY OF INTERSTITIAL BRACHYTHERAPY SOURCES - RECOMMENDATIONS OF THE AAPM RADIATION-THERAPY COMMITTEE TASK GROUP NO 43
    NATH, R
    ANDERSON, LL
    LUXTON, G
    WEAVER, KA
    WILLIAMSON, JF
    MEIGOONI, AS
    [J]. MEDICAL PHYSICS, 1995, 22 (02) : 209 - 234
  • [10] Posttreatment biopsy results following interstitial brachytherapy in early-stage prostate cancer
    Prestidge, BR
    Hoak, DC
    Grimm, PD
    Ragde, H
    Cavanagh, W
    Blasko, JC
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (01): : 31 - 39